Permit Information
Permit NumberBLD11-02834
StatusFinaled
Name BLACK BEAR DINER
Site Address 1731 S ENTERTAINMENT AVE
Project NameBLACK BEAR DINER
Customer Number 
ePlanReviewNo
Description
(BLACK BEAR DINER) (DRH11-00256) This building has a fire sprinkler system that is used for fire area. To remodel an existing 6,549 square foot restaurant building for a new restaurant tenant. Work is to include interior nonbearing walls, exterior windows, dining booths, interior tin roofing, interior log columns and log trim, interior windows, interior doors, two grease hoods, new kitchen equipment, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 10/4/20129/24/2012 DONE
Third Notice 8/29/20129/20/2012 DONE
mailed to teanants at project address; not sure who was GC, Rob Brady (from Midvalue, Utah) is not registered with IBOL, the RCT listed on the permit and the Idaho GC form is signed by Ryan Partridge (company name RW Partridge), mailing address from Firth, Idaho, but his name is no where else in the permit or on any inspections.
Second Notice 8/11/20128/24/2012 DONE
First Notice 7/27/20128/1/2012 DONE
Permanent Occupancy  7/17/2012 DONE
DetailsChristina Prado
CHANGE STATUS TO (ISS)  7/13/2012  
This permit was finaled by mistake it still needed to have mechanical go out and check kitchen equipment Ref mis12-00196///dld
BLD-Final7/11/20127/12/20127/12/2012PPASS
DetailsMike Jordan
Steven Phone #: ###-####. Will be ok for perm occ. once zoning signs off.
FIRE-Final Inspection7/11/20127/12/20127/12/2012APASS
DetailsTroy Cobbley
Life safety passed
Zoning Approval7/12/20127/12/20127/12/2012 DONE
DetailsAndrea Tuning
FIRE-Final Inspection7/11/20127/11/20127/11/2012PPEND
DetailsForrest France
Meeting  7/11/2012 DONE
DetailsScott Arellano
The Fire Marshal has approved the request for Temporary Occupancy.
FIRE-Conference7/10/20127/10/20127/10/2012PDONE
DetailsTroy Cobbley
Life safety will be ok to final when the project related fire alarm permit is finaled.
BLD-Conference5/15/20125/16/20125/16/2012ADONE
DetailsTroy Cobbley
The general contractor, the owner Steven Wong and I discussed sprinkler spacing issues. I deferred him to a qualified sprinkler contractor to perform a walk through to address potential obstruction issues. We also discussed fire alarm notification device placement and hood suppression system interconnections. I also went over new exit sign/emergency light placement and door hardware requirements.
BLD-Framing/Rough-in5/15/20125/16/20125/16/2012APASS
DetailsMike Jordan
Rob Phone #: ###-####. Interior wood stud framed walls ok.
Issue PAID IN FULL permit  2/3/2012 DONE
DetailsChristina Prado
Telephone call  1/26/2012 DONE
DetailsChristina Prado
Left message for Adam Ford giving fees due and advising permit is ready to be picked up
Permit Ready to Issue  1/26/2012 DONE
DetailsChristina Prado
PLANS/APPL TAKEN TO FRONT DESK  1/25/2012 DONE
Print Occupancy Form  1/25/2012 DONE
Plan assigned to (CJW)12/7/2011 1/25/2012 PASS
DetailsCarl Westfall
BLACK BEAR DINER (20 days - January 4 due to 2 holidays)
Routing - PLAN CHECK12/30/2011 1/25/2012 PASS
DetailsCarl Westfall
Drawings approved after resubmittal review.
Plan resubmittals received  1/23/2012 DONE
DetailsChristina Prado
Received one copy of transmittal letter; responce letter; two copies of plans marked G001, G002, A101, A102, A401 & E2.1. Plans given to Carl Westfall for further review
Route to Impact Fee Review12/30/20111/4/20121/6/2012 PASS
DetailsCindy M. Gould
Tenant improvement no impact fees
Routing - FIRE12/30/201112/30/201112/30/2011 PASS
DetailsScott Arellano
Attached IFC comments to plans
1st review completed  12/30/2011 FAIL
Failed Plan Check
Routing - PLAN CHECK12/13/2011 12/30/2011 FAIL
DetailsCarl Westfall
The IBC plan review was started on Dec 29 and was finished the next day. Revised drawings were required. See the plan review report.
Routing - Design Review12/9/2011 12/13/2011 PASS
DetailsAndrea Tuning
Andrea Tuning - DRH11-00256
Routing - PLUMBING12/8/2011 12/9/2011 PASS
DetailsBill VanDegrift
Per plans and 2003 UPC.
Routing - PUBLIC WORKS12/8/2011 12/8/2011 PASS
DetailsConnie Baumgartner
Routing PW Sewer Rating12/8/2011 12/8/2011 PASS
DetailsConnie Baumgartner
Routing PW Environmental12/8/2011 12/8/2011 PASS
DetailsWalt Baumgartner
All kitchen dish area and food prep fixtures must connect to the existing grease interceptor. Facility subject to sewer pretreatment compliance inspection post opening of operations.
Routing - Addressing12/7/2011 12/7/2011 PASS
DetailsTerry Records
Pending Assignment by JCB12/6/2011 12/7/2011 DONE
DetailsJason Blais
Recd Pcfee & Taken To Pln CK  12/7/2011 DONE
DetailsBarbara Stitt
Application received 11/23/201112/6/2011 DONE
DetailsBarbara Stitt
Intake Approval  12/6/2011 PASS
Details
Plans ACCEPTED BY PLAN TECH  12/6/2011 DONE
DetailsBarbara Stitt
Intake Approval  11/23/2011 FAIL
DetailsSam Zahorka
Refer to circled items on checklist attached to this case. SRZ