Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD09-01779
StatusFinaled
Name CENTIMARK CORP
Site Address 901 N CURTIS RD
Project Name 
Customer Number 
ePlanReviewNo
Description
Overlay of existing BUR roof system with 1/2" fiberboard recovery board fully adhered with OlyBond 500 then IPO fully adhered with bonding adhesive. Existing roof sysem was inspected with IR scan to identify areas of wet insulation which were then verified with core cuts. New roof system to be installed per FM Global 1-60 specifications. Value is 48,000 per initial cert of value
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/8/20101/8/20101/8/2010APASS
DetailsTom Arcoraci
DOC - Permit Finaled1/8/20101/8/20101/8/2010PPASS
DetailsTom Arcoraci
BLD-Aging Inspection1/8/20101/8/20101/8/2010 PASS
DetailsTom Arcoraci
Issue & PRINT to be Invoiced  10/9/2009 DONE
Details
First Notice1/8/20101/8/2010   
DetailsTom Arcoraci
Application received 10/9/2009