Information based on query as of Sunday, September 13, 2026.
Permit Information
Permit NumberBLD08-02172
StatusFinaled
Name CROWN CONSTRUCTION LLC
Site Address 8488 W OVERLAND RD
Project NameEINSTEIN'S OILERY
Customer Number 
ePlanReviewNo
Description
(EINSTEIN'S OILERY) Interior and exterior remodel to an existing building, 1,664 sq. ft. main level with a 1,472 sq. ft. basement/lube pit, for use as a service repair garage oil changing lube business. Planning approvals under CUP08-00089 and DRH08-00285. Original building, BLD97-01615, was for Quick Lube. Work will include removal of concrete/steel deck infill of floor done for previous sign tenant; install new lube catwalks & storage for new and used oil; exterior light fixture's; to relocate or add walls to create a fully accessible restroom, private office and compressor room; new exterior framing, facade and roof overbuild at the existing main entry / waiting room area; work on electrical, mechanical and plumbing systems. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice 6/5/20098/5/2009 DONE
sent by mail
Permanent Occupancy  6/5/2009 DONE
DetailsAlexandra L. DeYoung
BLD-Final6/4/20096/4/20096/4/2009PPASS
DetailsMike Jordan
Please call prior to inspection--Kelly Phone #: ###-####. OK for perm occ.
Zoning Approval6/4/20096/4/20096/4/2009 DONE
DetailsAndrea Tuning
The contructed building now matches the approved plans. Permanent occupancy can be issued.
BLD-Final3/16/20093/17/20093/17/2009APART
DetailsMike Jordan
Kelly Phone #: ###-####. ok for temp occ. No mech alterations were done.
Temporary Occupancy3/17/20096/15/20093/17/2009 DONE
DetailsBarbara Stitt
Zoning Approval3/16/20093/16/20093/16/2009 PASS
DetailsAndrea Tuning
The building is not complete and does not match the approved plans. The building is painted the incorrect color, does not have soffits or a roof, has unfinished vents on the exterior of the building, has added light fixtures, has a damaged trash enclosure, does not contain the upper horizontal band on the building, is not landscaped, has loose debris in the drive aisle, and the loading zone for the accessible space has not been striped. The applicant will be required to post a bond in the amount that it would cost to modify the site and the building to match the approved plans or obtain a DR modification to allow the building to remain as constructed. The applicant has submitted a bond for the changes to the building. ANT 3-16-09
BLD-Final3/12/20093/13/20093/13/2009PNR
DetailsMike Jordan
Kelly - for temp Phone #: ###-####. Needs zoning.
FIRE-Final Inspection3/12/20093/13/20093/13/2009APASS
DetailsTroy Cobbley
Life safety passed. The contractor stated that the building address would be installed on both sides of the marquee at the street and the thumbturn dead bolt would be removed from the northwest exit door.
BLD-Framing/Rough-in2/26/20092/27/20092/27/2009APART
DetailsMike Jordan
framing insp. on the exterior facade//Kelley Miller ###-####. Framing for new storefront. ok to cover. Still needs to build cricket for storefront support.
BLD-Framing/Rough-in1/27/20091/28/20091/28/2009APASS
DetailsMike Jordan
Framing/Rough-in inspection for interior work. Phone #: ###-#### Internet Inspection Request from: Kelly Miller. Interior wood framed walls for office,restroom and compressor room.
BLD-Framing/Rough-in1/13/20091/14/20091/14/2009PCANC
DetailsMike Jordan
kelly Phone #: ###-####
Issue PAID IN FULL permit  1/12/2009 DONE
Print Occupancy Form  1/8/2009 DONE
Details
Telephone call  1/8/2009 DONE
Details
left vm for kelly miller at ###-#### - permit ready and fees given
Permit Ready to Issue  1/8/2009 DONE
Details
Routing - PLAN CHECK12/22/2008 1/7/2009 PASS
DetailsDan Stuart
Resubmittals of 1/6/09 inserted into original plans. Plan review modified and clarifications added for deferred submittal truss details. Plans red-lined. Plans to permit desk to issue.
Plan resubmittals received  1/7/2009  
DetailsDan Stuart
Received 3 copies of plan review comments response letter, 2 copies of structural calcs, 3 copies of sheets 3, 4, 5 and taken to Dan Stuart's desk///1-7-09 BAS
PLANS/APPL TAKEN TO FRONT DESK  1/7/2009 PASS
Plan assigned to (DRS)10/13/2008 1/7/2009 PASS
DetailsDan Stuart
1/7/2009 16:06:55 DRS - activity updated through activity BLDA022 from case BLD08-02172.
Routing - FIRE12/19/2008 12/22/2008 PASS
DetailsScott Arellano
Attached IFC comments to plans
Routing - PLAN CHECK11/18/2008 12/19/2008 FAIL
DetailsDan Stuart
Resubmittals incomplete or in conflict between engineering and architect drawings. E-mail to architect for corrections. Routing to fire code analyst.
Plan resubmittals received  12/19/2008  
DetailsDan Stuart
Rec'd three copies of trasmittal letter and info packet, and three copies of sheets 3, 4 and 5; taken to Dan S
Additional plans submitted  12/9/2008 DONE
DetailsScott Arellano
Additional tank layout provided by building owner. Combustible liquids determined to be Class III-B. Quantities will be below maximum allowable per IFC chapter 27.
Case Summary (BLD)  12/3/2008 DONE
Meeting  12/1/2008 DONE
Met with Kelly Miller, Crown Const. to review plan review and data prepared by Mr. Mike Fairchild and Merlin Phillips. Reviewed question on truss design / fabrication. Kelly will have truss engineer indicate full and partial truss. New structural engineer to review existing roof capability for overbuild and snow drifting at new raised wall sections and also provide engineering design criteria as part of plan cover sheet or separate structural plan sheet. Kelly will have his electrician contact Jim Schmer to discuss lighting fixtures for this occupancy use. Original exhaust ducting is still in place. Will have design professional review capability of existing to meet current mechanical & electrical code exhaust requirements. Kelly to review occupancy use with Mike Fairchild. Occupancy use (H or S1 not an F1) with accessory 'B' waiting room. The south side stairway is having the wall enclosure constructed as part of the sign shop permit removed and there will be no enclosed storage space under this stair. All storage tanks in this area will be in full view of all in basement and does not require protection as long as storage is not enclosed. The north side stair is enclosed within a concrete wall, part of original plans, and does not have access beneath for storage. Number of tanks, capacity of each (including existing larger tank), classification of combustible/flammable liguids (i.e. C-IIIB) allowed quantitity per Tble 307 IBC vs. actual quantity determines if "H" or "S1" occupancy.
Routing - FIRE11/14/200811/14/200811/18/2008 FAIL
DetailsScott Arellano
Faxed and emailed resubmittal items to architect.
1st review completed  11/18/2008 FAIL
Failed Plan Check, Fire
Route to Impact Fee Review11/14/200811/19/200811/17/2008 PASS
DetailsCindy M. Gould
Tenant improvement, no new square footage.
Plan resubmittals requested  11/14/2008 DONE
Plan review to Mike Fairchild.
Routing - PLAN CHECK10/22/2008 11/14/2008 FAIL
DetailsDan Stuart
Copy of plan review required resubmittals e-mailed and faxed to architect, Mike Fairchild. Routing plans to fire code analyst for review.
Routing - PLANNING10/22/2008 10/22/2008 PASS
DetailsAndrea Tuning
Routing - PLAN CHECK10/16/2008 10/22/2008 PEND
DetailsDan Stuart
New plan sheets #2, landscaping plan, inserted into plans. Re-routing plans back to Planning, Andrea Tuning, for re-review.
Plan resubmittals received  10/21/2008 DONE
RECEIVED 2 COPIES OF SHEET 2 OF 5 taken to Dan S.
Routing - PLANNING10/15/2008 10/16/2008 PASS
DetailsSusan Riggs
Approved per CUP08-00089 - Susan Riggs 10-16-08.
Routing - Design Review10/16/2008 10/16/2008 FAIL
DetailsAndrea Tuning
Denied per DRH08-00285. The applicant will be required to submit a site plan and landscape plan showing a landscape planter around the building as was approved with DRH08-00285. The applicant should also identify what landscaping is proposed within the planter. ANT 10-16-08
Routing - Erosion and Sediment10/15/2008 10/15/2008 PASS
DetailsSteven Webb
ESC plan waiver approved with attached conditions. ESC08-00876
Routing - PUBLIC WORKS10/13/2008 10/15/2008 PASS
DetailsBeverly Hall
Routing PW Environmental10/14/2008 10/14/2008 PASS
DetailsTerry Alber
Routing PW Sewer Rating10/14/2008 10/14/2008 PASS
DetailsLouise Waldorf
Telephone call  10/13/2008 DONE
DetailsJason Blais
Discussed on phone and sent e-mail to Mike Fairchild. An Erosion & Sediment Control application and Waiver letter are required to be submitted because of the exterior work shown on the project. Also needs to resubmit structural calculations that have the engineer's stamp and signature. Explained the documents are needed prior to continuing the process of assigning and routing plans for review.
Additional plans submitted  10/13/2008 DONE
DetailsJason Blais
Received ESC Application and Waiver Letter. Received new structural engineer calculations stamped and signed.
Pending Assignment by JCB10/9/2008 10/13/2008 DONE
DetailsJason Blais
Plans ACCEPTED BY PLAN TECH  10/10/2008 DONE
DetailsDarla L Downs
Recd Pcfee & Taken To Pln CK  10/10/2008 DONE
DetailsDarla L Downs
Application received 10/9/2008