Telephone call | | | 7/11/2019 | | DONE |
|
|
|
emailed Scott.Matthews@weyerhaeuser.com the final value (first notice) because it came back for the 2nd time. No info for the parcel owner so looked at the owner info and moved the info to parcel owner
|
Second Notice | | 6/20/2019 | 7/10/2019 | | DONE |
|
|
|
mailed 7-11
|
First Notice | 5/14/2019 | 5/14/2019 | 6/10/2019 | | DONE |
Jim Storey
|
|
|
mailed 6-11
|
DOC - Permit Finaled | 5/14/2019 | 5/14/2019 | 5/14/2019 | P | PASS |
Jim Storey
|
|
|
|
BLD-Footing | 9/21/2012 | 9/21/2012 | 9/21/2012 | P | PASS |
Tom Arcoraci
|
|
|
Scott Phone #: ###-####
|
BLD-Foundation | 9/21/2012 | 9/21/2012 | 9/21/2012 | P | PASS |
Tom Arcoraci
|
|
|
Scott Phone #: ###-####
|
OVERRIDE | | | 9/21/2012 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 9/21/2012 | | DONE |
Christina Prado
|
|
|
|
Inspection Record Card- Bld | | | 9/21/2012 | | DONE |
Christina Prado
|
|
|
|
Permit Ready to Issue | | | 9/21/2012 | | DONE |
Christina Prado
|
|
|
|
Plan assigned to (TLW) | 9/18/2012 | | 9/18/2012 | | DONE |
Tim L. Woodard
|
|
|
|
Routing - PLAN CHECK | 9/18/2012 | | 9/18/2012 | | PASS |
Tim L. Woodard
|
|
|
|
1st review completed | | | 9/18/2012 | | DONE |
Tim L. Woodard
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/18/2012 | | DONE |
Tim L. Woodard
|
|
|
|
Routing - Erosion and Sediment | 9/6/2012 | | 9/6/2012 | | PASS |
Kimberly M. Johnson
|
|
|
Waiver request approved.
|
Payment Received | | | 9/5/2012 | | DONE |
|
|
|
Payment received via Govolutions
|
Telephone call | | | 9/5/2012 | | |
|
|
|
9-5-12 sent Scott email that initial fee needs to be paid before permit can move on ///dld
|
Intake Approval | | | 9/5/2012 | | PASS |
Tim L. Woodard
|
|
|
|
Intake Approval | | | 8/30/2012 | | FAIL |
Tim L. Woodard
|
|
|
Please reupload drawings in compliance with the #518 Minor Tenant Improvement Checklist and the Electronic Submittal Guide. I will email both items to you for your review. A few things that I identified with a quick review would be the minimum size plan sheet is not met with the drawings, no engineering for the foundation or floor was submitted, site plan cannot be reused due to copy wright provisions attached to previous architects plans, upload the #518 checklist, upload form #304 Register Design Proffessional Form, Upload plan waiver letter for Erosion Sediment Control, Provide a cross section identifying j-bolts and sill plate connection, and a new cover sheet with all the items that are on the cover sheet submitted.
Call Tim Woodard or Perry Paine with questions;
###-#### (Tim) or ###-#### (Perry)
|
Application received | | | 8/28/2012 | | DONE |
|
|
|
Application submitted via PDS Online on Aug 28 2012 3:58PM
|