Permit Information
Permit NumberBLD11-00323
StatusFinaled
Name ST LUKES REG MED CNTR
Site Address 190 E BANNOCK ST
Project NameSLRMC
Customer Number 
ePlanReviewNo
Description
(ST. LUKE'S 1S BI-PLANE SPECIALS LAB) Remodel of a 2,950 sq. ft. area on the first floor of an existing hospital building per approved plans. This space will expand into previous part of exit corridor to stair enclosure serving lower levels but will not effect required egress path for other areas of hospital on 1st floor or from lower levels. Work to include select demolition to allow expansion & remodel of 2,950 sq. ft. within existing BI-PLANE SPECIALS LAB on 1st floor. To construct interior non-bearing walls to create the BI-PLANE room, control room, read room, clean and solied linen rooms, (3) private office's, waiting - reception - office and unisex accessible restroom; interior finishes, electrical, mechanical, plumbing, fire and alarm system modifications and a structural support platform on the roof for new HVAC unit and below the roof line to support the new overhead mounted equipment in BI-Plane room. NOTE: This building is fully fire sprinklered. Special Inspection is required as indicated on plans. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice8/23/20138/23/20138/29/2013 DONE
DetailsDave Hannah
old permit was finaled in 2011
BLD-Aging Inspection8/22/20138/22/20138/23/2013 PASS
DetailsDave Hannah
DOC - Permit Finaled8/23/20138/23/20138/23/2013PPASS
DetailsDave Hannah
BLD-Final3/21/20133/21/20133/21/2013APASS
DetailsDave Hannah
BLD-Aging Inspection3/20/20133/21/20133/21/2013APASS
DetailsDave Hannah
BLD-Final11/8/201111/9/201111/14/2011APASS
DetailsDave Hannah
Kelly Phone #: ###-####
FIRE-Final Inspection11/8/201111/8/201111/8/2011PPASS
DetailsForrest France
Fire life safety final approved.
BLD-Framing/Rough-in10/13/201110/13/201110/13/2011PPASS
DetailsDave Hannah
kelly - ceiling cover Phone #: ###-####
BLD-Framing/Rough-in9/27/20119/28/20119/29/2011APASS
DetailsDave Hannah
kelly Phone #: ###-####
BLD-Framing/Rough-in7/26/20117/28/20117/28/2011APART
DetailsDave Hannah
Kelly Phone #: ###-#### shaft ok to cover
BLD-Framing/Rough-in7/25/20117/26/20117/26/2011APART
DetailsDave Hannah
kelly Phone #: ###-#### ok to cover walls
FIRE-Sprinkler Rough-in6/15/20116/15/20116/15/2011PPART
DetailsForrest France
Okay to cover fire sprinkler work at three rooms as marked on plans including the office, reception and managers rooms.
BLD-Final6/10/20116/15/20116/15/2011APART
DetailsDave Hannah
Zach Phone #: ###-####This is a phased project ok to move in to phase one
BLD-Framing/Rough-in5/24/20115/25/20115/25/2011APART
DetailsDave Hannah
kelly Phone #: ###-#### ceiling grid phase one
BLD-Framing/Rough-in4/15/20114/18/20114/18/2011APART
DetailsDave Hannah
KELLY Phone #: ###-#### first phase ok to cover walls after other trades ok
Issue & PRINT to be Invoiced  3/31/2011 DONE
DetailsTisha Gallop
PLANS/APPL TAKEN TO FRONT DESK  3/29/2011 PASS
Inspection Record Card- Bld  3/29/2011 DONE
DetailsBarbara Stitt
Permit Ready to Issue  3/29/2011 DONE
DetailsBarbara Stitt
Telephone call  3/29/2011 DONE
DetailsBarbara Stitt
Left curtis a voice message that permit is ready & fees due on 3-29-11 @ 2:05pm
Plan assigned to (DRS)2/25/2011 3/29/2011 PASS
DetailsDan Stuart
Routing - PLAN CHECK3/23/2011 3/29/2011 PASS
DetailsDan Stuart
Resubmittals of 3/25/11 inserted into plans. Routing to permit desk to process for permit issuance.
Plan resubmittals received  3/25/2011 DONE
DetailsChristina Prado
Received one copy of transmittal and response letter; Received one copy of structural calcs; received two copies of plans G-003, A-102, A-104, A-203, A-601, S101, and S102; Routed to Dan Stuart for review
Routing - FIRE3/17/2011 3/23/2011 PASS
DetailsScott Arellano
Attached IFC comments to plans
1st review completed  3/23/2011 FAIL
Failed Plan Check
Routing - PLAN CHECK3/3/2011 3/17/2011 FAIL
DetailsDan Stuart
Copy of plan review report e-mailed to architect for response by resubmittal. Plans routing to fire code analyst for review.
Plan resubmittals requested  3/17/2011 DONE
Copy of plan review to Ton Zabal & Josh Howa.
Routing - PLUMBING3/1/2011 3/3/2011 PASS
DetailsBill VanDegrift
hopper sink and eyewash may require additional cross connection control
Routing - PUBLIC WORKS2/25/2011 3/1/2011 PASS
DetailsConnie Baumgartner
Routing PW Sewer Rating3/1/2011 3/1/2011 PASS
DetailsConnie Baumgartner
Routing - Addressing2/25/2011 2/25/2011 PASS
DetailsTerry Records
Pending Assignment by JCB2/24/2011 2/25/2011 DONE
DetailsJason Blais
Intake Approval  2/24/2011 FAIL
Missing architectural signature on plan sheet, completed certificate of value and the Project Start Up for special Inspection form.
Intake Approval  2/24/2011 PASS
4:30 pm returned with stamped & signed sheet and inserted into plans and provided certificate of value and Start Up For Special Inspection form.
Plans ACCEPTED BY PLAN TECH  2/24/2011 DONE
DetailsChristina Prado
Recd Pcfee & Taken To Pln CK  2/24/2011 DONE
DetailsChristina Prado
Intake Approval  2/22/2011 FAIL
Only one copy of application and plan sheets / specs. Sheet not stamped and signed, OSA not specified, no heating / cooling load calc analysis / summary for new unit, Project Start Up for special Inspection form and structural engineering design & calcs were not provided.
Plan Reviewer's activity  2/22/2011 DONE
Proposed by Josh ZGA to submit master spec book for SLRMC to have in our office and they would reference on each set of plans the specific specification sheets that would apply to project and we would use master spec to review. Any changes to standard specs would be submitted for inserting into spec master and would probably be updated on a yearly basis.
This could present a problem if someone else is reviewing plans and needs specs and would make a larger, bulkier document to circulate with plans for other agency review. Only the specs that are applicable to the project is all that would be needed, be easier to handle and route.
I reviewed this proposal by ZGZ / SLRMC with Jason Blais, Building Official. For now we only need the specifications that are applicable to the project being submitted, either in a separate book, incorporated into the plan sheets or a combination of both.

Josh also proposed the use of an electronic note on the plans were they are normally stamped, signed and dated by the design professionalsaying something like, "original stamped, signed and dated plans for this project are available at the design professionals office for review if needed."
Our application for projects that require the plans be prepared by a design professional licensed in the State of Idaho with signature and date the professionals license expires to allow verification of current licensing.
Discussed with Jason Blais. The plans need to be stamped and signed with license expiration date on the plans. They do not have to be a wete stamp. They can be copies of original stamped plan sheets.
Application received 2/22/2011