Third Notice BLD | 1/29/2009 | 1/29/2009 | 3/3/2009 | | DONE |
Patricia Smith
|
|
|
Second Notice has not been responded to.
|
Second Notice BLD | 1/16/2009 | 1/16/2009 | 1/29/2009 | | DONE |
Cathy Brown
|
|
|
First Notice has not been responded to.
|
First Notice | 12/29/2008 | 12/29/2008 | 1/16/2009 | | DONE |
Jim Storey
|
|
|
|
BLD-Final | 12/29/2008 | 12/29/2008 | 12/29/2008 | P | PASS |
Jim Storey
|
|
|
l/c isued
|
DOC - Permit Finaled | 12/29/2008 | 12/29/2008 | 12/29/2008 | P | PASS |
Jim Storey
|
|
|
l/c isued
|
BLD-Final | 11/28/2008 | 12/1/2008 | 12/1/2008 | A | FAIL |
Jim Storey
|
|
|
terry/ on site ken hawk Phone #: ###-#### need to fire stop flex at fire wall east/south area.
|
BLD-Final | 11/26/2008 | 11/28/2008 | 11/28/2008 | A | NH |
Jim Storey
|
|
|
terry/ on site ken hawk Phone #: ###-#### no access rolled to monday am.
|
BLD-Other | 9/29/2008 | 9/30/2008 | 9/30/2008 | P | PASS |
Jim Storey
|
|
|
Kyle- rebar Phone #: ###-#### and fire wall ok on membrane protection ok to rock stud framing.
|
BLD-Framing/Rough-in | 9/29/2008 | 9/29/2008 | 9/29/2008 | P | PART |
Jim Storey
|
|
|
Kyle Phone #: ###-####
|
BLD-Footing | 9/22/2008 | 9/23/2008 | 9/23/2008 | A | PASS |
Jim Storey
|
|
|
kyle - rebar - hanger 3 Phone #: ###-####
|
Plan Reviewer's activity | | | 9/22/2008 | | DONE |
|
|
|
Contractor came in to discuss one hour wall construction on both sides of paint booths as per fire code. Reviewed with Scott Arellano & Sam Rogers. Existing walls are finished on one side with wood cover on hanger side. Okay to drywall over wood with 5/8" type 'X' drywall then furr-out with metal studs and add another layer of 5/8" type 'X' with all joints tape and finished per contractor request.
|
Plan Reviewer's activity | | | 9/22/2008 | | DONE |
|
|
|
Sent e-mail to Jim Storey on acceptance of alternate 1-hour wall construction proposed and accepted.
|
Issue PAID IN FULL permit | | | 9/17/2008 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 9/5/2008 | | DONE |
Alexandra L. DeYoung
|
|
|
|
Telephone call | | | 9/5/2008 | | DONE |
Alexandra L. DeYoung
|
|
|
LM for Jeff Likes at ###-####, permit ready fees given
|
Permit Ready to Issue | | | 9/5/2008 | | DONE |
Alexandra L. DeYoung
|
|
|
|
Plan assigned to (DRS) | 8/14/2008 | | 9/4/2008 | | PASS |
Dan Stuart
|
|
|
9/4/2008 17:21:14 DRS - activity updated through activity BLDA022 from case BLD08-01750.
|
Routing - PLAN CHECK | 8/20/2008 | | 9/4/2008 | | PASS |
Dan Stuart
|
|
|
Attached project description and electrical, mechanical and fire code reference for field inspection and approval of specific requirements for spray paint booths and new electrical / mechanical.
|
Telephone call | | | 9/4/2008 | | DONE |
|
|
|
Called Terry Kelly of Baker Construction requesting site plan for the Western Aircraft complex (5 or more buildings) with dimensions and distances between buildings.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/4/2008 | | PASS |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 9/4/2008 | | |
|
|
|
|
Case Summary (BLD) | | | 9/4/2008 | | |
|
|
|
|
Routing - FIRE | 8/19/2008 | | 8/20/2008 | | PASS |
Scott Arellano
|
|
|
Attached IFC comments to plans. A seperate fire sprinkler permit will be requried for the installation of the paint booth and mixing room fire extinguishing system.
|
1st review completed | | | 8/20/2008 | | PASS |
|
|
|
|
Routing - Erosion and Sediment | | | 8/19/2008 | | CANC |
Steven Webb
|
|
|
No ESC is needed for the T.I. of this project.CAS
|
Routing - PUBLIC WORKS | 8/14/2008 | | 8/19/2008 | | PASS |
Beverly Hall
|
|
|
|
Routing PW Sewer Rating | 8/15/2008 | | 8/15/2008 | | PASS |
Louise Waldorf
|
|
|
|
Routing PW Environmental | 8/15/2008 | | 8/15/2008 | | PASS |
Walt Baumgartner
|
|
|
OK, no PreT concerns w/ paint booths.
|
Application received | | 8/12/2008 | 8/14/2008 | | DONE |
Barbara Stitt
|
|
|
|
Pending Assignment by MYS | 8/12/2008 | | 8/14/2008 | | BLDA |
Marlene Southard
|
|
|
8/14/2008 14:08:54 MYS - activity updated through activity BLDA168 from case BLD08-01750.
|
Recd Pcfee & Taken To Pln CK | | | 8/14/2008 | | DONE |
Barbara Stitt
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 8/14/2008 | | DONE |
Barbara Stitt
|
|
|
|