Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberBLD11-02821
StatusFinaled
Name JAYO CONSTRUCTION
Site Address 2315 N PLEASANT HILL WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Permit for the construction of a new 2,876 sq. ft., two story (first story 1,983 sq. ft., second story 893 sq. ft.) single family dwelling with 4 bedrooms, 3 1/2 bathrooms, approximately 256 sq. ft. of covered patio/porch and a 994 sq. ft. attached garage per the approved plans, plan review report and any notations. This structure is located in WUI zone A and requires a class A roofing material, noncombustible exterior siding material and one hour fire rated soffits. A-1 zoning and setbacks per palnning. CDM
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/31/20128/2/20128/2/2012ADONE
DetailsTony Young
Phone #: ###-#### >> Inspection requested via web by SHANE JAYO
DOC - Permit Finaled8/2/20128/2/20128/2/2012PPASS
DetailsTony Young
c of o issued
BLD-Final7/23/20127/24/20128/1/2012APASS
DetailsTony Young
micah Phone #: ###-####
BLD-Grading Inspection7/30/20127/30/20127/30/2012ADONE
DetailsTerry Records
Final grading and drainage approved
BLD-Final7/20/20127/23/20127/23/2012APART
DetailsTony Young
Phone #: ###-#### >> Inspection requested via web by SHANE JAYO,, all good now,, just need hillside with public works finaled
DOC - Permit Finaled7/23/20127/23/20127/23/2012PNR
DetailsTony Young
done
CHANGE STATUS TO (ISS)  7/23/2012 DONE
DetailsTisha Gallop
permit doc-finaled by mistake per insp 415
BLD-Final7/20/20127/20/20127/20/2012PNR
DetailsTony Young
Phone #: ###-#### >> Inspection requested via web by SHANE JAYO
BLD-Energy code compliance4/27/20124/30/20124/30/2012APASS
DetailsTony Young
>> Inspection requested via web by SHANE JAYO
BLD-Wall Bracing4/25/20124/26/20124/26/2012APASS
DetailsJim Sly
Phone #: ###-#### >> Inspection requested via web by SHANE JAYO
BLD-Framing/Rough-in4/24/20124/25/20124/25/2012APART
DetailsTony Young
Phone #: ###-#### >> Inspection requested via web by SHANE JAYO,, need to nail shear per plan,, interior ok to insulate,, Shane has minor correction notice
BLD-Foundation2/15/20122/16/20122/16/2012APART
DetailsTony Young
CHRIS Phone #: ###-####,, work in progress
BLD-Footing2/14/20122/15/20122/16/2012APASS
DetailsTony Young
CHRIS Phone #: ###-####
PubWorks Subgrade Approval2/10/20122/10/20122/10/2012 DONE
DetailsTerry Records
Footing subgrade approved by the geotechnical engineer
Issue PAID IN FULL permit  1/31/2012 DONE
DetailsBarbara Stitt
Plan assigned to (CDM) 11/22/201112/23/2011 PASS
DetailsCarl D Madsen
Routing - MECHANICAL12/23/2011 12/23/2011 PASS
DetailsTroy James
Routing - PLAN CHECK12/23/2011 12/23/2011 PASS
DetailsCarl D Madsen
PLANS/APPL TAKEN TO FRONT DESK  12/23/2011  
Inspection Record Card- Bld  12/23/2011 DONE
Permit Ready to Issue  12/23/2011 DONE
DetailsTisha Gallop
Telephone call  12/23/2011 DONE
DetailsTisha Gallop
called Shane Jayo and left vm permit is ready and fees.
Routing - PLAN CHECK11/29/2011 12/21/2011 PASS
DetailsCarl D Madsen
Case Summary (BLD)  12/21/2011 DONE
1st review completed  12/21/2011 FAIL
Failed pending Planning and Mechanical 12-21-11 CDM
Routing - PLANNING12/21/2011 12/21/2011 PASS
DetailsDavid Moser
Routing PW Grading-Hillside12/14/2011 12/14/2011 PASS
DetailsTerry Records
Route to Impact Fee Review11/22/201111/28/201112/5/2011 PASS
DetailsCindy M. Gould
Plan resubmittals received  12/5/2011  
Received 3 copies of sheet C-1.0, S-1.0, and 2 copies of sheet S-1.0 reduced to 8 1/2x11 and taken to put with the plans//BAS
Routing - FIRE11/28/2011 11/29/2011 PASS
DetailsScott Arellano
No AS requirement.
Routing - Erosion and Sediment11/23/2011 11/28/2011 PASS
DetailsClint A Smith
ESC11-00841 plan approved with conditions attachedd to the permit.
Routing PW Grading-Hillside  11/23/2011 FAIL
DetailsTerry Records
Grading plan needs revisions
Routing - MECHANICAL11/23/2011 11/23/2011 FAIL
DetailsTroy James
sent corrections to AJ
Routing - PLANNING11/23/2011 11/23/2011 FAIL
DetailsDavid Moser
Covered back deck is within a drainage easement as per plat. Need to move building forward a few feet to step the covered deck posts out of easement and provide a new site plan. Called and left message with applicant on 11-23-11.
Routing - Addressing11/22/2011 11/23/2011 PASS
DetailsTerry Records
Routing - PUBLIC WORKS11/23/2011 11/23/2011 PASS
DetailsConnie Baumgartner
Plans ACCEPTED BY PLAN TECH  11/22/2011 DONE
DetailsChristina Prado
Intake Approval  11/22/2011 PASS
DetailsChristina Prado
Recd Pcfee & Taken To Pln CK  11/22/2011 DONE
DetailsChristina Prado
Application received 11/22/2011