Permit Information
Permit NumberBLD12-00730
StatusExpired
Name HANSEN-RICE INC
Site Address 4175 S BROADWAY AVE
Project NameTRAVEL CENTERS OF AMERICA
Customer Number 
ePlanReviewNo
Description
(TRAVEL CENTERS OF AMERICA - RACKING) Install new steel storage racking for tire storage exceeding 8' in height per structural engineering and approved plans. Work to include: Install 364 square feet (155'-9" X 28") of racking including aisles per engineering, attached plan review report, and the structural inspectors final approval. Hilti Kwik Bolt TZ anchors (ESR-1917) are called out to anchor racks. SPECIAL INSPECTIONS ARE REQUIRED. The design, testing and utilization of industrial steel storage racks shall be in accordance with the RMI/ANSI MH 16.1. A Letter of Completion is to be issued when done. The existing envelope is not being affected by this permit. "This building will have an approved Fire Alarm system installed under a seoarate permit. Any alterations or modifications to the buildings Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 72 as regulated by the Boise Fire Department." EACH RACKING SYSTEM SHALL HAVE A PLAQUE LOCATED AT EACH RACKING SYSTEM STATING THE MAXIMUM WEIGHT TO BE STORED ON THAT PERTICULAR RACKING SYSTEM PER THE ENGINEERS CRITERIA STATED ON THE PLANS FOR EACH RACKING SYSTEM. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Expired4/25/20194/25/20194/25/2019PPASS
DetailsJim Storey
Telephone call  12/28/2015 DONE
left a message about getting a building final inspection scheduled
FIRE-Final Inspection5/12/20145/12/20145/12/2014APASS
DetailsForrest France
Fire life safety finaled.
FIRE-Final Inspection6/26/20126/26/20126/26/2012PPEND
DetailsForrest France
Pending fire alarm permit final.
FIRE-Final Inspection5/22/20125/22/20125/22/2012PPART
DetailsForrest France
Racking final is contingent upon project related fire alarm work per permit documents.
BLD-Final5/22/20125/22/20125/22/2012PCANC
DetailsJim Storey
Tony Phone #: ###-####
BLD-Final4/23/20124/24/20124/24/2012APART
DetailsJim Storey
tony Phone #: ###-#### need to lable beam loads
Issue PAID IN FULL permit  4/19/2012 DONE
DetailsChristina Prado
Plan assigned to (SRZ)4/6/20124/6/20124/17/2012 PASS
DetailsSam Zahorka
Routing - FIRE4/16/2012 4/17/2012 PASS
DetailsTim Frost
See fire code plan review for BLD12-00508 for comments
1st review completed  4/17/2012 PASS
Pass
Routing - PLAN CHECK4/17/2012 4/17/2012 PASS
DetailsScott Arellano
PLANS/APPL TAKEN TO FRONT DESK  4/17/2012 DONE
DetailsSam Zahorka
Inspection Record Card- Bld  4/17/2012 DONE
Telephone call  4/17/2012 DONE
DetailsChristina Prado
Called Hansen Rice and gave fees due
Permit Ready to Issue  4/17/2012 DONE
DetailsChristina Prado
Case Summary (BLD)  4/16/2012 DONE
DetailsSam Zahorka
Routing - PLAN CHECK4/6/2012 4/16/2012 PASS
DetailsSam Zahorka
Pending Assignment by JCB4/5/2012 4/6/2012 DONE
DetailsJason Blais
Application received 4/4/20124/5/2012 DONE
DetailsChristina Prado
Plans ACCEPTED BY PLAN TECH  4/5/2012 DONE
DetailsChristina Prado
Intake Approval  4/5/2012 PASS
DetailsTim L. Woodard
Recd Pcfee & Taken To Pln CK  4/5/2012 DONE
DetailsChristina Prado