Permit Information
Permit NumberBLD12-00282
StatusFinaled
Name ALPINE CONSTRUCTION INC
Site Address 1253 N COLE RD
Project NamePEACE IN JESUS LUTHERAN CHURCH
Customer Number 
ePlanReviewYes
Description
(PEACE IN JESUS LUTHERAN CHURCH) (CUP11-00073 and CZC11-00258) The fire sprinkler system is used for building area increase and for fire area occupant load. To convert an existing 10,515 square foot building to a church. Work is to include interior nonbearing walls, furred gypsum board ceiling, new entry canopy (concrete footings, concrete piers, wood columns, wood beams, wood trusses, and wood structural sheathing), a platform, millwork, and finishes. All new work is required to be accessible to the disabled. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 9/24/20129/24/2012 DONE
DetailsChristina Prado
Done 9-24-12
Second Notice 9/2/20129/19/2012 DONE
DetailsChristina Prado
faxed 9-19
First Notice 8/16/20128/23/2012 DONE
DetailsChristina Prado
faxed
BLD-Final8/3/20128/6/20128/6/2012APASS
DetailsMike Jordan
Garrett Phone #: ###-####. ok for perm occ. map has been posted, emergency lighting at main enterance repaired.
Permanent Occupancy  8/6/2012 DONE
DetailsChristina Prado
FIRE-Final Inspection8/3/20128/3/20128/3/2012PPASS
DetailsTroy Cobbley
Life safety passed. The exit sign/emergency light at the main entrance was non-functional but is to be repaired and shown to function to the building inspector.
FIRE-Final Inspection8/1/20128/3/20128/3/2012AFAIL
DetailsTroy Cobbley
Provide completion of the project related fire alarm permit and provide the three missing exit discharge lights.
BLD-Final8/1/20128/3/20128/3/2012PCANC
DetailsMike Jordan
Garrett Phone #: ###-####
Zoning Approval7/10/20127/10/20127/10/2012 PASS
DetailsJosh Wilson
BLD-Other7/2/20127/3/20127/3/2012APASS
DetailsDave Hannah
above grid for cover//Garrett Phone #: ###-####
BLD-Framing/Rough-in6/5/20126/6/20126/6/2012APASS
DetailsMike Jordan
garrett Phone #: ###-####. Canopy framing ok. Also recieved RFI for new header deatil at new opening. All work done per approved plans and RFI.
BLD-Framing/Rough-in5/17/20125/18/20125/18/2012APART
DetailsMike Jordan
Garrett Phone #: ###-####. Ok to sheet rock interior steel stud walls and hardlid areas only. RFI required for new header from design professional, not installed per approved plans. Also spoke to contractor regarding stage ramp and new door from audio room.
BLD-Framing/Rough-in4/30/20124/30/20124/30/2012PNR
DetailsMike Jordan
Garrett Phone #: ###-####
BLD-Footing4/30/20124/30/20124/30/2012PPASS
DetailsMike Jordan
canopy footing -- Garrett Phone #: ###-####
OVERRIDE  4/9/2012  
Issue PAID IN FULL permit  4/9/2012 DONE
DetailsChristina Prado
Print Occupancy Form  4/9/2012 DONE
DetailsChristina Prado
Permit Ready to Issue  4/9/2012 DONE
DetailsChristina Prado
Plan assigned to (CJW)2/16/20122/16/20124/6/2012 PASS
DetailsCarl Westfall
PEACE IN JESUS LUTHERAN CHURCH (20 days - Mar 13) ePlanReview case
Routing - PLAN CHECK4/4/2012 4/6/2012 PASS
DetailsCarl Westfall
Completed the resubmittal review. Drawings approved.
PLANS/APPL TAKEN TO FRONT DESK  4/6/2012 DONE
Plan resubmittals received  4/4/2012  
Routing - FIRE3/27/2012 3/29/2012 PASS
DetailsScott Arellano
Attached IFC comments to plans
Routing - Erosion and Sediment3/27/2012 3/28/2012 DONE
DetailsClint A Smith
transfer red lines
Routing - PLAN CHECK3/22/2012 3/27/2012 FAIL
DetailsCarl Westfall
Plan resubmittals received  3/22/2012 DONE
Route to Impact Fee Review3/8/20123/13/20123/9/2012 PASS
DetailsCindy M. Gould
New area is for entry way canopy it is not enclosed, no impact fees.
Routing - PLAN CHECK2/16/2012 3/8/2012 FAIL
DetailsCarl Westfall
The IBC plan review was started on Feb 24 and finished on Mar 8. Revised drawings were required. See the plan review report. Because of multiple plan intakes the 1st review of this project was delayed.
1st review completed  3/8/2012 DONE
Routing - FIRE2/16/2012 2/21/2012 PASS
DetailsScott Arellano
Routing PW Sewer Rating2/16/2012 2/21/2012 PASS
DetailsConnie Baumgartner
Routing - Erosion and Sediment2/16/2012 2/20/2012 PASS
DetailsClint A Smith
ESC12-00114 plan waiver approved with conditions attached tohe permit.
Routing - Addressing2/16/2012 2/17/2012 PASS
DetailsApril Wing
Routing - PUBLIC WORKS2/16/2012 2/16/2012 PASS
DetailsBeverly Mountain
Routing - Design Review2/16/2012 2/16/2012 PASS
DetailsJosh Wilson
Josh Wilson - CZC11-00258
Routing - PLANNING2/16/2012 2/16/2012 PASS
DetailsSue Cummings
Sue Cummings - CUP11-00073
Routing - PLUMBING2/16/2012 2/16/2012 PASS
DetailsBill VanDegrift
1. Ice makers may require backflow device.
Per plans and 2003 UPC.
Plan Reviewer's activity  2/16/2012 DONE
DetailsJason Blais
Emailed architect rep to contact ACHD for evaluation of any impact fees due and if an inspection is required. Written verification from ACHD will need to be provided to our Permit Counter prior to the building permit being issued.
Intake Approval  2/16/2012 PASS
DetailsJason Blais
John Menard approved intake on 2/15/12. Plan Review Fees paid on 2/16/12.
Intake Approval  2/15/2012 FAIL
DetailsJohn Menard
Please submit the following documents:
1. Please upload a completed ESC Application #701.
2. Please upload the referenced structural plan sheets.
Application received  2/13/2012 DONE
Application submitted via PDS Online on Feb 13 2012 3:52PM