Third Notice BLD | 12/22/2008 | 12/22/2008 | 12/23/2008 | | DONE |
Cathy Brown
|
|
|
Second Notice has not been responded to.
|
Second Notice BLD | 11/7/2008 | 11/7/2008 | 12/22/2008 | | DONE |
Cathy Brown
|
|
|
First Notice has not been responded to.
|
First Notice | | 9/25/2008 | 11/7/2008 | | DONE |
|
|
|
|
Permanent Occupancy UNPAID FEE | | | 9/25/2008 | | DONE |
Tisha Gallop
|
|
|
|
BLD-Final | 9/24/2008 | 9/24/2008 | 9/24/2008 | P | PASS |
Mike Jordan
|
|
|
Curt- call 30 mins prior to going Phone #: ###-####. All issues resolved. ok for perm occ.
|
BLD-Final | 9/18/2008 | 9/19/2008 | 9/19/2008 | A | NR |
Mike Jordan
|
|
|
Curt- late am Phone #: ###-####. Needs plumbing final.
|
FIRE-Final Inspection | 9/18/2008 | 9/19/2008 | 9/19/2008 | A | PASS |
Troy Cobbley
|
|
|
fire life safety passed
|
BLD-Final | 9/17/2008 | 9/18/2008 | 9/18/2008 | P | NR |
Mike Jordan
|
|
|
Curt Phone #: ###-####. Needs plumbing final and life/safety.
|
FIRE-Final Inspection | 9/17/2008 | 9/18/2008 | 9/18/2008 | A | FAIL |
Troy Cobbley
|
|
|
Provide exit signs/emergency lights as discussed and marked on the city approved plans and provide approved door hardware as discussed and shown on the approved plans.
|
BLD-Framing/Rough-in | 9/11/2008 | 9/12/2008 | 9/12/2008 | A | PART |
Mike Jordan
|
|
|
shane - ceiling grid Phone #: ###-####. Ceiling grid ok. Needs elec. and mech ri insp. prior to cover. Also needs to leave portion of grid out were draftstop and corridor wall still need to be repaired.
|
BLD-Framing/Rough-in | 8/27/2008 | 8/28/2008 | 8/28/2008 | P | PART |
Jim Sly
|
|
|
kurt Phone #: ###-#### - please call 1/2 hr prior to inspection Framing appears OK.......Ok to cover areas not affected by CN.... Fix holes in R-19 ceiling insul, fix draftstop, fix all penitrations in wall adjacent to 1hr corridor, Architect to address new 20 min rated door to be installed in 1hr corridor and how it can meet ADA req. at sides of door.
|
Issue PAID IN FULL permit | | | 8/7/2008 | | DONE |
|
|
|
|
Print Occupancy Form | | | 7/21/2008 | | DONE |
|
|
|
|
Telephone call | | | 7/21/2008 | | DONE |
|
|
|
left vm for kelly patrick at ###-#### - permit ready and fees given - also need gc name and rce#
|
Permit Ready to Issue | | | 7/21/2008 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 7/9/2008 | | 7/18/2008 | | PASS |
Dan Stuart
|
|
|
Resubmittals provided were incomplete. Plans were red-lined to reflect code requirements and the plan review attached to plans was modified to indicate required code compliance to be verified by field inspectors. Copy of final report e-mailed to John Reseigh to respond to field inspectors and contractors request for any required details to show code compliance. Taking to permit desk to issue.
|
Plan resubmittals received | | | 7/18/2008 | | |
Dan Stuart
|
|
|
Recieved one letter to Dan S from John Reseigh dated 7/16/08 two copies of sheets a2.1 a3.1 a10.1 and taken to dan stuarts desk 7/18/08 @ 10:45 ALR
|
Plan Reviewer's activity | | | 7/18/2008 | | DONE |
|
|
|
Plans red-lined and note provided for required corrections for code compliance. Copy to architect.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/18/2008 | | PASS |
|
|
|
As noted and attached to plans.
|
Plan assigned to (DRS) | 6/23/2008 | | 7/18/2008 | | PASS |
Dan Stuart
|
|
|
7/18/2008 14:15:00 DRS - activity updated through activity BLDA022 from case BLD08-01351.
|
Routing - FIRE | 7/7/2008 | 7/7/2008 | 7/9/2008 | | PASS |
Scott Arellano
|
|
|
Attached IFC comments to plans
|
1st review completed | | | 7/9/2008 | | FAIL |
|
|
|
Failed Plan Check
|
Route to Impact Fee Review | 7/7/2008 | 7/10/2008 | 7/7/2008 | | PASS |
Cindy M. Gould
|
|
|
Tenant improvements no fees
|
Plan resubmittals requested | | | 7/7/2008 | | DONE |
|
|
|
E-mailed plan review to architect.
|
Routing - PLAN CHECK | 6/24/2008 | | 7/7/2008 | | FAIL |
Dan Stuart
|
|
|
Resubmittals required. Copy of plan review e-mailed to Pat McKeegan. routing to fire dept.
|
Routing - PUBLIC WORKS | 6/23/2008 | | 6/24/2008 | | PASS |
Beverly Hall
|
|
|
|
Routing PW Sewer Rating | 6/24/2008 | | 6/24/2008 | | PASS |
Louise Waldorf
|
|
|
|
Pending Assignment by MYS | 6/19/2008 | | 6/23/2008 | | DONE |
Marlene Southard
|
|
|
6/23/2008 14:45:41 MYS - activity updated through activity BLDA168 from case BLD08-01351.
|
Plans ACCEPTED BY PLAN TECH | | | 6/19/2008 | | DONE |
Tisha Gallop
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 6/19/2008 | | DONE |
Tisha Gallop
|
|
|
|
Application received | | 6/18/2008 | 6/18/2008 | | DONE |
Tisha Gallop
|
|
|
|