BLD-Final | 8/12/2013 | 8/12/2013 | 8/12/2013 | P | PASS |
Mike Jordan
|
|
|
|
DOC - Permit Finaled | 8/12/2013 | 8/12/2013 | 8/12/2013 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 8/12/2013 | 8/12/2013 | 8/12/2013 | A | NR |
Mike Jordan
|
|
|
Please call 1/2hr prior.
Thanks Jim Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Wall cover | 6/26/2013 | 6/26/2013 | 6/26/2013 | P | PASS |
Mike Jordan
|
|
|
Interior firewall.
|
BLD-Energy code compliance | 6/26/2013 | 6/26/2013 | 6/26/2013 | A | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Energy code compliance | 6/26/2013 | 6/26/2013 | 6/26/2013 | A | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin. ok to cover.
|
BLD-Framing/Rough-in | 6/25/2013 | 6/25/2013 | 6/25/2013 | P | PASS |
Jim Sly
|
|
|
Please call 1/2 prior Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Framing/Rough-in | 6/24/2013 | 6/24/2013 | 6/24/2013 | P | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin. Box out electrical ground in garage at 1 hr. wall. Remove all expanded foam in penetrations and provide fire caulking at 1hr. wall. Provide adequate bearing for floor truss at garage moment frame and strap top plates. Fireblock wall understairs at furdown. Strap top plates at DWV penetration at wall 1st flight of stairs. Nail off J09 truss as per engineering and provide complete bearingat exterior wall.. Several fixtures at 2nd floor ceiling not caulked. FFireblock wall at barrel vault. Correction notice posted.
|
BLD-Framing/Rough-in | 6/24/2013 | 6/24/2013 | 6/24/2013 | P | CANC |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Energy code compliance | 6/24/2013 | 6/24/2013 | 6/24/2013 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Framing/Rough-in | 6/14/2013 | 6/14/2013 | 6/14/2013 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin. Needs to complete airseal package.
|
BLD-Wall Bracing | 5/28/2013 | 5/28/2013 | 5/28/2013 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Wall Bracing | 5/21/2013 | 5/22/2013 | 5/22/2013 | A | PASS |
Mike Jordan
|
|
|
Shear firewall construction. Zippidy do da Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Wall Bracing | 5/16/2013 | 5/16/2013 | 5/16/2013 | P | PART |
Mike Jordan
|
|
|
Moment frame Phone #: ###-#### >> Inspection requested via web by James Larkin. Need special inspection.
|
BLD-Wall Bracing | 5/7/2013 | 5/7/2013 | 5/7/2013 | A | PASS |
Tom Arcoraci
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin wip ok
|
BLD-Footing | 4/29/2013 | 4/30/2013 | 4/30/2013 | A | PASS |
Mike Jordan
|
|
|
Greg Phone #: ###-####
|
BLD-Energy code compliance | 4/25/2013 | 4/25/2013 | 4/25/2013 | P | PASS |
Mike Jordan
|
|
|
greg Phone #: ###-####. Rigid foam insulation, interior side of stem wall.
|
BLD-Foundation | 4/12/2013 | 4/16/2013 | 4/16/2013 | P | PASS |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 4/12/2013 | 4/15/2013 | 4/15/2013 | P | PASS |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
Issue PAID IN FULL permit | | | 4/10/2013 | | DONE |
Barbara Stitt
|
|
|
|
OVERRIDE | | | 4/4/2013 | | |
|
|
|
|
Plan assigned to (AJS) | 3/6/2013 | 3/6/2013 | 4/4/2013 | | DONE |
Adele J Schaffeld-Griffin
|
|
|
need planning sign off
|
Routing - PLANNING | 3/29/2013 | | 4/4/2013 | | PASS |
Sue Cummings
|
|
|
DO NOT ISSUE UNTIL APPEAL PERIOD HAS LAPSED ON 4/4/13
|
Case Summary (BLD) | | | 4/4/2013 | | DONE |
Adele J Schaffeld-Griffin
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/4/2013 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 4/4/2013 | | DONE |
Barbara Stitt
|
|
|
|
Permit Ready to Issue | | | 4/4/2013 | | DONE |
Barbara Stitt
|
|
|
E-mailed Jim with fees on 4-4-13 @ 11:40am///BAS
|
Routing - PLAN CHECK | 4/4/2013 | | 4/4/2013 | | PASS |
Adele J Schaffeld-Griffin
|
|
|
Adele
|
Routing - PLANNING | 2/22/2013 | | 3/29/2013 | | FAIL |
Sue Cummings
|
|
|
Cu mod. CUP13-11 approved 3/25/13. Builder has maxed out the limit of allowed single garages. Will do a CU mod to provide additional parking.
|
Plan assigned to (CDM) | 2/21/2013 | 2/21/2013 | 3/6/2013 | | DEFR |
Carl D Madsen
|
|
|
assigned to Adele
|
1st review completed | | | 3/6/2013 | | FAIL |
Adele J Schaffeld-Griffin
|
|
|
need planning approval
|
Routing - MECHANICAL | 2/27/2013 | | 3/4/2013 | | FAIL |
Troy James
|
|
|
emailed corrections to Dustin Mori
|
Routing - MECHANICAL | 3/4/2013 | | 3/4/2013 | | PASS |
Troy James
|
|
|
|
Route to Impact Fee Review | 2/20/2013 | 2/25/2013 | 2/26/2013 | | PASS |
Cindy M. Gould
|
|
|
|
Routing - Addressing | 2/21/2013 | | 2/22/2013 | | PASS |
Jason C. Taylor
|
|
|
|
Routing - PUBLIC WORKS | | | 2/22/2013 | | PASS |
Connie Baumgartner
|
|
|
|
Application received | | 2/20/2013 | 2/20/2013 | | DONE |
Barbara Stitt
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 2/20/2013 | | DONE |
Barbara Stitt
|
|
|
|
Intake Approval | | | 2/20/2013 | | PASS |
Barbara Stitt
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 2/20/2013 | | DONE |
Barbara Stitt
|
|
|
|