Permit Information
Permit NumberBLD12-03192
StatusFinaled
Name CHURCH OF JESUS CHRIST LATTER DAY S
Site Address 10740 W FAIRVIEW AVE
Project NameBOISE BISHOP STOREHOUSE
Customer Number 
ePlanReviewNo
Description
(RACKING PERMIT - racks within walk-in freezer)Per Idaho Statustes 54-5205 tenant is owner and acting as contractor ok per Jason Blais--12-13-12// To install a engineered steel rack system, declared by engineer to have been designed in compliance with 2008 RMI/ANSI Design Manual, within an existing walk-in freezer installed under BLD12-02749. There will be three steel storage racks. All racks will be 3'-6" in depth; one eight foot in length and two 4' in length. The rack frame height is 16' in height. Plans & engineering indicate three shelving levels at 54" on center with a maximum load per shelf of 4,000 pounds declared in engineering design data. Each column is centered on and supported on an 8" x 8" x 1/2" steel plate with a minimum of two ITW Red Head TRUBOLT Wedge Anchors per ESR-2427 (copy attached) with minimum embed of 3-1/4" into concrete floor. The owner is responsible for displaying a permenant plaque, not less than 50 sq. in. in area stating the maximum unit load and/or maximum uniformly distributed load per level, etc. in accordance with Section 1.4.2 of 2008 RMI (see attached plan review comments). Special Inspection is required for Red Head Trubolt wedge anchor installation per ESR report and for any field welding (if applicable). See Statement of Special Inspection attached to plans. MTI designated as Special Inspection Firm per e-mail from Charles Olsen, Bishops Storehouse representative. Separate applications and permit are required for modification to the sprinkler system (NFPA 13) and the alarm system (NFPA 72) before any work is begun, as regulated by the Boise City Fire Department. drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/20/201212/20/201212/20/2012APASS
DetailsJim Sly
DOC - Permit Finaled12/20/201212/20/201212/20/2012PPASS
DetailsJim Sly
FIRE-Final Inspection12/14/201212/18/201212/18/2012APASS
DetailsTroy Cobbley
Life safety passed
Issue PAID IN FULL permit  12/13/2012 DONE
DetailsBarbara Stitt
Plan assigned to (DRS)12/6/201212/6/201212/12/2012 PASS
DetailsDan Stuart
Routing - FIRE12/10/2012 12/12/2012 PASS
DetailsScott Arellano
Plans are approved as shown. A separate Fire Sprinkler permit is required.
1st review completed  12/12/2012 PASS
Routing - PLAN CHECK12/12/2012 12/12/2012 PASS
DetailsDan Stuart
Plans to permit desk to process and issue permit.
PLANS/APPL TAKEN TO FRONT DESK  12/12/2012 PASS
Inspection Record Card- Bld  12/12/2012 DONE
DetailsChristina Prado
Telephone call  12/12/2012 DONE
LM for charles permit ready fees given need gc
Permit Ready to Issue  12/12/2012 DONE
Routing - PLAN CHECK12/6/2012 12/10/2012 PASS
DetailsDan Stuart
Approved with comments attached. Routing to fire code anlyst for review.
Plans ACCEPTED BY PLAN CHECK  12/6/2012 DONE
DetailsDan Stuart
Plans accepted for intake. Owner rep to email a completed Statement of Special Inspection document for the rack anchorage bolts installation in hardended concrete,directly to me. Required before permit can be issued.
Intake Approval  12/6/2012 PASS
DetailsDan Stuart
Recd Pcfee & Taken To Pln CK  12/6/2012 DONE
DetailsChristina Prado
CHANGE STATUS TO (REV)  12/6/2012 DONE
DetailsChristina Prado
Application received 12/6/2012