BLD-Final | 5/4/2009 | 5/5/2009 | 5/5/2009 | A | PASS |
Dave Hannah
|
|
|
jeff Phone #: ###-####
|
DOC - Permit Finaled | 5/5/2009 | 5/5/2009 | 5/5/2009 | P | PASS |
Dave Hannah
|
|
|
|
BLD-Grading Inspection | 5/5/2009 | 5/5/2009 | 5/5/2009 | P | DONE |
Terry Records
|
|
|
Final grading and drainage approved
|
BLD-Energy code compliance | 2/10/2009 | 2/10/2009 | 2/10/2009 | P | PART |
Dave Hannah
|
|
|
ok to cover after fire sprinkler is oked
|
BLD-Framing/Rough-in | 2/5/2009 | 2/5/2009 | 2/5/2009 | P | PART |
Jim Sly
|
|
|
jeff Phone #: ###-#### Interior framing only........ Verbal C/N. to Jeff and Framer.......Check DG1 3ply girder above stairway....... Eng. Shows Mid bearing point with 23,000 lb reaction? Verify with truss engineer. If valid, transfer point load to footing.....Provide Engineering for new footing. (no footing poured). OK to insulate.
|
Routing Walk-In (BLD) | 1/2/2009 | 1/2/2009 | 1/6/2009 | P | FAIL |
Perry Paine
|
|
|
contractor wants to place inground pool that has been marked on plans but not part of this permit at theis time. Speaking with planning, a swimming pool is not allowed on the open side of a lot. Public works has questions on the pool filter discharge requirements as a shallow injectio well is not an option at this hillside site. I told contractor that the bes method would be to connect the pool to the sanitary sewer if it is approved for placement. 1/6/2009 pep
|
Routing Walk-In (PW Hillside) | 1/2/2009 | 1/2/2009 | 1/2/2009 | P | DONE |
Darla L Downs
|
|
|
1/2/2009 12:47:01 DLD - activity updated through activity BLDI252 from case BLD08-02377.
|
BLD-Foundation | 12/3/2008 | 12/3/2008 | 12/3/2008 | P | PASS |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 12/3/2008 at 10:10:31 AM. Contact: ###-####.
|
BLD-Footing | 12/1/2008 | 12/1/2008 | 12/1/2008 | A | PASS |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 12/1/2008 at 6:59:05 AM. Contact: ###-####.
|
BLD-Footing | 11/26/2008 | 11/26/2008 | 11/26/2008 | P | CANC |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 11/26/2008 at 8:25:12 AM. Contact: ###-####.
|
PubWorks Subgrade Approval | 11/26/2008 | 11/26/2008 | 11/26/2008 | | DONE |
Terry Records
|
|
|
Footing subgrade approved by the geotechnical engineer
|
Issue PAID IN FULL permit | | | 11/24/2008 | | DONE |
|
|
|
|
Plan assigned to (PEP) | 11/20/2008 | 11/20/2008 | 11/21/2008 | | PASS |
Perry Paine
|
|
|
11/21/2008 13:37:08 PEP - activity updated through activity BLDA022 from case BLD08-02377.
|
Route to Impact Fee Review | 11/6/2008 | 11/12/2008 | 11/21/2008 | | PASS |
Cindy M. Gould
|
|
|
|
Routing - PLAN CHECK | 11/18/2008 | | 11/21/2008 | | PASS |
Perry Paine
|
|
|
|
Routing - PLAN CHECK | 11/21/2008 | | 11/21/2008 | | PASS |
Perry Paine
|
|
|
|
Case Summary (BLD) | | | 11/21/2008 | | |
|
|
|
|
Inspection Record Card- Bld | | | 11/21/2008 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/21/2008 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 11/21/2008 | | DONE |
|
|
|
|
Telephone call | | | 11/21/2008 | | DONE |
Cathy Brown
|
|
|
lft vm with jeff fullmer ###-#### that permit and fees are ready to be picked up
|
Permit Ready to Issue | | | 11/21/2008 | | DONE |
Cathy Brown
|
|
|
|
Routing - FIRE | 11/13/2008 | | 11/20/2008 | | PASS |
Sam Rogers
|
|
|
Sam Rogers. Need to consult with fire marshal to evaluate need for sprinklers, due to lack of information for this subdivision. Plans need to be rerouted to Fire prior to issuing permit; forwarding at this time to building plan reviewer to expedite the review process. ****13D FIRE SPRINKLER SYSTEM required.*** per subsequesnt discussion with Mark Senteno, due to grade of FD access road into subdivision.
|
Case Summary (BLD) | | | 11/20/2008 | | |
|
|
|
|
Routing - FIRE | | | 11/20/2008 | | PASS |
|
|
|
Based on discussion with contractor Jeff Fulton, they intend to provide fire sprinklers in this house. The system shall be designed in accordance with NFPA 13D. A separate Fire Sprinkler permit shall be obtained prior to beginning sprinkler installation work. Also it is recommended to contact United Water, John Lee, regarding water tap requirements for the sprinkler system.
|
Routing - Erosion and Sediment | 11/12/2008 | | 11/13/2008 | | PASS |
Steven Webb
|
|
|
Reference ESC08-00866.
|
Routing - PLANNING | 11/7/2008 | | 11/12/2008 | | PASS |
Sue Cummings
|
|
|
See redlines on basement floor plan and electrical. Only one kitchen allowed. Pool in front yard is not part of this permit. CFH08-00032 Sue Cummings
|
Routing - PUBLIC WORKS | 10/7/2008 | | 11/7/2008 | | PASS |
Louise Waldorf
|
|
|
|
Routing - PUBLIC WORKS GRADING | 11/6/2008 | | 11/7/2008 | | PASS |
Terry Records
|
|
|
Approved as Category 1 by CFH08-00032
|
Routing - Addressing | 11/6/2008 | | 11/6/2008 | | PASS |
Chris Pichardo
|
|
|
|
Application received | | 11/6/2008 | | | |
|
|
|
|