BLD-Final | 11/21/2012 | 11/23/2012 | 11/23/2012 | A | PASS |
Tom Arcoraci
|
|
|
Ted Phone #: ###-####
|
DOC - Permit Finaled | 11/23/2012 | 11/23/2012 | 11/23/2012 | P | PASS |
Tom Arcoraci
|
|
|
|
BLD-Energy code compliance | 9/21/2012 | 9/24/2012 | 9/24/2012 | A | PASS |
Mike Jordan
|
|
|
Alan Phone #: ###-####
|
BLD-Framing/Rough-in | 9/19/2012 | 9/20/2012 | 9/20/2012 | A | PASS |
Mike Jordan
|
|
|
alan Phone #: ###-####. All framing issues have bee resolved. Item #1 on correction notice not completed, fireblostop at top plates in garage. Will check on energy code inspection.
|
BLD-Wall Bracing | 9/20/2012 | 9/20/2012 | 9/20/2012 | A | PASS |
Mike Jordan
|
|
|
alan Phone #: ###-####
|
BLD-Framing/Rough-in | 9/18/2012 | 9/19/2012 | 9/19/2012 | A | FAIL |
Mike Jordan
|
|
|
Alan Phone #: ###-####. Firestop all top plates at tall wall, south wall in garage. Complete lateral bracing on trusses (E trusses) See engineering. See approved plan for all areas that require blocking and stapling for brace wall panel lines. Provide strap at joint 8 for BG1 3 ply truss. Provide adiitional 2x6 studs at H1 hip truss under joint 7. Also provide bearing at joint 21. Correction notice was posted.
|
Plan resubmittals received | | | 9/14/2012 | | DONE |
|
|
|
new acca report
|
Routing - MECHANICAL | 9/14/2012 | | 9/14/2012 | | PASS |
Troy James
|
|
|
resubmitted acca report
|
BLD-Foundation | 8/2/2012 | 8/3/2012 | 8/3/2012 | A | PART |
Mike Jordan
|
|
|
Phone #: 6951097 >> Inspection requested via mobile web by adam
|
BLD-Footing | 8/2/2012 | 8/2/2012 | 8/2/2012 | A | PASS |
Tom Arcoraci
|
|
|
Phone #: 6951097 >> Inspection requested via mobile web by adam
|
Plan assigned to (CDM) | 7/10/2012 | 7/10/2012 | 7/24/2012 | | PASS |
Carl D Madsen
|
|
|
|
Routing - PLAN CHECK | 7/19/2012 | | 7/24/2012 | | PASS |
Carl D Madsen
|
|
|
|
1st review completed | | | 7/24/2012 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 7/24/2012 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/24/2012 | | |
|
|
|
|
Inspection Record Card- Bld | | | 7/24/2012 | | DONE |
|
|
|
|
Telephone call | | | 7/24/2012 | | DONE |
Christina Prado
|
|
|
called and left message with tiffany giving fees due
|
Permit Ready to Issue | | | 7/24/2012 | | DONE |
Christina Prado
|
|
|
|
Issue PAID IN FULL permit | | | 7/24/2012 | | DONE |
|
|
|
|
Plan resubmittals received | | | 7/19/2012 | | |
|
|
|
Received 1 new site plan, 1 new manual J and 2 new sets of plans, and re-routed to Planning & Mechanical//BAS
|
Routing - PLANNING | 7/19/2012 | | 7/19/2012 | | PASS |
David Moser
|
|
|
Note: The house complies with the 100 foot setback line as per the plat note.
|
Routing - MECHANICAL | 7/19/2012 | | 7/19/2012 | | PASS |
Troy James
|
|
|
|
Routing - MECHANICAL | 7/17/2012 | | 7/17/2012 | | PASS |
Troy James
|
|
|
|
Route to Impact Fee Review | 7/10/2012 | 7/13/2012 | 7/16/2012 | | PASS |
Cindy M. Gould
|
|
|
|
Routing - MECHANICAL | 7/11/2012 | | 7/16/2012 | | FAIL |
Troy James
|
|
|
emailed corrections to western heating
|
Routing - PLANNING | 7/11/2012 | | 7/11/2012 | | FAIL |
David Moser
|
|
|
Building is within the rear yard setback. Called and emailed the applicant on 7-11-12.
|
Routing - PUBLIC WORKS | 7/10/2012 | | 7/11/2012 | | PASS |
Connie Baumgartner
|
|
|
|
Application received | | 7/10/2012 | 7/10/2012 | | DONE |
|
|
|
|
Routing - Addressing | 7/10/2012 | | 7/10/2012 | | PASS |
Terry Records
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 7/10/2012 | | DONE |
Alexandra L. DeYoung
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 7/10/2012 | | |
|
|
|
|
Intake Approval | | | 7/10/2012 | | PASS |
|
|
|
|