Permit Information
Permit NumberBLD12-02915
StatusFinaled
Name STEED CONSTRUCTION
Site Address 4017 W OVERLAND RD
Project NameBiomat Freezer Upgrade
Customer Number 
ePlanReviewNo
Description
(BIOMAT USA – Freezer expansion) Permit is to remodel an existing 11,548 sq. ft. office tenant space. This building is sprinklered for building area increase. Approval contingent upon adhering to the approved plans on file. Work to include: installation of new freezer wall panels (thermal barrier not required), installation of a new chain-link fence around new condensing unit, and interior finishes in accordance with Ch. 8 of the 2009 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire department. **TLW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Follow up  10/9/2013 DONE
DetailsTisha Gallop
Print Statement  10/9/2013 DONE
DetailsTisha Gallop
mailed to Steed Const
Third Notice 9/4/201310/1/2013 DONE
9/11/13 contractor called said will send it in next couple of days --- mailed with letter 9/30/13
Third Notice 8/4/20138/30/2013 DONE
mailed to Steed
Third Notice 7/7/20137/30/2013 DONE
faxed
Telephone call  7/8/2013 DONE
DetailsTisha Gallop
called Jason Hibbard/Steed Const and left vm received FV over fax; need real final values not copy of initial, including ele, mech, & plmb.
Third Notice 6/9/20137/2/2013 DONE
faxed
Second Notice 5/3/20136/4/2013 DONE
DetailsChristina Prado
mailed 6-5-13
First Notice4/9/20134/9/20134/23/2013 DONE
DetailsTom Arcoraci
BLD-Final4/8/20134/9/20134/9/2013APASS
DetailsTom Arcoraci
Tim-PLease call prior to inspection Phone #: ###-####
DOC - Permit Finaled4/9/20134/9/20134/9/2013PPASS
DetailsTom Arcoraci
FIRE-Final Inspection4/8/20134/8/20134/8/2013PPASS
DetailsForrest France
Fire life safety final approved.
FIRE-Final Inspection4/4/20134/5/20134/5/2013PPASS
DetailsTroy Cobbley
Fire life safety passed
FIRE-Final Inspection2/20/20132/21/20132/21/2013AFAIL
DetailsForrest France
Modifications to the fire alarm system will be necessary due to remodel work (FIR permit required). Remainder of fire life safety inspection items passed.
BLD-Final2/20/20132/21/20132/21/2013ANR
DetailsTom Arcoraci
Tim-PLease call prior to inspection Phone #: ###-####
FIRE-Conference2/12/20132/12/20132/12/2013PDONE
DetailsTroy Cobbley
This entry is for future inspectors note. I noted the the existing ceiling mounted horn/strobe spacing appears to be blocked by the new freezer walls.
Issue PAID IN FULL permit  11/21/2012 DONE
DetailsTisha Gallop
Plan assigned to (TLW)11/13/2012 11/19/2012 PASS
DetailsTim L. Woodard
Routing - PLAN CHECK11/13/2012 11/19/2012 PASS
DetailsTim L. Woodard
Permit approved with structural calculation attached on 7 ft. fence. TLW
Routing - PLANNING11/19/2012 11/19/2012 PASS
DetailsSarah Schafer
No Zoning cert required for Chain link fence behind building per: Sarah Schafer / Colleen Carroll. TLW
1st review completed  11/19/2012 DONE
DetailsTim L. Woodard
PLANS/APPL TAKEN TO FRONT DESK  11/19/2012 DONE
DetailsTim L. Woodard
Case Summary (BLD)  11/19/2012 DONE
DetailsTim L. Woodard
Inspection Record Card- Bld  11/19/2012 DONE
Telephone call  11/19/2012 DONE
DetailsChristina Prado
called Tom to advise permit is ready and gave fees due
Permit Ready to Issue  11/19/2012 DONE
DetailsChristina Prado
Plans ACCEPTED BY PLAN TECH  11/13/2012 DONE
DetailsChristina Prado
Intake Approval  11/13/2012 PASS
DetailsTim L. Woodard
Recd Pcfee & Taken To Pln CK  11/13/2012  
DetailsChristina Prado
Intake Approval  11/8/2012 FAIL
DetailsTim L. Woodard
Tom,

Please upload the #518 Checklist and also form #304 Registered Design Proffessional form into the Documents folder of this case. Please modify the plan sheets to comply with the Electronic Submittal Guide. The Electronic submittals required a clear stamping area provided 3 inches off the bottom right corner for "Batch Stamping".

Thanks.

Call if you have any questions.
Tim Woodard
208 384 3817
Application received  11/2/2012 DONE
Application submitted via PDS Online on Nov 2 2012 3:05PM