BLD-Final | 11/20/2012 | 11/21/2012 | 11/21/2012 | P | PASS |
Mike Jordan
|
|
|
Cameron Phone #: ###-####
|
DOC - Permit Finaled | 11/21/2012 | 11/21/2012 | 11/21/2012 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 11/19/2012 | 11/20/2012 | 11/20/2012 | P | FAIL |
Mike Jordan
|
|
|
Cameron-please call for access code Phone #: ###-####. Provide the blower door test result and energy cert.
|
BLD-Wall Bracing | 10/2/2012 | 10/3/2012 | 10/3/2012 | A | PASS |
Tom Arcoraci
|
|
|
Cameron Phone #: ###-####
|
BLD-Framing/Rough-in | 9/27/2012 | 9/28/2012 | 9/28/2012 | P | PASS |
Mike Jordan
|
|
|
cameron Phone #: ###-####
|
BLD-Energy code compliance | 9/28/2012 | 9/28/2012 | 9/28/2012 | P | PASS |
Mike Jordan
|
|
|
cameron Phone #: ###-####
|
BLD-Framing/Rough-in | 9/26/2012 | 9/27/2012 | 9/27/2012 | A | FAIL |
Mike Jordan
|
|
|
cameron Phone #: ###-####. Complete lateral bracing, see engineering, provide bracing on top chords of C2A trusses at overbuild. Provide alll required blocking for interior wall bracing per IRC 602.10.6. Correction notice posted. Ok to insulate.
|
BLD-Wall Bracing | 9/18/2012 | 9/19/2012 | 9/19/2012 | A | PASS |
Mike Jordan
|
|
|
cameron Phone #: ###-####. Wall bracing ok to cover.
|
BLD-Wall Bracing | 9/17/2012 | 9/18/2012 | 9/18/2012 | A | FAIL |
Mike Jordan
|
|
|
cameron Phone #: ###-####. Block panel splices @portal frame and nail at 3" oc with 8d nails. See portal frame detail and complete nailing pattern at upper section. Renail all areas, nailing is over spaced adn several areas missed. Correction notice posted.
|
BLD-Wall Bracing | 9/13/2012 | 9/17/2012 | 9/17/2012 | A | FAIL |
Mike Jordan
|
|
|
Shear - Cameron Phone #: ###-####. Provide city set of approved plans. Correction notice posted.
|
BLD-Wall Bracing | 9/13/2012 | 9/14/2012 | 9/14/2012 | A | PASS |
Mike Jordan
|
|
|
Cameron Phone #: ###-####
|
BLD-Footing | 8/21/2012 | 8/22/2012 | 8/22/2012 | A | PASS |
Mike Jordan
|
|
|
BILL Phone #: ###-####
|
BLD-Footing | 8/20/2012 | 8/21/2012 | 8/21/2012 | P | NR |
Mike Jordan
|
|
|
bill Phone #: ###-####. No one on site, no forms constructed.
|
Issue PAID IN FULL permit | | | 8/20/2012 | | DONE |
Tisha Gallop
|
|
|
|
Plan assigned to (CDM) | | 7/17/2012 | 8/15/2012 | | PASS |
Carl D Madsen
|
|
|
|
Routing - PLAN CHECK | 8/13/2012 | | 8/15/2012 | | PASS |
Carl D Madsen
|
|
|
|
Case Summary (BLD) | | | 8/15/2012 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/15/2012 | | |
|
|
|
|
Inspection Record Card- Bld | | | 8/15/2012 | | DONE |
Barbara Stitt
|
|
|
|
Telephone call | | | 8/15/2012 | | DONE |
|
|
|
Spoke with Cameron permit ready fees given
|
Permit Ready to Issue | | | 8/15/2012 | | DONE |
|
|
|
|
Telephone call | | | 8/13/2012 | | DONE |
Tisha Gallop
|
|
|
called and left vm for Cameron Jayo Homes need one more copy of full size sheet A3-1(floor plan).
|
Routing - PLANNING | 8/13/2012 | | 8/13/2012 | | PASS |
David Moser
|
|
|
|
Routing - MECHANICAL | 8/13/2012 | | 8/13/2012 | | PASS |
Troy James
|
|
|
|
Plan resubmittals received | | | 8/10/2012 | | DONE |
Tisha Gallop
|
|
|
received one copy of mech. manuals, and two copies of 8-1/2" x 11" site plan and full size sheet plan sheet A3-1(floor plan) A2-1(rear and front elevation); put with plans and rerouted to planning, mechanical and plan check.
|
1st review completed | | | 7/30/2012 | | FAIL |
|
|
|
|
Routing - PLAN CHECK | 7/25/2012 | | 7/30/2012 | | FAIL |
Carl D Madsen
|
|
|
Failed pending planning approval. 7-30-12 CDM
|
Routing - MECHANICAL | 7/23/2012 | | 7/25/2012 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 7/23/2012 | | 7/23/2012 | | FAIL |
David Moser
|
|
|
Failed; the house is within the rear 30 foot setback as required by the R-1A zone. Called and talked with the applicant on 7-23-12
|
Routing - Addressing | 7/17/2012 | | 7/23/2012 | | PASS |
Terry Records
|
|
|
|
Routing - PUBLIC WORKS | 7/23/2012 | | 7/23/2012 | | PASS |
Connie Baumgartner
|
|
|
|
Route to Impact Fee Review | 7/17/2012 | 7/20/2012 | 7/19/2012 | | PASS |
Cindy M. Gould
|
|
|
|
Application received | | 7/17/2012 | 7/17/2012 | | DONE |
Christina Prado
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 7/17/2012 | | DONE |
Christina Prado
|
|
|
|
Intake Approval | | | 7/17/2012 | | PASS |
Christina Prado
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 7/17/2012 | | DONE |
Christina Prado
|
|
|
|