Permit NumberBLD13-00048
StatusFinaled
Name MCCOWN MCCOWN INC
Site Address 2106 N 21ST ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Permit for the construction of a new 3131 sq. ft., two story (first story 1724 sq. ft., second story 1210 sq. ft. and the Basement is 197 sq. ft.) single family dwelling with 4 bedrooms, 3 bathrooms, approximately 200 sq. ft. of covered patio/porch per the approved plans, plan review report and any notations. R-1C zoning and setbacks per planning. CDM
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/5/201312/6/201312/6/2013APASS
DetailsTony Young
Daniel Phone #: ###-####
DOC - Permit Finaled12/6/201312/6/201312/6/2013PPASS
DetailsTony Young
c of o issued
BLD-Energy code compliance10/11/201310/14/201310/14/2013APASS
DetailsTony Young
Dan Phone #: ###-####
BLD-Framing/Rough-in10/11/201310/11/201310/11/2013PPASS
DetailsTony Young
Dan Phone #: ###-####
BLD-Framing/Rough-in10/10/201310/10/201310/10/2013PNR
DetailsTony Young
ok to cover insepction please-Dan Phone #: ###-####,, need fire blocks at ceiling lines and chase tops,,, seal interior walls,, caulk sole plates on exterior walls
Plan resubmittals received  9/17/2013 DONE
new manual j
Routing - MECHANICAL9/17/2013 9/17/2013 PASS
DetailsTroy James
resubmitted manual j
BLD-Framing/Rough-in9/12/20139/12/20139/12/2013PPASS
DetailsJim Sly
doug Phone #: ###-####
BLD-Conference8/26/20138/27/20138/27/2013AFAIL
DetailsTony Young
Dan Phone #: ###-####,, c/n on trusses,, twisted,, bearing size,, split,, etc,, need ok or fix from engioneer
BLD-Wall Bracing8/14/20138/14/20138/14/2013PPASS
DetailsTom Arcoraci
dan Phone #: ###-####
BLD-Conference7/24/20137/24/20137/24/2013PPASS
DetailsTony Young
daniel Phone #: ###-####,, frame ?
BLD-Conference5/30/20135/30/20135/30/2013PPASS
DetailsTony Young
noise complaint at 6:45 am,, no ordinance
BLD-Foundation5/30/20135/30/20135/30/2013PPASS
DetailsTony Young
Cal; Phone #: ###-####
BLD-Footing5/28/20135/28/20135/28/2013PPART
DetailsTony Young
Cal Phone #: ###-####,, work in progress
BLD-Foundation5/16/20135/17/20135/17/2013APART
DetailsTony Young
CAL Phone #: ###-####,, basement wall
BLD-Foundation5/16/20135/16/20135/16/2013PPART
DetailsTony Young
CAL Phone #: ###-####,, work in progress on the basement wall
BLD-Footing5/15/20135/15/20135/15/2013PPART
DetailsTony Young
Phone #: ###-####,, basement footing per plan
Issue PAID IN FULL permit  5/2/2013 DONE
DetailsChristina Prado
OVERRIDE  3/20/2013  
Plan assigned to (AJS)3/12/20133/12/20133/20/2013 DONE
DetailsAdele J Schaffeld-Griffin
PLANS/APPL TAKEN TO FRONT DESK  3/20/2013 DONE
Permit Ready to Issue  3/20/2013 DONE
DetailsAdele J Schaffeld-Griffin
Case Summary (BLD)  3/20/2013 DONE
DetailsAdele J Schaffeld-Griffin
Inspection Record Card- Bld  3/20/2013 DONE
DetailsBarbara Stitt
Telephone call  3/20/2013 DONE
DetailsChristina Prado
called daniel to advise permit is ready and gave fees due
Permit Ready to Issue  3/20/2013 DONE
DetailsChristina Prado
Routing - MECHANICAL3/19/2013 3/19/2013 FAIL
DetailsTroy James
emailed corrections to Western Heating
Routing - MECHANICAL3/19/2013 3/19/2013 PASS
DetailsTroy James
Routing - PLANNING3/15/2013 3/18/2013 PASS
DetailsColleen T Carroll
Routing - PLAN CHECK3/15/2013 3/15/2013 PASS
DetailsAdele J Schaffeld-Griffin
Routing - MECHANICAL3/14/2013 3/15/2013 FAIL
DetailsTroy James
talked to Ival about a couple corrections from previous correction notice.
Plan resubmittals received  3/14/2013 DONE
DetailsChristina Prado
received two sets of plans marked 1, 2, 3, 4, 5, 6, rescheck, manual j & spray foam evalutions;reoute to Adele for review
Routing - MECHANICAL3/13/2013 3/13/2013 FAIL
DetailsTroy James
emailed corrections to western heating
Plan assigned to (CDM)3/5/20133/5/20133/12/2013 DEFR
DetailsCarl D Madsen
Plans assigned to Adele
Plan resubmittals received  3/12/2013 DONE
DetailsTisha Gallop
Per Colleen Carroll request; received 8 1/2 x 11 elevation and floor plan of existing detached garage; put with plans at Colleens desk.
1st review completed  3/12/2013 FAIL
DetailsAdele J Schaffeld-Griffin
email sent 3/12/13
Routing - MECHANICAL3/7/2013 3/11/2013 FAIL
DetailsTroy James
emailed western heating corrections
Route to Impact Fee Review3/5/20133/8/20133/7/2013 PASS
DetailsCindy M. Gould
Routing - PLANNING3/6/2013 3/7/2013 FAIL
DetailsColleen T Carroll
Existing SFD per Bld08-02582 needs to be converted back to garage.
Routing - Addressing3/5/2013 3/6/2013 PASS
DetailsJason C. Taylor
Routing - PUBLIC WORKS3/6/2013 3/6/2013 PASS
DetailsConnie Baumgartner
Issue PAID IN FULL permit  3/5/2013 DONE
Payment received via Govolutions
Plans ACCEPTED BY PLAN TECH  3/5/2013 DONE
DetailsBarbara Stitt
Intake Approval  3/5/2013 PASS
DetailsBarbara Stitt
Intake Approval  2/19/2013 FAIL
DetailsTisha Gallop
Application received  1/10/2013 DONE
Application submitted via PDS Online on Jan 10 2013 11:46AM
Routing - PLAN CHECK3/11/2013   FAIL
DetailsAdele J Schaffeld-Griffin
email sent 11/12/13
I have competed the 1st plan review for the project listed above under the 2009 IRC. Please provide 2 set of revised documents or additional documents.

1. Commercial ranges are not permitted in residential homes. Please clarify that the range installed with be listed for residential use.
2. Please indicate the method of damp proofing that will be installed on the stem walls/ basement walls. R406
3. Landings are required at the top and bottom of all stairs. Please provide a min 3x3 landing at the top of the stairs from the basement. R311.7.5
4. Please indicate the footings and footing size for the front porch load bearing post.
5. Please provide a complete cross section of the building. Please see the submittal check list for specific information needed on the plans.
The footing and floor joist size is shown on the foundation page but the distance from grade to the bottom of joist is not shown, floor sheathing, siding material, under floor insulation, the distance from exterior siding to grade, anchor bolts size and spacing, P.T plate and etc.
The plans reference 2x6 construction but does not indicate spacing, wall interior and exterior finishes, spacing required from concrete for basement wall locations and etc.
6. Please indicate attic access location and size.
7. Please note all safety glazing locations on the plans.
8. The reinforcement called out for the 8 foot basement wall does not meet the minimum requirements from T404.1.1(2). Vertical reinforcement would need to be every 48 inches instead of 72 inches as noted on the plans.
9. Please indicate how the requirements for roof ventilation will be met. R806
10. Please provide 2 copies of the specific ICC-ES Evaluation Service Report for the spay foam insulation that is indicated on the plans. R316.3
11. Please provide a complete stairway detail. Please include handrails, guardrail information. R311.7.7.1 and R312.

If you have any questions please refer to the New Residential Check list or please call and I will be happy to go over these items with you.

Adele J. Schaffeld-Griffin
City of Boise
Plans Examiner II
###-####