Permit Information
Permit NumberBLD11-00671
StatusFinaled
Name RAYMOND HANDLING CONCEPTS
Site Address 5957 W VANDAL WAY
Project NameMYGRANT GLASS - RACKING
Customer Number 
ePlanReviewNo
Description
(MYGRANT GLASS - RACKING) To install steel storage racking in an existing 33,490 sq. ft. warehouse portion of existing 39,502 sq. ft. tenant space per approved plans and structural engineering. Tenant approved in space under permit BLD11-00752. Work to include installation of steel storage racks 16' and 19' in height. Installation of steel storage racks shall be in accordance with the 2008 RMI Standard as referenced in the 2009 IBC, attached structrual engineering design calculations and details, and ESR-1917 for Hilti Kwik Bolt TZ anchors. NOTE: This building is fully fire sprinklered for area increase. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 6/4/20116/13/2011 DONE
DetailsChristina Prado
Faxed 6-13-11
First Notice5/10/20115/10/20115/25/2011 DONE
DetailsJim Storey
BLD-Final5/9/20115/10/20115/10/2011PPASS
DetailsJim Storey
Brad Phone #: ###-####
DOC - Permit Finaled5/10/20115/10/20115/10/2011PPASS
DetailsJim Storey
FIRE-Final Inspection5/9/20115/10/20115/10/2011APASS
DetailsTroy Cobbley
Life safety passed
BLD-Final5/3/20115/4/20115/4/2011APART
DetailsJim Storey
Joe Phone #: ###-#### pending fire cabnet on fire sign off/ final ok on bld.
FIRE-Final Inspection5/3/20115/3/20115/3/2011PPART
DetailsTroy Cobbley
Joe Phone #: ###-#### A temporary occupancy was given with Scott's permission until the hazardous material cabinet, which is on order, has arrived and been placed.
Telephone call  5/3/2011 DONE
I told Joe that the new letter provided by Greg Patrick at TVFP was acceptable. That the building would be OK for Class III commodities but not Class IV commodities. I also reminded him that the letter indicated that all flammable liquids would be in cabinets. The cabinets would be required to be on site prior to the inspection per Troy Cobbley request.
FIRE-Final Inspection5/2/20115/2/20115/2/2011PFAIL
DetailsTroy Cobbley
Column protection has not been provided per IFC chapter 23 and NFPA 13 6.1.4.1. The commodity has been classified as up to IV but the density will provide for a class III per the chapter 16 table.
Issue PAID IN FULL permit  4/21/2011 DONE
DetailsTisha Gallop
Inspection Record Card- Bld  4/20/2011 DONE
Permit Ready to Issue  4/20/2011 DONE
DetailsTisha Gallop
Telephone call  4/20/2011 DONE
DetailsTisha Gallop
called Joe Moulia and left vm permit is ready, fees and also that Occupancy permit Bld11-00752 is ready.
PLANS/APPL TAKEN TO FRONT DESK  4/19/2011 PASS
Routing - PLAN CHECK4/11/2011 4/19/2011 PASS
DetailsDan Stuart
Permit BLD11-00752 being issued to establish a certificate of occupancy for this new tenant.
Plan assigned to (DRS)4/7/2011 4/19/2011 PASS
DetailsDan Stuart
Telephone call  4/18/2011 DONE
Returned call to Bob, Structural Concepts Eng. 1-###-#### concerning Mygrant Glass Inc. BLD11-00671. Question on information for new storage racks have been satisfied. The only outstanding item before permit can be issued is obtaining a new cwertificate of occupancy for the new tenant. Need to determine if any changes made which would then be a tenant improvement app and plans for work to be done or if no change than a completed application to establish a certificate of occupancy with an existing floor plan layour and room use is needed to prepare a permit to determine requirements for issuing a new C.O.
1st review completed  4/11/2011 FAIL
Failed Plan Check
Routing - FIRE4/8/2011 4/11/2011 PASS
DetailsScott Arellano
Attached IFC comments to plans.
Plan resubmittals requested  4/8/2011 DONE
Resubmittal of completed Project Start Up For Special Inspection form required. Copy of plan review to applicant and engineer.
Plan Reviewer's activity  4/8/2011 DONE
Sent e-mail to applicant Joe Moulia with copy to Michael Mygrant for need to obtain a certificate of occupancy for new tenant. Referenced then to PDS on line Docs & forms to download and complete approriate application, checklist, cert of value, design professioanl of record, contractor license. etc. before the permit can be issued the tenant is required to obtain a certificate of occupancy.
Routing - PLAN CHECK4/7/2011 4/8/2011 FAIL
DetailsDan Stuart
Resubmittals required. copy of plan review e-mailed to Engineer Bob Sharif & applicant Joe Moulia. Plans routed to fire code analyst.
Pending Assignment by JCB4/6/2011 4/7/2011 DONE
DetailsJason Blais
Application received 4/6/20114/6/2011 DONE
DetailsTisha Gallop
Intake Approval  4/6/2011 PASS
OK to submit application.
Plans ACCEPTED BY PLAN TECH  4/6/2011 DONE
DetailsTisha Gallop
Recd Pcfee & Taken To Pln CK  4/6/2011 DONE
DetailsTisha Gallop