Permit Information
Permit NumberBLD09-00616
StatusFinaled
Name EKC INC
Site Address 1914 S BROADWAY AVE
Project NameGarfield Elementary
Customer Number 
ePlanReviewNo
Description
(GARFIELD ELEMENTARY SCHOOL - RAMP AND ELEVATOR ADDITIONS) Only the basement of this building is fire sprinklered. To construct an exterior concrete ramp and an interior elevator shaft and elevator to serve an existing elementary school. An existing basement stairway and an existing 2nd story stairway will be eliminated. An existing 1st story stairway will be replaced with a new stairway, about 2 feet narrower than the old one. The new elevator will have 5 stops (basement, lower 1st story, upper 1st story, lower 2nd story, and upper 2nd story). For the exterior concrete ramp, work is to include concrete footings, concrete retaining walls, concrete slabs, metal guards, and metal handrails. For the interior elevator, work is to include a masonry shaft for the elevator, a 1-hr elevator machine room, and smoke control on the elevator doors (the elevator doors will open into existing 1-hr corridors). The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Plan Reviewer's activity  6/21/2010 DONE
Took office copy to Records.
Third Notice 5/17/20105/25/2010 DONE
Third Notice 4/21/20105/3/2010 DONE
faxed
Second Notice 4/8/20104/16/2010 DONE
First Notice3/22/20103/22/20103/29/2010 DONE
DetailsJim Storey
BLD-Aging Inspection3/22/20103/22/20103/22/2010 PASS
DetailsJim Storey
DOC - Permit Finaled3/22/20103/22/20103/22/2010PPASS
DetailsJim Storey
FIRE-Final Inspection1/19/20101/19/20101/19/2010APASS
DetailsForrest France
Fire life safety passed.
Letter of compliance  1/14/2010  
DetailsTisha Gallop
BLD-Final1/13/20101/14/20101/13/2010APASS
DetailsJim Storey
rick- call 30 mins prior to going Phone #: ###-####
FIRE-Final Inspection12/31/20091/4/20101/5/2010PPASS
DetailsForrest France
Fire life safety is acceptable pending one exit sign at the second level elevator lobby is removed- to be verified prior to structural final approval.
BLD-Final1/4/20101/5/20101/5/2010AFAIL
DetailsJim Storey
Rick-Please call at least 30 mins prior to inspection Phone #: ###-#### need plm final/ need s lable on rated doors 2 locations.
BLD-Conference1/5/20101/5/20101/5/2010AFAIL
DetailsBill VanDegrift
work requireing a plumbing permit has been preformed at this address.
1) secure a plumbing permit- attach this permit to bld09-00616.
2)removecast iron 1/4 bends from relocated 2" waste line and replace with S.S. 90 deg.
3) if the condensate from the new ptac unit is piped to a hub drain in the crawlspace, remove the hub drain, cap waste line and pipe condensate to an approved location.
FIRE-Final Inspection12/30/200912/30/200912/30/2009PCANC
DetailsTroy Cobbley
Cancelled due to time constraints.
BLD-Final12/29/200912/30/200912/30/2009PCANC
DetailsJim Storey
Rick Phone #: ###-#### Inspection cancelled from web by: Patricia Smith
FIRE-Final Inspection12/29/200912/30/200912/30/2009APEND
DetailsForrest France
Final pending project related fire alarm permit.
FIRE-Final Inspection12/7/200912/8/200912/9/2009PNR
DetailsForrest France
See fire code review notes items # 19 and 21. Also IFC 2006 sec. 907.3, 907.3.1.1, 907.2.3, and 903.4.
Zoning Approval11/10/200911/10/200911/10/2009 PASS
DetailsSarah Schafer
FIRE-Conference11/4/200911/4/200911/4/2009PDONE
DetailsForrest France
Some issues noted during the project related fire sprinkler cover inspection include: missing electrical supervision of the main control valve for the existing riser-see fire code review note #21, also verify system is current with an annual certification-see note #17, complete protection for the basement per NFPA 13 shall be provided-see note #13- per NFPA 13 2007 sec. 8.6.7.1 sprinklers shall be required in all ceiling pockets unless exceptions 1-7 are met per 8.6.7.2 including item (2) depth of the unprotected pocket does not exceed 36" and item (7) quick response sprinklers are provided throughout the compartment. See also project related fire alarm permit FIR09-00418 review comments items #19, and 6,7, 12 regarding locations of smoke and heat detectors, in particular item #11 referencing NFPA 72 2007 sec. 6.16.4.2 stating heat detectors used for elevator power shut down shall be placed within 2ft of each sprinkler head and be installed per requirements of Chapter 5.
BLD-Other11/2/200911/3/200911/3/2009APASS
DetailsJim Storey
rick - ceiling cover Phone #: ###-#### ok pending others
FIRE-Conference11/2/200911/2/200911/2/2009PDONE
DetailsForrest France
On site visit regarding project attatched fire alarm and sprinkler permit work including coverage at the elevator machine room, monitoring for the existing fire sprinkler riser, fire code review notes, location of the new panel, NFPA 13 and 72 requirements.
BLD-Aging Inspection10/29/200910/29/200910/29/2009 PASS
DetailsJim Storey
wip
BLD-Framing/Rough-in8/24/20098/25/20098/25/2009APASS
DetailsMike Jordan
Rick Phone #: ###-####. Reviewed engineering from Calls engineering on attachment for stair stringer and steel studwall.
BLD-Framing/Rough-in8/21/20098/24/20098/24/2009ACANC
DetailsDave Hannah
rick - please call 1/2 hr prior Phone #: ###-####
BLD-Framing/Rough-in8/18/20098/19/20098/19/2009PPART
DetailsJim Storey
rick Phone #: ###-#### need resolve from mti meetting for epoxy report failled/ ok to gyp all areas but stair stringer wall until support for wall is provited/ tread width needs to be min 11 inches nose to nose.
BLD-Framing/Rough-in8/6/20098/6/20098/6/2009PPASS
DetailsJim Storey
Rick Phone #: ###-#### framing at top of elevator shaft ok headers in walls 1 & 2 ok to cover.
BLD-Framing/Rough-in7/29/20097/30/20097/30/2009PPASS
DetailsJim Storey
Rick Phone #: ###-####
Issue PAID IN FULL permit  6/12/2009  
DetailsAlexandra L. DeYoung
Inspection Record Card- Bld  6/1/2009 DONE
Details
Telephone call  6/1/2009 DONE
Details
left message with margie for jimmy o'connor at ###-#### - permit ready and fees given - also need gc name, rce# and rp name
Permit Ready to Issue  6/1/2009 DONE
Details
Routing - PLAN CHECK5/11/2009 5/29/2009 PASS
DetailsCarl Westfall
Drawings approved, with added Plan Review notes, after resubmittal review.
PLANS/APPL TAKEN TO FRONT DESK  5/29/2009  
Plan assigned to (CJW)4/30/2009 5/29/2009 PASS
DetailsCarl Westfall
5/29/2009 13:56:01 CJW - activity updated through activity BLDA022 from case BLD09-00616.
Plan resubmittals received  5/21/2009  
DetailsTisha Gallop
Received transmittal, Addendum #1, response to plan review report, two copies of ICC Evaluation Report for Smoke Curtains, Info on Non-Fire rated smoke doors, plan sheets A2.3, A2.4, A2.5, A2.6, EX.B, EX.1, EX.2; taken to Carl Westfall
Routing - FIRE5/6/20095/6/20095/11/2009 PASS
DetailsScott Arellano
Attached IFC comments to plans
1st review completed  5/11/2009 FAIL
Failed Plan Check
Route to Impact Fee Review5/6/20095/11/20095/6/2009 PASS
DetailsCindy M. Gould
Tenant improvement no fees.
Routing - PLAN CHECK4/30/2009 5/6/2009 FAIL
DetailsCarl Westfall
The IBC plan review was started on May 1, 2009 and was finished on May 6, 2009 (4 work days). Revised and new drawings and information was required. See the plan review report.
Application received 4/29/20094/30/2009 DONE
DetailsBarbara Stitt
Routing - Erosion and Sediment4/30/2009 4/30/2009 PASS
DetailsSteven Webb
ESC plan waiver approved with attached conditions. ESC09-00219
Pending Assignment by JCB4/30/2009 4/30/2009 DONE
DetailsJason Blais
Routing - Design Review4/30/2009 4/30/2009 PASS
DetailsSarah Schafer
Sarah Schafer. Approved. project meets all setback requirements for the zone.
Recd Pcfee & Taken To Pln CK  4/29/2009 DONE
DetailsBarbara Stitt
Plans ACCEPTED BY PLAN TECH  4/29/2009 DONE
DetailsBarbara Stitt