Permit Information
Permit NumberBLD08-02377
StatusFinaled
Name CONCAR INC
Site Address 2480 S STARLITE LN
Project Name 
Customer Number 
ePlanReviewNo
Description
This project is for the construction of a new 2-story single family dwelling. An NFPA 13D fire sprinkler system is required by the Fire Department. The lower level will have 1,280s.f. of living area along with a three car garage of 875s.f. The upper and main level will have 2,853 s.f. along with 693s.f. of above grade balcony area that includes an 84s.f. covered entry area. The exterior balcony and stairways are using cable guardrails and must meet the requirements of the Building Division Policy of March 20, 2008 (attached). R-1C ok per Sue Cummings per notes restricting lower level cannot have a kitchen, under counter refer only and there is not to be a 220 receptacle for a range. Separate electrical, plumbing and mechanical permits are required. ESC08-00866 permit is already in force for the grading permit MIS08-00157. ESC plans were approved through these permits also. The grading and drainage must be certified by an approval letter from the design engineer of record to Public Works prior to issuance of a building dept final approval. All per the approved plans as marked engineering calculations and the engineer's details; Energy code component method along with the plan review notes. pep
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/4/20095/5/20095/5/2009APASS
DetailsDave Hannah
jeff Phone #: ###-####
DOC - Permit Finaled5/5/20095/5/20095/5/2009PPASS
DetailsDave Hannah
BLD-Grading Inspection5/5/20095/5/20095/5/2009PDONE
DetailsTerry Records
Final grading and drainage approved
BLD-Energy code compliance2/10/20092/10/20092/10/2009PPART
DetailsDave Hannah
ok to cover after fire sprinkler is oked
BLD-Framing/Rough-in2/5/20092/5/20092/5/2009PPART
DetailsJim Sly
jeff Phone #: ###-####
Interior framing only........ Verbal C/N. to Jeff and Framer.......Check DG1 3ply girder above stairway....... Eng. Shows Mid bearing point with 23,000 lb reaction? Verify with truss engineer. If valid, transfer point load to footing.....Provide Engineering for new footing. (no footing poured). OK to insulate.
Routing Walk-In (BLD)1/2/20091/2/20091/6/2009PFAIL
DetailsPerry Paine
contractor wants to place inground pool that has been marked on plans but not part of this permit at theis time. Speaking with planning, a swimming pool is not allowed on the open side of a lot. Public works has questions on the pool filter discharge requirements as a shallow injectio well is not an option at this hillside site. I told contractor that the bes method would be to connect the pool to the sanitary sewer if it is approved for placement. 1/6/2009 pep
Routing Walk-In (PW Hillside)1/2/20091/2/20091/2/2009PDONE
DetailsDarla L Downs
1/2/2009 12:47:01 DLD - activity updated through activity BLDI252 from case BLD08-02377.
BLD-Foundation12/3/200812/3/200812/3/2008PPASS
DetailsDave Hannah
Scheduled by a contractor via Hello! on 12/3/2008 at 10:10:31 AM. Contact: ###-####.
BLD-Footing12/1/200812/1/200812/1/2008APASS
DetailsDave Hannah
Scheduled by a contractor via Hello! on 12/1/2008 at 6:59:05 AM. Contact: ###-####.
BLD-Footing11/26/200811/26/200811/26/2008PCANC
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 11/26/2008 at 8:25:12 AM. Contact: ###-####.
PubWorks Subgrade Approval11/26/200811/26/200811/26/2008 DONE
DetailsTerry Records
Footing subgrade approved by the geotechnical engineer
Issue PAID IN FULL permit  11/24/2008 DONE
Plan assigned to (PEP)11/20/200811/20/200811/21/2008 PASS
DetailsPerry Paine
11/21/2008 13:37:08 PEP - activity updated through activity BLDA022 from case BLD08-02377.
Route to Impact Fee Review11/6/200811/12/200811/21/2008 PASS
DetailsCindy M. Gould
Routing - PLAN CHECK11/18/2008 11/21/2008 PASS
DetailsPerry Paine
Routing - PLAN CHECK11/21/2008 11/21/2008 PASS
DetailsPerry Paine
Case Summary (BLD)  11/21/2008  
Inspection Record Card- Bld  11/21/2008  
PLANS/APPL TAKEN TO FRONT DESK  11/21/2008 DONE
Inspection Record Card- Bld  11/21/2008 DONE
Telephone call  11/21/2008 DONE
DetailsCathy Brown
lft vm with jeff fullmer ###-#### that permit and fees are ready to be picked up
Permit Ready to Issue  11/21/2008 DONE
DetailsCathy Brown
Routing - FIRE11/13/2008 11/20/2008 PASS
DetailsSam Rogers
Sam Rogers. Need to consult with fire marshal to evaluate need for sprinklers, due to lack of information for this subdivision. Plans need to be rerouted to Fire prior to issuing permit; forwarding at this time to building plan reviewer to expedite the review process. ****13D FIRE SPRINKLER SYSTEM required.*** per subsequesnt discussion with Mark Senteno, due to grade of FD access road into subdivision.
Case Summary (BLD)  11/20/2008  
Routing - FIRE  11/20/2008 PASS
Based on discussion with contractor Jeff Fulton, they intend to provide fire sprinklers in this house. The system shall be designed in accordance with NFPA 13D. A separate Fire Sprinkler permit shall be obtained prior to beginning sprinkler installation work. Also it is recommended to contact United Water, John Lee, regarding water tap requirements for the sprinkler system.
Routing - Erosion and Sediment11/12/2008 11/13/2008 PASS
DetailsSteven Webb
Reference ESC08-00866.
Routing - PLANNING11/7/2008 11/12/2008 PASS
DetailsSue Cummings
See redlines on basement floor plan and electrical. Only one kitchen allowed. Pool in front yard is not part of this permit. CFH08-00032 Sue Cummings
Routing - PUBLIC WORKS10/7/2008 11/7/2008 PASS
DetailsLouise Waldorf
Routing - PUBLIC WORKS GRADING11/6/2008 11/7/2008 PASS
DetailsTerry Records
Approved as Category 1 by CFH08-00032
Routing - Addressing11/6/2008 11/6/2008 PASS
DetailsChris Pichardo
Application received 11/6/2008