Permit Information
Permit NumberBLD07-03156
StatusFinaled
Name WELLMAN CONSTRUCTION
Site Address 8125 W FAIRVIEW AVE
Project NameSHOPKO PLAZA
Customer Number 
ePlanReviewNo
Description
(GANDOLFOS NEW YORK DELI - SHOPKO PLAZA) To build-out a 1,500 sq.ft. area of a 5,880 SHELL building to be used as a deli style restaurant per approved plans. Work includes construction of a 2-hour fire barrier wall between this 'A2' occupancy and other areas of building to create own fire area instead of sprinkler system. Interior walls to create a kitchen, two fully accessible restrooms, accessible route to all areas, service & dining area; install a type I hood with protected grease duct exhaust system, a type II hood; new electrical, mechanical and plumbing; suspended ceiling grid system, millwork and finishes. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice BLD4/23/20084/23/20086/6/2008 DONE
DetailsCathy Brown
First Notice has not been responded to.
First Notice 4/9/20084/23/2008 DONE
BLD-Final4/9/20084/9/20084/9/2008PPASS
DetailsMike Jordan
jim Phone #: ###-####. ok for perm occ.
Permanent Occupancy  4/9/2008 DONE
Temporary Occupancy UNPAID FEE  3/17/2008 DONE
BLD-Final3/14/20083/14/20083/14/2008PPART
DetailsJim Sly
Scheduled by a contractor via Hello! on 3/14/2008 at 5:54:04 AM. Contact: ###-####.
OK for Temp.......Waiting for Plumb, Electr, and CDHD to Perm.
FIRE-Final Inspection3/13/20083/14/20083/14/2008APASS
DetailsTroy Cobbley
life safety passed
FIRE-Final Inspection3/12/20083/13/20083/13/2008PFAIL
DetailsTroy Cobbley
Emergency lights and exit signs had not been mounted yet. Door hardware to the restrooms had not been mounted yet. The duct smoke detector needs the remote annunciator mounted and everything tested or the duct detector to be removed since it is not required per IMC.
BLD-Other3/11/20083/12/20083/12/2008APART
DetailsMike Jordan
Jim, ceiling grid; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt. pend elec ri above grid, also needs to wire diffusers andv finish installing clips on grid. Also inspected firecaulking at 2hr fire barrier wall for membrane and through penetrations. Will check remainder of grid on final.
BLD-Other2/20/20082/21/20082/21/2008APART
DetailsMike Jordan
james - first sheet on 2 hr fire wall Phone #: ###-####. ok to place 2nd layer.
BLD-Framing/Rough-in2/12/20082/13/20082/13/2008APASS
DetailsMike Jordan
jim Phone #: ###-####. Interior walls and hardlid only.
Issue PAID IN FULL permit  1/9/2008 DONE
Print Occupancy Form  1/8/2008 DONE
Telephone call  1/8/2008 DONE
t/c w jeff geibel at ###-#### - permit ready and fees given - also need ACHD receipt
Permit Ready to Issue  1/8/2008 DONE
PLANS/APPL TAKEN TO FRONT DESK  1/7/2008 DONE
Routing - PLAN CHECK1/2/2008 1/7/2008 PASS
DetailsDan Stuart
Resubmittals inserted into plans. Further clarifications & code requirements were red-lined on plan sheets and noted in attached plan review comments to be verified by structural field inspector.
Plan assigned to (DRS)12/20/2007 1/7/2008 PASS
DetailsDan Stuart
1/7/2008 15:06:37 DRS - activity updated through activity BLDA022 from case BLD07-03156.
Plan resubmittals received  1/4/2008  
received response letter and two copies of pages A2.1, A5.1, A7.1, A8.1, A8.3, A8.5.E2.0L, E3.0; taken to Dan Stuart
Routing - FIRE12/28/2007 1/2/2008 PASS
DetailsKenneth R Roule
1st review passed IFC 2003
1st review completed  1/2/2008 FAIL
Failed plan check
Routing - PLAN CHECK12/26/2007 12/28/2007 FAIL
DetailsDan Stuart
Resubmittals required. E-mailed plan review to architect. Routed to fire code analyst for review.
Plan resubmittals requested  12/28/2007 DONE
E-mail to Jeff Geibel.
Routing - PLUMBING12/21/2007 12/26/2007 PASS
DetailsBill VanDegrift
Routing - PUBLIC WORKS12/20/2007 12/21/2007 PASS
Routing PW Environmental12/21/2007 12/21/2007 PASS
1500 grease incpt put in w/ shell. plans show kitchen drains to GI. OK West Boise Sewer Dist jurisdiction
Routing PW Sewer Rating12/20/2007 12/20/2007 PASS
Pending Assignment by MYS12/13/2007 12/20/2007 DONE
12/20/2007 08:58:20 MYS - activity updated through activity BLDA168 from case BLD07-03156.
Plans ACCEPTED BY PLAN TECH  12/13/2007  
Recd Pcfee & Taken To Pln CK  12/13/2007 DONE
Application received  12/12/2007