Permit Information
Permit NumberBLD10-02170
StatusFinaled
Name HANDYMAN CONNECTION
Site Address 4714 W STATE ST
Project NameCOLLISTER SHOPPING CENTER
Customer Number 
ePlanReviewNo
Description
(GREEN CHUTES & SALT TEARS COFFEE SHOP) One-hr construction and fire sprinklers are used for building area increase. To remodel an existing 11,236 square foot tenant space (total of 11,566 square feet after a 330 square foot mezzanine is constructed) for a restaurant and retail sales tenant. No cooking operations that create grease laden vapors are allowed within this tenant space or under the canopy. The proposed BBQ is required to be located outside of this building in an area that is open to the sky. Work is to include two restrooms accessible to the disabled, interior nonbearing partitions, four 160 square foot shipping containers to function as rooms, ramps and landings to provide access to the shipping containers, millwork, interior finishes, dining tables and chairs, service counters, a Type II hood, and kitchen equipment. The shipping containers are to have the doors welded in the open position. Mezzanine work includes wood stud bearing walls, gypsum board shear walls, wood floor joists, and wood floor sheathing. The mezzanine floor and the supporting walls are required to be of 1-hr fire-resistance-rated construction. Mezzanine stairway work includes steel stringers, steel columns, steel beams, and steel treads. This building is required to be maintained as a Type V-A building (i.e. 1-hr fire-resistance-rated). Work includes removing the existing suspended 1-hr ceiling and creating a 1-hr fire-resistance-rated roof-ceiling assembly using a gypsum board membrane. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to be maintained in compliance with NFPA 13 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
(F) Reprint permit  8/28/2012 DONE
DetailsBarbara Stitt
Case Summary (BLD)  8/28/2012  
Case Summary (BLD)  8/28/2012  
First Notice 1/23/20111/31/2011 DONE
BLD-Final1/13/20111/13/20111/13/2011PPASS
DetailsMike Jordan
ok for perm occ.
BLD-Final1/12/20111/13/20111/13/2011APART
DetailsMike Jordan
Call 30 min prior--Karen Phone #: ###-####. Ok for Temp occ. Need final letter from special inspection agency.
FIRE-Final Inspection1/12/20111/13/20111/13/2011APASS
DetailsTroy Cobbley
Life safety passed
Permanent Occupancy UNPAID FEE  1/13/2011 DONE
DetailsTisha Gallop
Meeting  1/13/2011 DONE
DetailsTisha Gallop
When General Contractor was in office getting C of O said to send request for final values to applicant Travis Shain/Collister Shopping Center or representative Christophe Guigon/Guigon Olson Studios because GC doesn't know $ for parts he was not involved in.
FIRE-Conference1/10/20111/10/20111/10/2011PDONE
DetailsTroy Cobbley
Carl Westfall is ok with the exit sign that was shown to be installed at the top of the stairs to the mezzanine to be deleted.
FIRE-Conference1/7/20111/7/20111/7/2011PDONE
DetailsTroy Cobbley
I went over life safety requirements prior to the final inspection. This included verifying that the existing exit discharge lights still function, verifying the new exit signs/emergency lights work, tagging the fire exitinguishers and providing the correct occupant load sign for the coffee shop.
BLD-Other1/5/20111/6/20111/7/2011APART
DetailsTony Young
Dave Phone #: ###-####,, final walk through conf.
BLD-Framing/Rough-in12/14/201012/15/201012/14/2010APASS
DetailsTony Young
dave Phone #: ###-####,, bathroom frame ok
BLD-Final12/13/201012/14/201012/14/2010ANR
DetailsTony Young
dave Phone #: ###-####,, not a final,, bathroom frame ok
BLD-Conference11/29/201011/29/201012/7/2010PPART
DetailsTony Young
Mark Phone #: ###-####,, fire blocking in tall wall ok
BLD-Framing/Rough-in11/23/201011/24/201012/2/2010APART
DetailsTony Young
Mark Phone #: ###-####,, conf only on framing
BLD-Framing/Rough-in11/22/201011/22/201011/24/2010PPART
DetailsTony Young
Mark Phone #: ###-####,, last of ceiling ok
BLD-Wall cover11/17/201011/18/201011/18/2010APART
DetailsJim Sly
mark Phone #: ###-####
On going Ceiling insp....OK
BLD-Framing/Rough-in11/16/201011/17/201011/17/2010APART
DetailsTony Young
mark Phone #: ###-####,, work in progress,, tune sheetrocker up on screw patterns, laps on base and face layer,, contractor is applying a 20 min rating on finished product
BLD-Wall cover11/12/201011/15/201011/15/2010APASS
DetailsDave Hannah
Mark,, ###-####,, ceiling layer first and second layers look ok beams also ok crew is about 25 % done with ceiling
BLD-Wall cover11/9/201011/10/201011/15/2010PPART
DetailsTony Young
###-####,, ceiling layer,, work in progress
BLD-Framing/Rough-in11/9/201011/10/201011/12/2010APART
DetailsTony Young
###-####,, working on west side
BLD-Wall cover11/10/201011/12/201011/12/2010APART
DetailsTony Young
###-####,, 1st ceiling layer on west/north side ok
BLD-Framing/Rough-in11/8/201011/9/201011/12/2010PPART
DetailsTony Young
###-####,, work in progress on draft stops,, and first layer,,
BLD-Framing/Rough-in11/3/201011/8/201011/8/2010APART
DetailsTony Young
Larry Phone #: ###-####,, hat channel,, work in progress,, I requested contractor to get a conf on mechanical and sprinkler for inspection prior to cover ceiling
BLD-Framing/Rough-in11/3/201011/3/201011/4/2010PPART
DetailsTony Young
Larry Phone #: ###-####,, ok to put hat channel up on ceiling area
Print Occupancy Form  11/2/2010 DONE
Telephone call  11/2/2010 DONE
DetailsBarbara Stitt
Told Corrin permit is ready, fees due, need ACHD info & GC info on 11-2-10 @ 1:50pm
Permit Ready to Issue  11/2/2010  
Issue PAID IN FULL permit  11/2/2010 DONE
DetailsBarbara Stitt
Routing - PLAN CHECK10/29/2010 11/1/2010 DONE
DetailsCarl Westfall
PLANS/APPL TAKEN TO FRONT DESK  11/1/2010 DONE
Plan assigned to (CJW)9/16/2010 11/1/2010 PASS
DetailsCarl Westfall
1st review done
Routing - PLUMBING10/28/2010 10/29/2010 PASS
DetailsBill VanDegrift
r.p. required on espresso mechine. additional cross connection protection may be required. verify grease abatement with sewer dist. prior construction.
Routing - FIRE10/27/2010 10/28/2010 PASS
DetailsScott Arellano
Attached IFC comments to plans
Routing - Design Review10/28/2010 10/28/2010 PASS
DetailsSarah Schafer
Approved per CZC10-00192. SMS
Routing - PLANNING10/25/2010 10/27/2010 FAIL
DetailsSarah Schafer
New glass overhead door

I called Christophe Gougin and left a message telling him we would need a zoning certificate for the overhead door installation.
Routing - PLAN CHECK10/12/2010 10/25/2010 PASS
DetailsCarl Westfall
Drawings approved after the resubmittal review.
Plan resubmittals received  10/18/2010 DONE
DetailsTisha Gallop
received two copies of Plan Review Response 1, Plan Review Response 2, supplemental structural calculations, plan sheets Cover, A0.1, A1.0, A1.2, A2.1, A4.0; taken to Carl Westfall.
Routing - FIRE10/6/201010/6/201010/12/2010 FAIL
DetailsScott Arellano
Emailed resubmittal items to architect.
1st review completed  10/12/2010 FAIL
Failed Plumbing, Plan Check, Fire
Route to Impact Fee Review10/6/201010/11/201010/7/2010 PASS
DetailsCindy M. Gould
Tenant improvement no impact fees
Routing - PLAN CHECK9/21/2010 10/6/2010 FAIL
DetailsCarl Westfall
The IBC plan review was started on September 30, 2010 and was finished on October 6, 2010. Revised drawings were required. See the plan review report.
Plan resubmittals received  9/30/2010 
DetailsBarbara Stitt
Received 3 copies of sheet P1.0 & P2.0 and taken to Carl Westfall
Routing - PLUMBING9/20/2010 9/21/2010 FAIL
DetailsBill VanDegrift
additional cross connection protection may be required. provide a plumbing plan for the cafe.
Routing - PUBLIC WORKS9/16/2010 9/20/2010 PASS
DetailsBeverly Mountain
Routing PW Sewer Rating9/20/2010 9/20/2010 PASS
DetailsConnie Baumgartner
Routing - Addressing9/17/2010 9/17/2010 PASS
DetailsApril Wing
Pending Assignment by JCB9/15/2010 9/16/2010 DONE
DetailsJason Blais
Plan Reviewer's activity  9/16/2010 DONE
DetailsJason Blais
Emailed architect Steve Trout. Because this project is a partial change in occupancy, Steve needs to contact ACHD for any requirements or evaluation of any impact fees. Written verification from ACHD will need to be provided to our Permit Counter prior to permit issuance.
Plans ACCEPTED BY PLAN TECH  9/15/2010 DONE
ok per Tim Woodard for level 3 intake
Application received 9/10/2010