Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD13-00644
StatusFinaled
Name PINK CAKE BOX LLC
Site Address 217 S ROOSEVELT ST
Project NameAmaru Confections
Customer Number 
ePlanReviewYes
Description
(AMARU CONFECTIONS) This permit if for the conversion of an existing enclosed parking garage and office, BLD04-02894 to a wholesale/commercial bakery (non-retail). Scope of project shall include plumbing, mechanical as shown on the approved plans. The accessible bathroom in the office is the approved bathroom facility for the coffee shop and shall remain as such. Building History- (EXECUTIVE PLUMBING / COFFEE FOR YOU) To refurbish existing 1008 sq. ft. building for use as office and enclosed parking garage. Work includes remodel of one existing restroom and access thereto for full accessibility compliance for use by coffee shop & office personnel; to add new accessible breakroom area, new HVAC system and upgrade exterior windows. To construct a stand alone 196 sq. ft. building and finish out for drive-up coffee shop, all per approved plans to include red-lined notes thereon and attached plan review comments of all reviewing agencies. drs
– The building appears to have originally been a service station. In 1973 the building was purchased for use as Hopkins Auto Glass and remodeled to meet their needs in August 1972 through November 1973. The 1970 UBC was in effect at that time. A certificate of occupancy, #1599, was issued to Hopkins Auto Glass on 6/10/75. Hopkins Glass occupied the existing building until 2002 per city directory.
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 7/3/20137/8/2013 DONE
Second Notice 6/14/20136/28/2013 DONE
mailed 7-1-13
First Notice 5/17/20136/4/2013 DONE
Permanent Occupancy  5/7/2013 DONE
DetailsBarbara Stitt
FIRE-Final Inspection5/2/20135/3/20135/3/2013APASS
DetailsForrest France
Life safety inspection passed.
BLD-Final5/2/20135/3/20135/3/2013PPASS
DetailsTom Arcoraci
Chris Wyatt-PLease call at least 20 mins prior to insepction Phone #: ###-####
Routing - PLUMBING4/19/2013 4/19/2013 PASS
DetailsDaryl Spivey
Add 2 inch drain as marked on plans for walk in cooler condensate drain.
PLANS/APPL TAKEN TO FRONT DESK  4/19/2013 DONE
DetailsAdele J Schaffeld-Griffin
Print Occupancy Form  4/19/2013 DONE
DetailsChristina Prado
Permit Ready to Issue  4/19/2013 DONE
DetailsChristina Prado
Issue PAID IN FULL permit  4/19/2013 DONE
DetailsChristina Prado
Print Occupancy Form  4/19/2013 DONE
DetailsChristina Prado
Print Occupancy Form  4/19/2013 DONE
DetailsTisha Gallop
Plan assigned to (AJS)4/2/2013 4/19/2013 PASS
DetailsAdele J Schaffeld-Griffin
1ST REVIEW COMPLETED
Routing - PLAN CHECK4/18/2013 4/18/2013 PASS
DetailsAdele J Schaffeld-Griffin
Recieved document from owner on removal of toilet.
Routing Off Site - C.D.H4/18/2013 4/18/2013 PASS
DetailsAdele J Schaffeld-Griffin
signed off in e plan with notes
Routing - PLUMBING4/17/2013 4/17/2013 FAIL
DetailsDaryl Spivey
Provide engineered set of plumbing plans.
Routing - MECHANICAL4/16/2013 4/16/2013 PASS
DetailsTroy James
Routing PW Solid Waste4/3/2013 4/10/2013 PASS
DetailsPeter J. McCullough
approved in e plan review by Peter McCullough, no site improvements proposed, interior only
Routing PW Environmental4/3/2013 4/10/2013 PASS
DetailsWalt Baumgartner
approved, sewere pretreatment jurisdiction bench sewer district ###-#### comments per Walt Bumgartner in e plan review
Routing PW Drainage4/3/2013 4/10/2013 PASS
DetailsBrian Murphy
no review needed as per Brian Murphy in e plan review
1st review completed  4/10/2013 FAIL
DetailsAdele J Schaffeld-Griffin
Routing - MECHANICAL4/2/2013 4/8/2013 FAIL
DetailsTroy James
Look at bread ovens. TLW
Eplan
Routing - PLUMBING4/2/2013 4/3/2013 FAIL
DetailsBill VanDegrift
Changing plumbing out to new, OK per Bill no plumbing plan. TLW
This project is more that a fixture change out. The plans must address the following items.
1) move floor sink out of restroom into wash area.
2) vent floor sink trap.
3)show water system.
4)food prep sink waste may not be connected to other wastes.
5)include any grease abatement required by public works pretreatment on resubmittal.
6)include any additional requirements by the health department on resubmittal.
Routing - Addressing4/2/2013 4/3/2013 PASS
DetailsJason C. Taylor
Routing - PUBLIC WORKS4/2/2013 4/3/2013 PASS
DetailsBeverly Mountain
Routing PW Sewer Rating4/3/2013 4/3/2013 PASS
DetailsConnie Baumgartner
Payment Received  4/2/2013 DONE
Payment received via Govolutions
Intake Approval  4/2/2013 PASS
DetailsTim L. Woodard
Routing - Design Review4/2/2013 4/2/2013 PASS
DetailsAndrea Tuning
Application received  3/21/2013 DONE
Application submitted via PDS Online on Mar 21 2013 11:30AM
Case Summary (BLD)  3/21/2013 DONE
Routing Off Site - C.D.H4/2/2013   FAIL
DetailsAdele J Schaffeld-Griffin
1. Walk-in refrigerator must drain indirectly outside of walk-in 2. Existing shower to be converted to mop sink with vacuum breaker faucet 3. Place barrier on both sides of food prep sink 4. Close off door to complete wall with FRP behind hand wash and food prep sinks
comments from e plan review
Routing - PLAN CHECK4/2/2013   FAIL
DetailsAdele J Schaffeld-Griffin
Building Plan Reviewer AMARU - FLOOR PLAN REVISED a3.pdf Building Plan Review Changemarks note #01 Toilet rooms shall not open directly into a room used for preparation of food for service to the public. IBC section 1210.5 No
1 Building Plan Reviewer AMARU - SITE a1.pdf Building Plan Review Changemarks note #02 IBC section 306.2 specifically identifies bakeries as an F1 occupancy. Please revise code analysis. No
1 Building Plan Reviewer AMARU - SITE a1.pdf Building Plan Review Changemarks note #03 The current edition of ANSI-A117.1 is the 2003 edition, please revise code analysis. No
1 Building Plan Reviewer AMARU - SITE a1.pdf Building Plan Review Changemarks note #04 Please have the architect provide a statement on these plans that references building permit BLD04-02894, George McClean was the architect of record for this project. One of the existing bathrooms and access thereto from fully accessibility compliance for use by the coffee shop and office personnel.