Permit Information
Permit NumberBLD12-00107
StatusFinaled
Name SPECIALTY INSTALLATIONS INC
Site Address 760 W MAIN ST
Project NameTaphouse
Customer Number 
ePlanReviewNo
Description
(TAP HOUSE – Capitol Terrace Bldg) Permit is remodel an existing 2,520 sq ft restaurant tenant space into a new restaurant tenant space. Approval contingent upon adhering to the approved plans on file. Work to include: reinstallation of a class I hood (in old class one hood location), new equipment, new furnishing, [plumbing, mechanical, and electrical modifications], and interior finishes in compliance with Ch 8 of the 2009 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. Note: permits are required thorough the Fire Dept. based on new hood installation. **TLW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 5/26/20125/17/2012 DONE
Third Notice 5/22/20125/17/2012 DONE
First Notice 4/19/20125/16/2012 DONE
Permanent Occupancy  4/9/2012 DONE
DetailsChristina Prado
BLD-Final4/5/20124/5/20124/5/2012PPASS
DetailsDave Hannah
BLD-Conference4/5/20124/5/20124/5/2012PPASS
DetailsDave Hannah
bian Phone #: ###-#### please call 20 min before going out
FIRE-Final Inspection4/5/20124/5/20124/5/2012PPASS
DetailsForrest France
Previous correction items completed. Fire life safety finaled.
FIRE-Conference4/4/20124/4/20124/5/2012PDONE
DetailsForrest France
On site conference with tenant regarding fire life safety conditions prior to occupancy.
Telephone call  1/31/2012 DONE
DetailsTisha Gallop
Called Brian with revised fees due, also told him still need GC & form and plumbing value.
Issue PAID IN FULL permit  1/31/2012 DONE
DetailsChristina Prado
Plan assigned to (TLW)1/20/2012 1/26/2012 PASS
DetailsTim L. Woodard
Routing - PLAN CHECK1/25/2012 1/26/2012 PASS
DetailsTim L. Woodard
Approved with comments included in Plan Review Report attached. TLW
1st review completed  1/26/2012 DONE
DetailsTim L. Woodard
PLANS/APPL TAKEN TO FRONT DESK  1/26/2012 DONE
DetailsTim L. Woodard
Case Summary (BLD)  1/26/2012 DONE
DetailsTim L. Woodard
Case Summary (BLD)  1/26/2012 DONE
DetailsTim L. Woodard
Print Occupancy Form  1/26/2012 DONE
Telephone call  1/26/2012 DONE
DetailsChristina Prado
left message for Brian giving fees due and advising GC/RCE is required prior to issuance
Permit Ready to Issue  1/26/2012 DONE
DetailsChristina Prado
Routing - PLAN CHECK1/25/2012 1/25/2012 PEND
DetailsTim L. Woodard
routed to plumbing
Routing - PUBLIC WORKS1/20/2012 1/25/2012 PASS
DetailsConnie Baumgartner
Routing - PLUMBING1/25/2012 1/25/2012 PASS
DetailsDaryl Spivey
Existing equipment may require additional backflow protection.
Per plans and 2003 UPC.
Routing PW Environmental1/24/2012 1/24/2012 PASS
DetailsWalt Baumgartner
Existing in floor grease trap will require routine, weekly maintenance. This facility operation subject to pretreatment compliance inspections. Upgrade to grease abatement can be required at future date if current equipment proves inadequate.
Routing PW Sewer Rating1/24/2012 1/24/2012 PASS
DetailsConnie Baumgartner
Routing - Addressing1/23/2012 1/23/2012 PASS
DetailsApril Wing
Application received 1/19/20121/20/2012 DONE
DetailsTisha Gallop
Plans ACCEPTED BY PLAN TECH  1/20/2012 DONE
DetailsTisha Gallop
Recd Pcfee & Taken To Pln CK  1/20/2012 DONE
DetailsTisha Gallop
(F) Reprint permit  1/20/2012 DONE
DetailsTisha Gallop