BLD-Final | 3/20/2008 | 3/20/2008 | 3/20/2008 | P | PASS |
Tom Arcoraci
|
|
|
Phone #: ###-#### Internet Inspection Request from: Ken Litzinger
|
DOC - Permit Finaled | 3/20/2008 | 3/20/2008 | 3/20/2008 | P | PASS |
Tom Arcoraci
|
|
|
|
Code Occupancy Approval | 3/20/2008 | 3/20/2008 | 3/20/2008 | P | PASS |
Dena Gambrel
|
|
|
3-20-08 1022 Passed.
|
BLD-Energy code compliance | 1/28/2008 | 1/28/2008 | 1/28/2008 | P | PASS |
Tom Arcoraci
|
|
|
Please Call 1/2 hour before inspection...Thanks Phone #: ###-#### Internet Inspection Request from: Ken Litzinger
|
BLD-Framing/Rough-in | 1/28/2008 | 1/28/2008 | 1/28/2008 | P | PASS |
Tom Arcoraci
|
|
|
Please Call 1/2 hour before inspection...Thanks Phone #: ###-#### Internet Inspection Request from: Ken Litzinger
|
BLD-Framing/Rough-in | 1/22/2008 | 1/23/2008 | 1/23/2008 | A | FAIL |
Jim Storey
|
|
|
Phone #: ###-#### Internet Inspection Request from: Ken Litzinger front attic can not verify 1 hr wall thru space per plan/ justify bearing blk as built by engineering. ok to insulate.
|
BLD-Framing/Rough-in | 1/22/2008 | 1/22/2008 | 1/22/2008 | P | PART |
Jim Storey
|
|
|
Phone #: ###-#### Internet Inspection Request from: Ken Litzinger out of time.
|
BLD-Foundation | 11/15/2007 | 11/15/2007 | 11/15/2007 | P | PASS |
Tom Arcoraci
|
|
|
ken ###-####
|
BLD-Footing | 11/14/2007 | 11/14/2007 | 11/14/2007 | P | PASS |
Tom Arcoraci
|
|
|
Ken ###-####
|
Issue PAID IN FULL permit | | | 11/14/2007 | | DONE |
|
|
|
|
Telephone call | | | 11/8/2007 | | DONE |
|
|
|
t/c w ken at ###-#### - permit ready and fees given
|
Permit Ready to Issue | | | 11/8/2007 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 11/7/2007 | | DONE |
|
|
|
|
Plan assigned to (SRZ) | 10/10/2007 | 10/10/2007 | 11/6/2007 | | DONE |
|
|
|
Plan review Pending further re-submittals for Energy Compliance, and clarification on Two family dwelling seperation wall. (SRZ)
11/1/07 Need corrected Res-check to complete plan review. (SRZ) Recieved corrected res-check issued permit for SRZ he is out of town. (TLW)
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/6/2007 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 11/1/2007 | | 11/6/2007 | | PASS |
|
|
|
Passed permit for Sam He was out of town and I recieved reviesed res-check. (TLW)
|
Telephone call | | | 11/1/2007 | | DONE |
|
|
|
Left message with Applicant requesting new Res-check. (SRZ)
|
Plan resubmittals received | | | 11/1/2007 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 11/1/2007 | | |
|
|
|
|
Routing - PLAN CHECK | 10/11/2007 | | 11/1/2007 | | FAIL |
|
|
|
Need corrected Res-check to complete plan review. (SRZ)
|
1st review completed | | | 10/11/2007 | | FAIL |
|
|
|
|
Plan resubmittals requested | | | 10/11/2007 | | DONE |
|
|
|
Requested resubmittal from applicant. Detail and define One hour fire-resistance wall and/or floor-ceiling assemblies when tested in accordance with ASTM E 119 on plans per section R317.1 2003 IRC for Two family dwellings. Resubmit a new Energy compliance (RES-check) for Single family-Two family dwelling rather then Multi-family.(SRZ)
|
Case Summary (BLD) | | | 10/11/2007 | | |
|
|
|
|
Case Summary (BLD) | | | 10/11/2007 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 10/8/2007 | | 10/11/2007 | | PEND |
|
|
|
Plan review Pending further re-submittals for Energy Compliance, and clarification on Two family dwelling seperation wall. (SRZ)
|
Pending Assignment by SRZ | 10/4/2007 | | 10/10/2007 | | DONE |
|
|
|
10/10/2007 15:35:30 SRZ - activity updated through activity BLDA160 from case BLD07-02625.
|
Routing - PLANNING | 10/4/2007 | | 10/8/2007 | | PASS |
|
|
|
Routed to Cody Riddle-CUP05-10. Routed to Sue Hansen. O.K. as per Sarah
|
Routing - PUBLIC WORKS | 10/8/2007 | | 10/8/2007 | | PASS |
|
|
|
|
Routing - Addressing | 10/4/2007 | | 10/4/2007 | | PASS |
|
|
|
|
Application received | | | 10/4/2007 | | |
|
|
|
|