Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD08-00344
StatusFinaled
Name RADIX CONSTRUCTION
Site Address 2337 S APPLE ST
Project NameCARRIAGE CROSSING
Customer Number 
ePlanReviewNo
Description
(NO TENANT - VANILLA FINISH - CARRIAGE CROSSING) To construct approximately 79 feet of interior tenant space separation wall to create a 4,414 sq. ft. 'VANILLA' finish space for future tenant, in new 10,120 sq. ft. shell constructed under BLD07-03193. Future tenant improvement plans are submitted and routing for review under BLD08-00345. No occupancy or use allowed under this permit. Work to include construction of interior walls to create two completed accessible restrooms; two fully compliant accessible drinking fountains, one low for forward approach and one high for standing approach ( Sec. 1109.5 IBC); a wall and service sink; suspended ceiling grid system; interior wall finishes, doors and hardware; and upgrade of electrical, mechanical & plumbing per adopted codes. All per reviewed plans to include red-line notes on plans and all attached plan review comments / conditions of all reviewing agencies. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice BLD8/11/20088/11/20089/4/2008 DONE
DetailsCathy Brown
First Notice has not been responded to.
First Notice6/30/20086/30/20088/11/2008 DONE
DetailsJim Storey
BLD-Final6/30/20086/30/20086/30/2008PPASS
DetailsJim Storey
Kevin Phone #: ###-####
DOC - Permit Finaled6/30/20086/30/20086/30/2008PPASS
DetailsJim Storey
BLD-Final6/6/20086/6/20086/10/2008PCANC
DetailsJim Storey
Kil Phone #: ###-####
FIRE-Final Inspection6/6/20086/6/20086/6/2008PPASS
DetailsForrest France
Kil- fire life saftey Phone #: ###-####
BLD-Framing/Rough-in6/2/20086/2/20086/2/2008PPART
DetailsJim Storey
keil - ceiling grid Phone #: ###-#### ceilling ok pending ele c/n.
BLD-Framing/Rough-in5/30/20085/30/20085/30/2008PPART
DetailsJim Storey
keil -grid ceiling Phone #: ###-####pending ele
BLD-Framing/Rough-in5/22/20085/22/20085/22/2008PPASS
DetailsJim Storey
kyle Note: cover for restrooms Phone #: ###-####
BLD-Energy code compliance5/20/20085/20/20085/20/2008PPART
DetailsMike Jordan
keal Phone #: ###-####. Items for restrooms not yet completed. Tenant wall ok.
BLD-Framing/Rough-in5/16/20085/16/20085/16/2008PPART
DetailsJim Storey
keil Phone #: ###-#### tennet wall non-rated ok/ water closet wrong c/l to wall to meet a117/ need backing for grab bars/ need others aproval/ ceilling framing needs top flange screwed to ledger track in bathrooms.
Issue PAID IN FULL permit  4/29/2008 DONE
Telephone call  4/24/2008 DONE
talked to matt rhees at ###-#### that permit is ready
Permit Ready to Issue  4/24/2008  
Inspection Record Card- Bld  4/15/2008 DONE
1st review completed  4/11/2008 PASS
Routing - PLAN CHECK4/11/2008 4/11/2008 PASS
DetailsDan Stuart
To permit desk to issue.
PLANS/APPL TAKEN TO FRONT DESK  4/11/2008 PASS
Plan assigned to (DRS)3/4/2008 4/11/2008 PASS
DetailsDan Stuart
4/11/2008 15:18:58 DRS - activity updated through activity BLDA022 from case BLD08-00344.
Routing - FIRE4/9/2008 4/11/2008 PASS
DetailsScott Arellano
Attached IFC comments to plans
Plan Reviewer's activity  4/10/2008 DONE
Copy of plan review clarifications faxed to Matt Rhees, architect.
Routing - PLAN CHECK3/5/2008 4/9/2008 PEND
DetailsDan Stuart
No resubmittals required. Routing plans to fire code analyst for review.
Routing - PUBLIC WORKS3/4/2008 3/5/2008 PASS
DetailsBeverly Hall
Routing PW Sewer Rating3/4/2008 3/4/2008 PASS
DetailsLouise Waldorf
Pending Assignment by MYS2/26/2008 3/4/2008 DONE
DetailsMarlene Southard
3/4/2008 15:08:43 MYS - activity updated through activity BLDA168 from case BLD08-00344.
Plans ACCEPTED BY PLAN TECH  2/27/2008  
Application received  2/26/2008  
Recd Pcfee & Taken To Pln CK  2/26/2008