BLD-Final | 4/30/2013 | 4/30/2013 | 4/30/2013 | P | PASS |
Mike Jordan
|
|
|
Phone #: 6088231 >> Inspection requested via mobile web by Rustin
|
DOC - Permit Finaled | 4/30/2013 | 4/30/2013 | 4/30/2013 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Energy code compliance | 12/31/2012 | 12/31/2012 | 12/31/2012 | P | PASS |
Jim Storey
|
|
|
Phone #: 6088231 >> Inspection requested via mobile web by Rustin
|
BLD-Framing/Rough-in | 12/26/2012 | 12/27/2012 | 12/27/2012 | A | PASS |
Jim Storey
|
|
|
Phone #: 6088231 >> Inspection requested via mobile web by Rustin
|
BLD-Wall Bracing | 12/21/2012 | 12/21/2012 | 12/21/2012 | P | PASS |
Mike Jordan
|
|
|
Phone #: 6088231 >> Inspection requested via mobile web by Rustin. Exterior wall bracing only ok.
|
BLD-Framing/Rough-in | 12/21/2012 | 12/21/2012 | 12/21/2012 | P | FAIL |
Mike Jordan
|
|
|
Phone #: 6088231 >> Inspection requested via mobile web by Rustin. Airseal pacage must be completed prior to framing inspection, Provide full length header over window in laundry room, strap top plate at gas pipe penetration, Strap double 1.75x11.7/8 LVL to 6x6 post, provide truss layout planfireblock ceiling furdown @ closet behind staircase,Provide blocking one joist space to LSTA strap per attached engineering, Entry stairway tall wall to be framed at 12" o.c. per attached engineering (#4) Correction notice posted, do not insulate.
|
BLD-Wall Bracing | 12/18/2012 | 12/19/2012 | 12/19/2012 | A | FAIL |
Mike Jordan
|
|
|
Phone #: 6088231 >> Inspection requested via mobile web by Rustin. Pick up missing shear panel, noted on approved plan. Majority of staples over driven, restaple.
|
BLD-Wall Bracing | 12/17/2012 | 12/18/2012 | 12/18/2012 | A | NR |
Mike Jordan
|
|
|
Phone #: 6088231 >> Inspection requested via mobile web by Rustin. Provide the city set of approved plans, correction notice posted. Must complete all ESC issues prior to wall bracing inspection.
|
Plan resubmittals received | | | 12/12/2012 | | DONE |
|
|
|
new acca report
|
Routing - MECHANICAL | 12/12/2012 | | 12/12/2012 | | PASS |
Troy James
|
|
|
resubmitted acca report
|
BLD-Foundation | 11/12/2012 | 11/13/2012 | 11/13/2012 | A | PASS |
Tom Arcoraci
|
|
|
Phone #: 6088231 >> Inspection requested via mobile web by Rustin
|
BLD-Footing | 11/7/2012 | 11/8/2012 | 11/8/2012 | A | PASS |
Jim Storey
|
|
|
Phone #: ###-#### >> Inspection requested via web by Ben Sears
|
OVERRIDE | | | 11/7/2012 | | |
|
|
|
|
Plan assigned to (CDM) | 10/8/2012 | 10/8/2012 | 11/7/2012 | | PASS |
Carl D Madsen
|
|
|
|
Issue PAID IN FULL permit | | | 11/7/2012 | | DONE |
Barbara Stitt
|
|
|
|
Plan resubmittals received | | | 11/7/2012 | | DONE |
|
|
|
Tall wall engineering and shear wall engineering 11-7-12 CDM
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/7/2012 | | |
|
|
|
|
Inspection Record Card- Bld | | | 11/7/2012 | | DONE |
Barbara Stitt
|
|
|
|
Permit Ready to Issue | | | 11/7/2012 | | DONE |
Barbara Stitt
|
|
|
|
Route to Impact Fee Review | 10/8/2012 | 10/11/2012 | 10/16/2012 | | PASS |
Cindy M. Gould
|
|
|
|
Routing - PLAN CHECK | 10/11/2012 | | 10/16/2012 | | PASS |
Carl D Madsen
|
|
|
|
1st review completed | | | 10/16/2012 | | FAIL |
|
|
|
|
Case Summary (BLD) | | | 10/16/2012 | | DONE |
|
|
|
|
Routing - MECHANICAL | 10/10/2012 | | 10/11/2012 | | PASS |
Troy James
|
|
|
|
Routing - PLANNING | 10/9/2012 | | 10/10/2012 | | PASS |
David Moser
|
|
|
|
Routing - Addressing | 10/8/2012 | | 10/9/2012 | | PASS |
April Wing
|
|
|
|
Routing - PUBLIC WORKS | 10/8/2012 | | 10/9/2012 | | PASS |
Connie Baumgartner
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 10/8/2012 | | DONE |
Tisha Gallop
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 10/8/2012 | | DONE |
Tisha Gallop
|
|
|
|
Intake Approval | | | 10/8/2012 | | PASS |
Tisha Gallop
|
|
|
|
Application received | | 10/8/2012 | | | |
|
|
|
|