Permit Information
Permit NumberBLD11-02585
StatusFinaled
Name BAGLEY LTD CO
Site Address 5253 W KENDALL ST
Project NameTERRA FRESH
Customer Number 
ePlanReviewNo
Description
(TERRA FRESH) Remodel for a new 16,184 sq. ft. industrial tenant with existing office areas within an existing 2 story, 30,816 sq. ft. (24,202 sq. ft.- 1st; 3,614 sq. ft. covered dock, 1st; 3,000 sq. ft. 2nd level) building per approved plans. Work to include modification within existing portion of 16,184 sq. ft. to create a new 1,123 sq. ft. production / processing & 7,981 sq. ft. plastic pallet / tote storage area occupancy use and maintain the existing office area. NOTE: This building is NOT fire sprinklered at this time. There is copy of an Upgrade Agreement attached to this permit addressed to 5253 Kendall and to 5237 Kendall (Hickory Farms) to install a sprinkler system throughout the building per the approve agreement. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Agreement of Future work12/20/201112/16/20133/28/2014 DONE
DetailsDan Stuart
12/20/11 Upgrade Agreement to fire sprinkler this building attached to this case. To be completed in two years (12/16/13). If not a one year extension may be granted by the Building Official and Fire Marshal where a bond may be required to be posted.

Underground installed under FIR13-00453 10-15-13 ajs

Recieved email from Doug. Contract for system signed with Treasure Valley Fire Protection. submittal by end of month 10/15/13 ajs

Fire sprinkler plans submitted 11/6/13. FIR13-00620 11/18/13 ajs

1/30/14 Doug Bagley emailed status indicating final completion should be done by the end of February.

3/28/14 All work required under the Upgrade Agreement is completed. Copy of recorded Notice of Compliance is attached to this case. JCB
Plan Reviewer's activity  3/28/2014 DONE
DetailsJason Blais
All work required under the Upgrade Agreement is completed (see FIR13-00620 and FIR14-00015). A copy of the recorded Notice of Compliance is attached to this case.
First Notice 2/17/20123/1/2012 DONE
BLD-Final2/7/20122/7/20122/7/2012PPASS
DetailsTom Arcoraci
JR Phone #: ###-####
Override - Parcel Holds2/7/20121/1/19002/7/2012  
not to do with this project
Override - Parcel Holds  2/7/2012  
Permanent Occupancy  2/7/2012 DONE
DetailsBarbara Stitt
FIRE-Final Inspection2/3/20122/3/20122/3/2012PPASS
DetailsTroy Cobbley
Life safety passed
FIRE-Conference1/20/20121/20/20121/20/2012PDONE
DetailsTroy Cobbley
Jr and I went over life safety requirements which include the possible demolishion of an existing fire alarm system or making sure it is functional. Door hardware needs to be compliant as well as repairing/adding exit signs and emergency lights and fire extinguishers.
BLD-Conference1/4/20121/4/20121/4/2012ADONE
DetailsTom Arcoraci
dennis Phone #: ###-####
BLD-Conference1/3/20121/3/20121/4/2012PDEFR
DetailsDave Hannah
dennis Phone #: ###-####
Routing - FIRE12/20/2011 12/21/2011 PASS
DetailsScott Arellano
Attached IFC comments to plans
Routing - PLAN CHECK12/21/2011 12/21/2011 PASS
DetailsDan Stuart
To permit desk to issue.
PLANS/APPL TAKEN TO FRONT DESK  12/21/2011 PASS
Print Occupancy Form  12/21/2011 DONE
Telephone call  12/21/2011 DONE
DetailsChristina Prado
Called and gave Pat fees due and advised of GC/RCE requirements
Permit Ready to Issue  12/21/2011 DONE
DetailsChristina Prado
Issue PAID IN FULL permit  12/21/2011 DONE
DetailsBarbara Stitt
Plan assigned to (DRS)10/27/2011 12/21/2011 PASS
DetailsDan Stuart
Routing - PLAN CHECK12/5/2011 12/20/2011 PEND
DetailsDan Stuart
Upgrade Agreement for sprinkling of building is signed and to be recorded. Plans routing to fire code anlayst for re-review.
Plan Reviewer's activity  12/16/2011 DONE
Copy of proposed upgrade agreement for sprinking the building within the next 2 years from date of approval of alternate will be attached to this plan.
Plan resubmittals received  12/7/2011 DONE
DetailsTisha Gallop
received response and two copies of plan sheets T1.0, A1.1, A1.2, A1.3, A1.4; taken to Dan Stuart.
1st review completed  12/5/2011 FAIL
Failed Plan Check, Fire
Routing - FIRE11/30/2011 12/5/2011 FAIL
DetailsScott Arellano
Faxed and emailed resubmittal items to architect.
Plan resubmittals requested  11/30/2011 DONE
Copy of plan review items e-mailed to architect for his response.
Routing - PLAN CHECK11/3/2011 11/30/2011 FAIL
DetailsDan Stuart
Resubmittals required. Plans routed to fire code analyst for review.
Routing - PLUMBING11/2/2011 11/3/2011 PASS
DetailsBill VanDegrift
Plumbing for mixing tanks? may require additional backflow protection per plans and 2003 upc.
Routing - PUBLIC WORKS  11/2/2011 PASS
Routing PW Environmental10/31/2011 10/31/2011 PASS
DetailsWalt Baumgartner
Facility operations must comply w/ Bench Sewer District pretreatment requirements for any non domestic discharge to sanitary sewer including accidental spill protection measures. Contact Rick at Bench SD ###-####
Routing - Addressing10/27/2011 10/28/2011 PASS
DetailsTerry Records
Pending Assignment by JCB10/25/2011 10/27/2011 DONE
DetailsJason Blais
Application received 10/25/201110/25/2011 DONE
DetailsBarbara Stitt
Intake Approval  10/25/2011 PASS
Recd Pcfee & Taken To Pln CK  10/25/2011 DONE
DetailsBarbara Stitt
Plans ACCEPTED BY PLAN TECH  10/25/2011 DONE
DetailsBarbara Stitt