Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberBLD10-02989
StatusFinaled
Name AVEST LIMITED PARTNERSHIP
Site Address 8757 W EMERALD
Project NameTRINITY HEALTH
Customer Number 
ePlanReviewNo
Description
(TRINITY HEALTH) (3-7-11 Plan Modification to include a furniture plan and to show electrical, lighting, and plumbing changes). The fire sprinkler system is used for building area increase. To create a 24,796 square foot office tenant space within an existing 33,000 square foot, 1 story building. Work is to include interior nonbearing walls, modified suspended ceilings, interior doors with sidelights, interior doors, and finishes. In addition, a new 5 foot opening will be created in an existing interior wood shear wall. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. A "vanilla finish" permit (BLD10-02988) for the adjacent tenant space is included on the same drawings. An interior nonstructural demolition permit (BLD10-02923) and a partial permit (BLD10-02987) have also been issued. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 5/30/20116/13/2011 DONE
First Notice 5/30/20115/20/2011 DONE
DetailsChristina Prado
Received 5/20/11
BLD-Final5/9/20115/10/20115/9/2011APASS
DetailsMike Jordan
john Phone #: ###-####. ok for perm. occ.
Permanent Occupancy  5/9/2011 DONE
DetailsChristina Prado
BLD-Final4/4/20114/5/20114/5/2011APART
DetailsMike Jordan
john Phone #: ###-####. Temp occ. granted. Will be ok for perm occ. once electrical signs off perm.
FIRE-Final Inspection4/4/20114/5/20114/5/2011APASS
DetailsTroy Cobbley
life safety passed.
Zoning Approval4/5/20114/5/20114/5/2011 DONE
DetailsCody Riddle
Zoning approval not required. CER 4/5/11
Temporary Occupancy UNPAID FEE  4/5/2011 DONE
DetailsChristina Prado
Temporary Occupancy UNPAID FEE  4/5/2011 DONE
DetailsChristina Prado
FIRE-Final Inspection4/4/20114/4/20114/4/2011PCANC
DetailsTroy Cobbley
duplicate inspection.
FIRE-Final Inspection4/4/20114/4/20114/4/2011PFAIL
DetailsTroy Cobbley
Repair the inoperative exit sign in the break room and repair the inoperative lense in the emergency light in the south vestible.
FIRE-Final Inspection3/31/20114/1/20114/1/2011AFAIL
DetailsTroy Cobbley
The arrrows on the exit signs need to be "punched out", exit signs relocated and additional exit signs installed as per the city approved plans. The push to exit buttons need to be provided at the two west exterior exit doors.
BLD-Final3/31/20114/1/20114/1/2011PNR
DetailsTom Arcoraci
late pm please//John Phone #: ###-####
Zoning Approval3/31/20113/31/20113/31/2011 DONE
DetailsDavid Moser
Office in M-1D/ Office use previously approved. No change to the existing site / landscaping and no new planning approval was required.
BLD-Framing/Rough-in3/8/20113/8/20113/8/2011PPART
DetailsMike Jordan
john Phone #: ###-####. Ceiling grid at new offices only. Remainder of grid is existing.
Plan assigned to (CJW)3/4/20113/4/20113/7/2011 PASS
DetailsCarl Westfall
Routing - PLAN CHECK3/4/2011 3/7/2011 PASS
DetailsCarl Westfall
Approved the Plan Modification.
PLANS/APPL TAKEN TO FRONT DESK  3/7/2011 DONE
Print Occupancy Form  3/7/2011 DONE
DetailsBarbara Stitt
Permit Ready to Issue  3/7/2011 DONE
DetailsBarbara Stitt
Telephone call  3/7/2011 DONE
DetailsBarbara Stitt
Left a voice message for Hal Hofheins that permit is ready & fees due on 3-7-11 @ 10:50am///BAS
CHANGE STATUS TO (ISS)  3/7/2011 DONE
(F) Reprint permit  3/7/2011 DONE
Plan Modification Accepted  3/4/2011 DONE
DetailsChristina Prado
Plan Modification accepted for 8757 W Emerald BLD10-02989. Plan Mod for Electrical, Lighting and Plumbing changes and a change in the furniture plan; submitted on A210, P100, E001, E100 and E200;Routed to Carl Westfall
FIRE-Conference3/3/20113/3/20113/3/2011ADONE
DetailsTroy Cobbley
I spoke to the job super intendant about that it appears that there will be significant changes in the sprinkler plans that will require resubmittals/plan modifications.
BLD-Framing/Rough-in2/23/20112/23/20112/23/2011PPASS
DetailsMike Jordan
additional structural support//Jon Phone #: ###-####. Visually inspected the structural upgrade work to the roof joist for additional rtu unit. All work was done per RFI from structural engineer of record.
BLD-Framing/Rough-in2/11/20112/11/20112/11/2011PPART
DetailsMike Jordan
jon Phone #: ###-####. Interior steel stud framing for a managers office that was moved. Needs to sumbit plan modification showing the new office location as well as the vestibule on vanilla finsh side. Contractors was notified.
BLD-Framing/Rough-in2/4/20112/7/20112/7/2011PPASS
DetailsMike Jordan
John Phone #: ###-####. Interior steel stud walls only.
Issue PAID IN FULL permit  2/4/2011 DONE
DetailsChristina Prado
Plan assigned to (CJW)1/3/2011 2/3/2011 PASS
DetailsCarl Westfall
1st review done
Routing - PLAN CHECK1/31/2011 2/3/2011 PASS
DetailsCarl Westfall
Drawings approved after resubmittal review.
PLANS/APPL TAKEN TO FRONT DESK  2/3/2011 DONE
Print Occupancy Form  2/3/2011 DONE
Permit Ready to Issue  2/3/2011 DONE
DetailsTisha Gallop
Telephone call  2/3/2011 DONE
DetailsTisha Gallop
called Radix Const. told him permit is ready and fees.
Routing - PLAN CHECK1/18/2011 1/31/2011 FAIL
DetailsCarl Westfall
Completed the resubmittal review. One item remained unresolved. Sent E-mail to the Architect, etc.
Telephone call  1/31/2011 DONE
Called Mark Gordon with "Red Built" and called Bob Peters (Project Structural Engineer) to discuss the capacity of the existing roof joists. He said he would ask the contractor to get the as built roof design so the actual capacity of the roof joists can be determined.
Telephone call  1/31/2011 DONE
Called Hal Hofheins, Architect, and left a message. Told him that the actual capacity of the roof joists need to be determined. To do this, the original as-builts are required.
Plan resubmittals received  1/25/2011 DONE
DetailsChristina Prado
Received 2 sets of structural calcs, 2 sets of HVAC Load Analysis packets, and 2 sets of plans A200, A310, M100, M200, E100 & E300. Routed to Carl Westfall for review.
Route to Impact Fee Review1/14/20111/19/20111/19/2011 PASS
DetailsCindy M. Gould
Tenant improvement no impact fees
Routing - FIRE1/14/20111/14/20111/18/2011 PASS
DetailsScott Arellano
Attached IFC comments to plans
1st review completed  1/18/2011 FAIL
Failed Plan Check
Routing - PLAN CHECK1/5/2011 1/13/2011 FAIL
DetailsCarl Westfall
The IBC plan review was started on January 6, 2011 and finished on January 13, 2011. Revised drawings were required. See the plan review report.
Routing - PUBLIC WORKS1/3/2011 1/5/2011 PASS
DetailsBeverly Mountain
Routing - PLANNING1/5/2011 1/5/2011 PASS
DetailsCody Riddle
Cody Riddle - Office in M-1D/ Office use previously approved.
Routing - Addressing1/4/2011 1/4/2011 PASS
DetailsApril Wing
Pending Assignment by JCB12/30/2010 1/3/2011 DONE
DetailsJason Blais
Application received 12/30/201012/30/2010 DONE
DetailsChristina Prado
Plans ACCEPTED BY PLAN TECH  12/30/2010 DONE
DetailsChristina Prado
Recd Pcfee & Taken To Pln CK  12/30/2010 DONE
DetailsChristina Prado