Third Notice | | 10/15/2009 | 10/5/2009 | | DONE |
|
|
|
|
Third Notice | | 9/11/2009 | 10/5/2009 | | DONE |
|
|
|
|
Telephone call | | | 10/5/2009 | | DONE |
Tisha Gallop
|
|
|
called and spoke with Sid/Mtn Top Maint. need final values. He said gave to co-worker in office, told him no record so he e-mailed them to me.
|
Third Notice | | 8/11/2009 | 9/11/2009 | | DONE |
|
|
|
|
Second Notice | | 7/22/2009 | 8/11/2009 | | DONE |
|
|
|
|
First Notice | | 6/19/2009 | 7/22/2009 | | DONE |
|
|
|
|
BLD-Final | 6/18/2009 | 6/19/2009 | 6/19/2009 | P | PASS |
Dave Hannah
|
|
|
sid - early afternoon please Phone #: ###-#### ok for perm occ
|
Permanent Occupancy | | | 6/19/2009 | | DONE |
Tisha Gallop
|
|
|
|
FIRE-Final Inspection | 6/16/2009 | 6/17/2009 | 6/17/2009 | A | PASS |
Forrest France
|
|
|
Life safety inspection passed after corrections made while on site including removal of a manual flush bolt at the main entry/exit door. Contractor to post "door to remain......." sign prior to structural final for verification at that time.
|
BLD-Final | 6/16/2009 | 6/17/2009 | 6/17/2009 | P | CANC |
Dave Hannah
|
|
|
Sid Rose Phone #: ###-#### Inspection cancelled from web by: Barbara Stitt
|
BLD-Framing/Rough-in | 5/21/2009 | 5/22/2009 | 5/22/2009 | P | PASS |
Jim Sly
|
|
|
Sid Phone #: ###-####
|
Case Summary (BLD) | | | 5/21/2009 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 5/20/2009 | | DONE |
Tisha Gallop
|
|
|
|
Plan assigned to (TLW) | 4/28/2009 | | 5/19/2009 | | PASS |
Tim L. Woodard
|
|
|
5/19/2009 16:26:18 TLW - activity updated through activity BLDA022 from case BLD09-00600.
|
Routing - MECHANICAL | 5/15/2009 | | 5/19/2009 | | PASS |
Lee Rice
|
|
|
From; Lee Rice
Chief Plumbing and Mechanical Inspector
RE: Letter dated May 15th 2009 in response to Troy James Plan review.
Response to Items #1 and #2 re nail painting exhaust May 15th 2009:
Thank you for designing and providing mechanical plans with your architects stamp. Although not normally accepted in lieu of engineered drawings when required by this office in accordance with IMC section 102.9 and under the authority provided in said section and in accordance with IMC section 103. and 103.2 as the code official I will grant an exception for this one job with the following conditions of approval.
A. At the time of rough-in installation and inspection when the 4" duct length and number of 90 degree elbows is known provide a third party engineered static pressure calc on said 4" exhaust duct system indicating that the fan used (static pressure production) minus the ductwork static pressure drop or losses will remove the required design cfms at the point(s) of use.
B. Be prepared to advice your client that if this design is inadequate a new design requiring larger ducting and fan will be required or a much more expensive 4 inch exhaust fan capable of a high enough static pressure to meet design exhaust requirements will be required to be installed.
Response to Item #3 re dryer exhaust May 15th 2009:
Please be advised that the dryer exhaust duct requirements of IMC section 504.6 and 504.6.1 are prescriptive requirements and take precedence when designing dryer exhaust systems. The exception should only be used when architectural design and location of dryers is determined to be unavoidable to accommodation of the prescriptive requirements of this section. The exception as per code language will only be granted if necessary and the make, model and installation instructions for a compliant dryer are provided to the code official to meet the exception requirement. Also, we know that stack type apartment style dryer units have historically had lower fan exhaust length limitations. Wall labeling is required in some jurisdictions for future owner reference. Please advice your client and installers accordingly.
Thanks you, Lee Rice, Mechanical Code Official.
|
Routing - PLAN CHECK | 5/19/2009 | | 5/19/2009 | | PASS |
Tim L. Woodard
|
|
|
Ok per approval from Mechanical
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/19/2009 | | DONE |
Tim L. Woodard
|
|
|
|
Case Summary (BLD) | | | 5/19/2009 | | DONE |
Tim L. Woodard
|
|
|
|
Print Occupancy Form | | | 5/19/2009 | | DONE |
Tisha Gallop
|
|
|
|
Print Occupancy Form | | | 5/19/2009 | | DONE |
Tisha Gallop
|
|
|
|
Permit Ready to Issue | | | 5/19/2009 | | DONE |
Tisha Gallop
|
|
|
|
Telephone call | | | 5/19/2009 | | DONE |
Tisha Gallop
|
|
|
called Matt Rhees and told him permit is ready, fee and need GC, RCE
|
Routing - PLAN CHECK | 5/13/2009 | | 5/15/2009 | | PEND |
Tim L. Woodard
|
|
|
awaiting approval from mechanical, routed plans back to Troy for review. TLW
|
Plan resubmittals received | | | 5/15/2009 | | DONE |
|
|
|
received 1 review,and 2 copies of sheet A1.0 taken to Tim W.
|
Routing - MECHANICAL | 5/8/2009 | | 5/13/2009 | | FAIL |
Troy James
|
|
|
1. Nail salons are required to be designed and wet stamped by a Mechanical Engineer. I informed this to you over the phone.
2. Provide more information about exhaust fan. I am currently assuming it is an inline fan. What is its cfm capabililty? Can it handle the amount of duct and elbows as shown on plans to exit at roof?
3. Provide with plans dryer manufacturer allowable duct length. If this cannot be obtained at this time, please note on plans dyer specs will be required on site for Mechanical Inspector to review.
|
Routing - MECHANICAL | 4/29/2009 | | 5/8/2009 | | FAIL |
Tim L. Woodard
|
|
|
1. Ventilation requirements for nail salons per IMC Table 403.3, footnote b, states that there shall be no recirculation of air in the space. The intent of the IMC is that the exhaust system shall be at point of service. Please revise plans to show the exhaust system design to show exhaust ducting down at each manicure station.
2. Please show on plans make up air design for the exhaust system at manicure stations in addition to required ventilation as shown on plans.
3. Provide section view on plans of exhaust system design at manicure stations.
4. Provide on plans location of supply and return diffusers.
5. Note on plans how the exhaust system for manicure station will be interlocked, so as to function during business hours.
|
Routing - PLAN CHECK | 5/1/2009 | | 5/8/2009 | | PASS |
Tim L. Woodard
|
|
|
Approved with no comments. TLW
|
1st review completed | | | 5/8/2009 | | DONE |
Tim L. Woodard
|
|
|
|
Routing - FIRE | | | 5/8/2009 | | PASS |
Tim L. Woodard
|
|
|
Field Verify. TLW
|
Plan resubmittals received | | | 5/6/2009 | | DONE |
|
|
|
Received 1 response, and 2 copies of sheet A1.0 taken to Tim W.
|
Routing - PUBLIC WORKS | 4/28/2009 | | 4/29/2009 | | PASS |
Beverly Hall
|
|
|
|
Routing - PLAN CHECK | 4/29/2009 | | 4/29/2009 | | PEND |
Tim L. Woodard
|
|
|
awaiting review from Mechanical.
|
Plans ACCEPTED BY PLAN TECH | | | 4/28/2009 | | DONE |
|
|
|
Ok per Tim W. for level 2 intake
|
Application received | | 4/28/2009 | | | |
|
|
|
|