Permit Information
Permit NumberBLD11-03003
StatusFinaled
Name ROBERT GOEBEL GENERAL CONTRACTOR IN
Site Address 534 N MILWAUKEE ST
Project NameNORDSTROM RACK - RACKING
Customer Number 
ePlanReviewNo
Description
(NORDSTROM RACK - RACKING) - To construct steel storage racking/shelving within an existing retail building (BLD11-01395) to be used for stock shelving per approved plans and structural engineering. SPECIAL INSPECTIONS ARE REQUIRED. Work to include: To install 6,398 square feet total area of racking/shelving (including aisles). Each unit will be bolted to the floor, and have more than 36" isles between rows. The design, testing and utilization of industrial steel storage racks shall be in accordance with the RMI/ANSI MH 16.1. A Letter of Completion is to be issued when done. The existing envelope is not being affected by this permit. NOTE: This building is fully fire sprinklered for area increase. Any alterations or modifications to the sprinkler system shall be per NFPA 13 as regulated by the fire department. EACH RACKING SYSTEM SHALL HAVE A PLAQUE LOCATED AT EACH RACKING SYSTEM STATING THE MAXIMUM WEIGHT TO BE STORED ON THAT PERTICULAR RACKING SYSTEM PER THE ENGINEERS CRITERIA STATED ON THE PLANS FOR EACH RACKING SYSTEM. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 4/8/20124/16/2012 DONE
DetailsChristina Prado
complete 4-10-12
First Notice3/15/20123/26/20123/29/2012 DONE
DetailsMike Jordan
faxed 3-29-2012
BLD-Final3/14/20123/15/20123/15/2012APASS
DetailsMike Jordan
Stu Phone #: ###-####
DOC - Permit Finaled3/15/20123/15/20123/15/2012PPASS
DetailsMike Jordan
FIRE-Final Inspection3/13/20123/14/20123/14/2012APASS
DetailsTroy Cobbley
life safety passed. wire shelving is provided
FIRE-Final Inspection3/12/20123/13/20123/13/2012PFAIL
DetailsTroy Cobbley
Life safety will be ok to final when the Demo/shell permit has been inspected/finaled. I will be meeting Joe with J and B Construction in the morning.
FIRE-Conference3/6/20123/7/20123/7/2012ADONE
DetailsTroy Cobbley
I went over life safety requirements with general contractor. There is an issue with solid shelving on the large storage racks. Also per Tim Frost racking was not addressed with the sprinkler plans but what I described to him over the phone he was ok with as long as the storage did not exceed 12' in height.
Issue PAID IN FULL permit  1/9/2012 DONE
DetailsTisha Gallop
PLANS/APPL TAKEN TO FRONT DESK  1/6/2012 DONE
DetailsSam Zahorka
Case Summary (BLD)  1/6/2012 DONE
DetailsSam Zahorka
Inspection Record Card- Bld  1/6/2012 DONE
Telephone call  1/6/2012 DONE
DetailsChristina Prado
Called and gave Steven fees due
Permit Ready to Issue  1/6/2012 DONE
DetailsChristina Prado
Plan assigned to (SRZ)12/22/2011 1/6/2012 PASS
DetailsSam Zahorka
Level 2 TI (Racking)
1st review completed.
Plan resubmittals received  1/5/2012 DONE
DetailsTisha Gallop
received one copy of Statement of Special Inspections; taken to Sam Zahorka.
Telephone call  1/3/2012 DONE
DetailsSam Zahorka
Spoke with the engineer and emailed Statement of Special Inspection form. He stated he would fill out and email back to me.
Routing - PLAN CHECK12/28/2011 12/29/2011 PASS
DetailsSam Zahorka
Pending the submittal of the Statement of Special Inspection #310 for Special Inspection.
Routing - PLAN CHECK12/22/2011 12/28/2011 PASS
DetailsSam Zahorka
Routing - FIRE12/28/2011 12/28/2011 PASS
DetailsScott Arellano
Total High Piled Storage (HPS) is less than 500 square feet. No separate HPS comments attached.
1st review completed  12/28/2011 PASS
Application received 12/22/201112/22/2011 DONE
DetailsBarbara Stitt
Intake Approval  12/22/2011 PASS
Plans ACCEPTED BY PLAN TECH  12/22/2011 DONE
DetailsTisha Gallop
Recd Pcfee & Taken To Pln CK  12/22/2011 DONE
DetailsTisha Gallop
Pending Assignment by JCB12/22/2011 12/22/2011 DONE
DetailsJason Blais