Second Notice | | 7/22/2009 | 8/6/2009 | | DONE |
|
|
|
This permit finaled on the web by Ken Litzinger
|
First Notice | | 4/9/2009 | 7/22/2009 | | DONE |
|
|
|
|
BLD-Final | 4/9/2009 | 4/9/2009 | 4/9/2009 | A | PASS |
Jim Storey
|
|
|
Please call 1/2 hour before inspection....thanks Phone #: ###-#### Internet Inspection Request from: Ken Litzinger final ok card on site.
|
Permanent Occupancy UNPAID FEE | | | 4/9/2009 | | DONE |
Tisha Gallop
|
|
|
|
Plan assigned to (TLW) | 3/31/2009 | | 4/7/2009 | | PASS |
Tim L. Woodard
|
|
|
|
BLD-Final | 4/3/2009 | 4/3/2009 | 4/3/2009 | P | NR |
Jim Storey
|
|
|
Please call 1/2 hour before inspectioin..thanks Phone #: ###-#### Internet Inspection Request from: Ken Litzinger
|
BLD-Final | 4/3/2009 | 4/3/2009 | 4/3/2009 | A | DEFR |
Jim Storey
|
|
|
Please call 1/2 hour before inspectioin..thanks Phone #: ###-#### Internet Inspection Request from: Ken Litzinger to pm
|
Routing - MECHANICAL | 3/31/2009 | | 4/1/2009 | | PASS |
Troy James
|
|
|
|
Routing - PLAN CHECK | 4/1/2009 | | 4/1/2009 | | PASS |
Tim L. Woodard
|
|
|
Mechanical has approved ventilation drawings. TLW
|
(F) Reprint permit | | | 4/1/2009 | | DONE |
Tisha Gallop
|
|
|
|
CHANGE STATUS TO (RDY) | | | 4/1/2009 | | DONE |
Tisha Gallop
|
|
|
revised approved mechanical plans ready for pick up, no fees
|
CHANGE STATUS TO (ISS) | | | 4/1/2009 | | DONE |
Tisha Gallop
|
|
|
picked up approved mechanical plans
|
Plan resubmittals received | | | 3/31/2009 | | |
Tim L. Woodard
|
|
|
Received 2 copies of sheet M1.0 and taken to Tim Woodard's desk///3-31-09 @ 3:10pm BAS
|
FIRE-Final Inspection | 3/24/2009 | 3/25/2009 | 3/25/2009 | A | PASS |
Forrest France
|
|
|
Noted corrections finished, fire life safety passed.
|
Routing - MECHANICAL | 3/23/2009 | | 3/23/2009 | | FAIL |
Troy James
|
|
|
Plans failed sent plan review report.
|
Routing - PLAN CHECK | 3/23/2009 | | 3/23/2009 | | FAIL |
Tim L. Woodard
|
|
|
MECHANICAL PLAN REVIEW
Owner__Luxe'a Nail and Spa
Address__634 E. Boise Ave
Occupancy__B Type of Construction__VB
1. Ventilation requirements for nail salons per IMC Table 403.3, footnote b, states that there shall be no recirculation of air in the space. The intent of the IMC is that the exhaust system shall be at point of service. Please revise plans to show the exhaust system design to each manicure station. Footnote I states that the required exhaust system shall capture the contaminants and odors at their source.
2. Please show on plans, exhaust to exterior per chapter 5 IMC, for product conveying exhaust systems termination requirements.
3. Please show on plans ventilation calculations and make up air design for the exhaust system at manicure stations.
4. Provide section view on plans of exhaust system design at manicure stations.
5. Show on plans ventilation requirements per Table 403.3 for outside air design of 25 cfm per person.
If you have further questions in regards to this review, please contact:
Troy James
###-####
Faxed plans to Tamura
|
FIRE-Final Inspection | 3/19/2009 | 3/20/2009 | 3/20/2009 | A | FAIL |
Forrest France
|
|
|
EM light at the east wall is not functional, provide a current certification tag for the existing fire extinguisher, install approved hardware at the second exit or remove signage.
|
Plan resubmittals received | | | 3/20/2009 | | |
Tisha Gallop
|
|
|
Received two copies of mechanical sheet M1.0; taken to Tim Woodard
|
Override - Parcel Holds | 3/19/2009 | 1/1/1900 | 3/19/2009 | | |
|
|
|
fire life safety
|
Issue PAID IN FULL permit | | | 3/10/2009 | | DONE |
Barbara Stitt
|
|
|
|
Plan assigned to (TLW) | 3/3/2009 | | 3/9/2009 | | PASS |
Tim L. Woodard
|
|
|
3/9/2009 14:57:19 TLW - activity updated through activity BLDA022 from case BLD09-00249.
|
Routing - PLAN CHECK | 3/9/2009 | | 3/9/2009 | | PASS |
Tim L. Woodard
|
|
|
Per Redlines on plans.
|
Routing - FIRE | | | 3/9/2009 | | PASS |
Tim L. Woodard
|
|
|
Field Verify
|
1st review completed | | | 3/9/2009 | | DONE |
Tim L. Woodard
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/9/2009 | | DONE |
Tim L. Woodard
|
|
|
|
Case Summary (BLD) | | | 3/9/2009 | | DONE |
|
|
|
|
Print Occupancy Form | | | 3/9/2009 | | DONE |
|
|
|
|
Telephone call | | | 3/9/2009 | | DONE |
Alexandra L. DeYoung
|
|
|
LM for Doug. permit ready, fees given
|
Permit Ready to Issue | | | 3/9/2009 | | DONE |
Alexandra L. DeYoung
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 3/3/2009 | | DONE |
Barbara Stitt
|
|
|
|
Application received | | 3/2/2009 | 3/2/2009 | | DONE |
Barbara Stitt
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 3/2/2009 | | DONE |
Barbara Stitt
|
|
|
|