Third Notice | | 5/30/2011 | 6/7/2011 | | DONE |
|
|
|
|
Second Notice | | 5/20/2011 | 5/25/2011 | | DONE |
|
|
|
|
First Notice | | 5/6/2011 | 5/10/2011 | | DONE |
|
|
|
|
BLD-Final | 4/25/2011 | 4/26/2011 | 4/27/2011 | P | PASS |
Jim Sly
|
|
|
gail Phone #: ###-#### OK for Perm Occ.
|
FIRE-Final Inspection | 4/25/2011 | 4/26/2011 | 4/26/2011 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed
|
Permanent Occupancy | | | 4/26/2011 | | DONE |
Tisha Gallop
|
|
|
SEND FINAL VALUE NOTICE TO PARCEL OWNER AT THE PO BOX ADDRESS
|
BLD-Final | 4/18/2011 | 4/18/2011 | 4/18/2011 | P | FAIL |
Mike Jordan
|
|
|
gale Phone #: ###-####. Needs fire/life/safety final. Provide smoke and flame spread for insulation on walk in cooler. Provide the sticker above the main door. Approved plans show exisiting restroom to be remodled and upgraded to meet ICC ANSI standards as required per the 20% rule. Restroom as is is non compliant.
|
BLD-Framing/Rough-in | 2/25/2011 | 2/28/2011 | 2/28/2011 | P | PASS |
Jim Sly
|
|
|
cail - cover inspection Phone #: ###-####
|
Override - Parcel Holds | 2/25/2011 | 1/1/1900 | 2/25/2011 | | |
|
|
|
cover inspection
|
BLD-Concrete | 2/18/2011 | 2/22/2011 | 2/22/2011 | A | PASS |
Jim Sly
|
|
|
###-#### Gail
|
BLD-Framing/Rough-in | 2/18/2011 | 2/22/2011 | 2/22/2011 | A | PART |
Jim Sly
|
|
|
###-####-Gail Post and beam OK
|
OVERRIDE | | | 2/22/2011 | | |
|
|
|
|
CHANGE STATUS TO (ISS) | | | 2/22/2011 | | DONE |
Barbara Stitt
|
|
|
Issue plan modification 2-22-11
|
(F) Reprint permit | | | 2/22/2011 | | DONE |
Barbara Stitt
|
|
|
|
Override - Parcel Holds | | | 2/22/2011 | | |
|
|
|
|
Override - Parcel Holds | | | 2/18/2011 | | |
|
|
|
|
Override - Parcel Holds | | | 2/18/2011 | | |
|
|
|
|
Override - Parcel Holds | | | 2/18/2011 | | |
|
|
|
|
Override - Parcel Holds | | | 2/18/2011 | | |
|
|
|
|
Plan assigned to (CDM) | 2/11/2011 | 2/11/2011 | 2/14/2011 | | DONE |
Carl D Madsen
|
|
|
|
Routing - PLAN CHECK | 2/14/2011 | | 2/14/2011 | | PASS |
Carl D Madsen
|
|
|
|
Case Summary (BLD) | | | 2/14/2011 | | DONE |
|
|
|
|
Print Occupancy Form | | | 2/14/2011 | | DONE |
|
|
|
|
Telephone call | | | 2/14/2011 | | DONE |
|
|
|
2-14-11 called Bob permit ready and fee given ///dld
|
Plan Modification Accepted | | | 2/11/2011 | | DONE |
|
|
|
Plan modification excepted for BLD10-01926 to add a non -load bering wall in stgorage. Reduce size of room 103. Redesign HVAC for different heating unit. pages affected are A2.1,H1.0
|
BLD-Conference | 2/1/2011 | 1/28/2011 | 2/1/2011 | A | DONE |
Jim Sly
|
|
|
###-#### Gail Arnold
|
CHANGE STATUS TO (ISS) | | | 2/1/2011 | | DONE |
Christina Prado
|
|
|
Plan mod paid for and permit re-issued
|
OVERRIDE | | | 1/19/2011 | | |
|
|
|
|
Plan assigned to (CDM) | 1/14/2011 | 1/14/2011 | 1/19/2011 | | PASS |
Carl D Madsen
|
|
|
|
Routing - PLAN CHECK | 1/14/2011 | | 1/19/2011 | | PASS |
Carl D Madsen
|
|
|
|
Case Summary (BLD) | | | 1/19/2011 | | DONE |
|
|
|
|
Print Occupancy Form | | | 1/19/2011 | | DONE |
|
|
|
|
Telephone call | | | 1/19/2011 | | DONE |
Barbara Stitt
|
|
|
Called Bob Camp and told him that this permit is ready & Fees due on 1-19-11 @ 11:10am
|
Plan Modification Accepted | | | 1/14/2011 | | DONE |
|
|
|
1-14-11 Plan modification excepted for BLD10-01926 to change non-load brg to 34'' half wall. move cabinet to other side of wall. No tile in stor,(102) or prep.(103) - Burnished conc. pages affected A2.1 & A5.1
|
Issue PAID IN FULL permit | | | 1/12/2011 | | DONE |
Christina Prado
|
|
|
|
Permit Ready to Issue | | | 12/16/2010 | | DONE |
|
|
|
|
Telephone call | | | 12/16/2010 | | DONE |
|
|
|
12-16-10 called Bob Camp permit ready and fee given . Also need GC & RP ///dld
|
Plan assigned to (CDM) | 8/27/2010 | 8/27/2010 | 12/15/2010 | | PASS |
Carl D Madsen
|
|
|
|
Routing - PLAN CHECK | 12/15/2010 | | 12/15/2010 | | PASS |
Carl D Madsen
|
|
|
|
Routing - FIRE | | | 12/15/2010 | | PASS |
|
|
|
Verify in field CDM
|
Case Summary (BLD) | | | 12/15/2010 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/15/2010 | | |
|
|
|
|
Print Occupancy Form | | | 12/15/2010 | | DONE |
|
|
|
|
Plan resubmittals received | | | 12/9/2010 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 12/9/2010 | | 12/9/2010 | | FAIL |
Carl D Madsen
|
|
|
Cooler wall have not been properly addressed. Replyed in an E-mail to Bob Camp at Habitech 12-9-10 CDM
|
Plan resubmittals received | | | 12/9/2010 | | DONE |
|
|
|
received 2 copies of sheet A2.1 taken to Carl M.
|
Routing - PLANNING | 11/18/2010 | | 11/18/2010 | | PASS |
Josh Wilson
|
|
|
OK per revised drawings
|
Routing - PLAN CHECK | 11/18/2010 | | 11/18/2010 | | FAIL |
Carl D Madsen
|
|
|
Cooler wall submittals do not comply with the code 11-18-10 CDM
Talked to Bob Camp at Habitec and asked for resubmittals.
|
Routing - PLAN CHECK | 9/16/2010 | | 11/16/2010 | | FAIL |
Carl D Madsen
|
|
|
|
Plan resubmittals received | | | 11/9/2010 | | |
Barbara Stitt
|
|
|
RECEIVED 2 COPIES OF SHEETS a0.0, a2.1, a2.2, a5.1 and inserted into plans by Habitec then returned to Carl's desk on 11-9-10 @ 4:45pm
|
Routing - PLUMBING | 9/15/2010 | | 9/16/2010 | | PASS |
Bill VanDegrift
|
|
|
RPBO-1 needs to be installed upstream of filter system. vent kitchen FD-1.
|
Routing - PLANNING | 9/15/2010 | | 9/15/2010 | | PASS |
Josh Wilson
|
|
|
|
1st review completed | | | 9/1/2010 | | FAIL |
|
|
|
|
Routing - PUBLIC WORKS | 8/27/2010 | | 9/1/2010 | | PASS |
Connie Baumgartner
|
|
|
|
Routing PW Sewer Rating | 9/1/2010 | | 9/1/2010 | | PASS |
Connie Baumgartner
|
|
|
|
Routing - Addressing | 8/31/2010 | | 8/31/2010 | | PASS |
Terry Records
|
|
|
|
Routing PW Environmental | 8/31/2010 | | 8/31/2010 | | PASS |
Walt Baumgartner
|
|
|
Car wash being demo'd. New kitchen area notes 1000 gallon approved grease interceptor, OK
|
Recd Pcfee & Taken To Pln CK | | | 8/27/2010 | | DONE |
|
|
|
|
Intake Approval | | | 8/13/2010 | | PASS |
|
|
|
Needs central district health and ESC with waiver letter
|
Application received | | 8/13/2010 | | | |
|
|
|
|
Routing - PLAN CHECK | 9/1/2010 | | | | FAIL |
Carl D Madsen
|
|
|
|