Permit Information
Permit NumberBLD10-00886
StatusFinaled
Name EXCELSIOR CONSTRUCTION CO
Site Address 3434 W PASADENA DR
Project NameOWYHEE ELEMENTARY
Customer Number 
ePlanReviewNo
Description
(OWYHEE ELEMENTARY SCHOOL - KITCHEN REMODEL) This building is NOT fire sprinklered. To remodel the 970 square foot kitchen in an existing elementary school. Work is to include interior nonbearing walls (masonry and steel stud), a steel header over a new 14 foot long opening in an existing masonry bearing wall, a 14 foot long roll-up door at the food service tray slide, a Type II dishwasher hood, a Type II kitchen hood over food preparation equipment, a 1,500 gallon grease trap, a new concrete floor slab and patches in the existing slab, a walk-in cooler, a walk-in freezer, suspended ceiling, and interior finishes. Interior nonstructural demolition is also covered under this permit. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 4/5/20114/15/2011 DONE
Second Notice 3/27/20113/31/2011 DONE
First Notice 3/11/20113/17/2011 DONE
CDHD Occupancy Approval3/1/20113/1/20113/1/2011 DONE
DetailsBarbara Stitt
Phone call from Bud Fullerton on 3-1-11 ok for Perm Occupancy
Permanent Occupancy  3/1/2011 DONE
DetailsBarbara Stitt
BLD-Aging Inspection2/28/20112/28/20112/28/2011 PASS
DetailsTom Arcoraci
Print Occupancy Form  2/28/2011 DONE
BLD-Aging Inspection12/28/201012/28/201012/28/2010 PASS
DetailsTom Arcoraci
BLD-Aging Inspection10/25/201010/25/201010/25/2010 PASS
DetailsTom Arcoraci
Telephone call  8/27/2010 DONE
Bud from CDHD called and gave the ok for final
FIRE-Final Inspection8/23/20108/23/20108/23/2010PPASS
DetailsForrest France
Fire life safety passed.
BLD-Final8/19/20108/23/20108/23/2010PPASS
DetailsTom Arcoraci
chris Phone #: ###-####
FIRE-Final Inspection8/20/20108/20/20108/20/2010PPART
DetailsForrest France
Completed project related fire alarm permit inspection for the new duct detector.
FIRE-Final Inspection8/20/20108/20/20108/20/2010ANR
DetailsForrest France
BLD-Framing/Rough-in7/21/20107/21/20107/21/2010PPART
DetailsTom Arcoraci
Chris Phone #: ###-#### walls ok
BLD-Foundation7/8/20107/9/20107/9/2010APASS
DetailsTom Arcoraci
Chris Phone #: ###-####
Issue PAID IN FULL permit  6/23/2010 DONE
DetailsBarbara Stitt
Routing - MECHANICAL6/9/2010 6/9/2010 PASS
DetailsTroy James
Routing - PLAN CHECK6/9/2010 6/9/2010 DONE
DetailsCarl Westfall
PLANS/APPL TAKEN TO FRONT DESK  6/9/2010 DONE
Print Occupancy Form  6/9/2010 DONE
Telephone call  6/9/2010 DONE
t/c w greg at ###-#### - permit ready and fees given - also need gc name and rce#
Permit Ready to Issue  6/9/2010 DONE
Plan assigned to (CJW)4/27/2010 6/9/2010 PASS
DetailsCarl Westfall
6/9/2010 13:56:12 CJW - activity updated through activity BLDA022 from case BLD10-00886.
Routing - PLAN CHECK5/27/2010 6/9/2010 PASS
DetailsCarl Westfall
Completed the IBC resubmittal review. Drawings approved.
Plan resubmittals received  6/2/2010  
DetailsCarl Westfall
rec'd calcs and two copies of sheets A0.0; A0.1; A1.0; A2.0; A3.0; A3.1; A4.0; A5.0; A6.0; A7.0; M1.0; M2.1; M2.2; M3.1; M3.2; M3.3; E1.0; E2.0; taken to Carl W
Routing - FIRE5/25/20105/25/20105/27/2010 PASS
DetailsScott Arellano
Please, see attached comments.
1st review completed  5/27/2010 DONE
Failed - Plan Check, Mechanical,
Route to Impact Fee Review5/25/20105/28/20105/26/2010 PASS
DetailsCindy M. Gould
No impact fees for remodel
Routing - PLAN CHECK5/4/2010 5/25/2010 FAIL
DetailsCarl Westfall
The IBC plan review was started on May 18, 2010 and was finished on May 25, 2010. Some structural issues are yet to be resolved. See the plan review report.
Routing - MECHANICAL5/3/2010 5/4/2010 FAIL
DetailsTroy James
1. Explain on plans how you are going to provide 1085 cfm of additional make-up air needed.
2. Note on plans steel grease duct on roof shall be painted.
3. Detail A sheet A3.0 does not show we will have 18" clearance to combustible ceiling. Please verify if this is a problem that needs to be addressed now.
4. Same detail shows incorrect method of installing grease ducts. Revise detail or provide note refer to roof plan for proper grease duct installation.
5. The type of exhaust fan shown on schedule for type 1 hood appears to be an upflow type. Detail A sheet A3.0 shows and adjacent roof slope within 10 feet of exhaust fan. IMC 506.3.12.3 states the exhaust outlets shall be located 10 feet away from adjacent building.
6. Note on plans air balance report is required and on site for final mechanical inspection.
7. There is no mention on plans Grease duct clearances and protection to combustible construction. Am I to assume we have 18" clearance to combustibles.
Routing - PLUMBING4/29/2010 5/3/2010 PASS
DetailsBill VanDegrift
Have Troy James review the Mechanical after Plumbing review. additional cross connection protection may be required. per plans and 2003 upc
Routing - Erosion and Sediment4/28/2010 4/29/2010 PASS
DetailsSteven Webb
ESC10-00338 plan waiver approved with attached conditions.
Routing - PUBLIC WORKS4/27/2010 4/28/2010 PASS
DetailsBeverly Mountain
Routing PW Environmental4/28/2010 4/28/2010 PASS
DetailsWalt Baumgartner
Located in Bench Sewer District. Plans revwd, 1500 gallon grease interceptor for kitchen drainage noted.
Pending Assignment by JCB4/26/2010 4/27/2010 DONE
DetailsJason Blais
Routing - Addressing4/27/2010 4/27/2010 PASS
DetailsApril Wing
Plans ACCEPTED BY PLAN TECH  4/26/2010 DONE
ok per Carl Westfall to take in as a level 3
Recd Pcfee & Taken To Pln CK  4/26/2010 DONE
Application received 4/23/20104/23/2010 DONE
DetailsDarla L Downs
Intake Approval  4/23/2010 PASS