First Notice | | 12/23/2013 | 12/24/2013 | | DONE |
Christina Prado
|
|
|
mailed 12-26-13
|
BLD-Final | 12/11/2013 | 12/13/2013 | 12/13/2013 | A | PASS |
Jim Sly
|
|
|
tom Phone #: ###-#### OK for Perm Occ.
|
Permanent Occupancy | | | 12/13/2013 | | DONE |
|
|
|
|
Permanent Occupancy | | | 12/13/2013 | | DONE |
|
|
|
|
FIRE-Final Inspection | 12/11/2013 | 12/12/2013 | 12/12/2013 | P | PASS |
Troy Cobbley
|
|
|
Life safety passed
|
BLD-Conference | 12/4/2013 | 12/5/2013 | 12/5/2013 | P | PASS |
Jim Sly
|
|
|
As late as possible Phone #: 2083534535 >> Inspection requested via mobile web by Tom Andrews Ceiling grid......OK.
|
Zoning Approval | 12/5/2013 | 12/5/2013 | 12/5/2013 | | PASS |
Josh Wilson
|
|
|
|
BLD-Energy code compliance | 11/1/2013 | 11/4/2013 | 11/4/2013 | A | PART |
Jim Sly
|
|
|
tom Phone #: ###-#### Ext. Walls.....OK.
|
BLD-Framing/Rough-in | 10/30/2013 | 10/31/2013 | 11/1/2013 | P | PASS |
Jim Sly
|
|
|
tom Phone #: ###-####
|
BLD-Framing/Rough-in | 10/21/2013 | 10/21/2013 | 10/21/2013 | P | PART |
Jim Sly
|
|
|
Shear insepction please-Tom Phone #: ###-#### Shear.....OK.
|
BLD-Foundation | 10/1/2013 | 10/2/2013 | 10/2/2013 | P | PASS |
Jim Sly
|
|
|
As early as possible Phone #: 2083534535 >> Inspection requested via mobile web by Tom Andrews
|
BLD-Foundation | 10/1/2013 | 10/1/2013 | 10/1/2013 | P | CANC |
Jim Sly
|
|
|
As early as possible Phone #: 2083534535 >> Inspection requested via mobile web by Tom Andrews Inspection cancelled via mobile web on Tuesday, October 01, 2013.
|
BLD-Footing | 9/27/2013 | 9/30/2013 | 9/30/2013 | P | PART |
Jim Sly
|
|
|
As early as possible Phone #: 2083534535 >> Inspection requested via mobile web by Tom Andrews Footing appears OK....Pending MTI soils and rebar approval..........Special insp, tests and approvals.
|
Issue PAID IN FULL permit | | | 9/10/2013 | | DONE |
Christina Prado
|
|
|
|
Print Occupancy Form | | | 9/9/2013 | | DONE |
Barbara Stitt
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/3/2013 | | DONE |
John Menard
|
|
|
|
Print Occupancy Form | | | 9/3/2013 | | DONE |
Christina Prado
|
|
|
|
Permit Ready to Issue | | | 9/3/2013 | | |
|
|
|
|
Telephone call | | | 9/3/2013 | | |
|
|
|
9-3-13 called left message permit ready and fee given / Also need ACHD,GC,RP ///dld
|
Routing - PLAN CHECK | 8/19/2013 | | 9/3/2013 | | PASS |
John Menard
|
|
|
|
Plan assigned to (JCM) | 7/23/2013 | | 9/3/2013 | | PASS |
John Menard
|
|
|
1st Review Complete 8-15-2013
|
Plan resubmittals received | | | 8/30/2013 | | DONE |
Tisha Gallop
|
|
|
receieved response and plan sheets A1, A2; inserted by arch. rep. and taken back to John Menard.
|
Plan resubmittals requested | | | 8/29/2013 | | DONE |
John Menard
|
|
|
E-mailed the architect a request for additional revisions. JCM
|
Plan Reviewer's activity | | | 8/29/2013 | | PASS |
John Menard
|
|
|
Reviewed and approved structural revisions. JCM
|
Plan resubmittals received | | | 8/27/2013 | | DONE |
|
|
|
rec'd two copies of response letter, calcs, and sheets A1; A2; A5; A6; A7; A8; A9 - inserted and taken to jcm
|
Routing - FIRE | 8/15/2013 | 8/15/2013 | 8/19/2013 | | PASS |
Scott Arellano
|
|
|
Attached IFC Comments to plans.
|
1st review completed | | | 8/19/2013 | | FAIL |
|
|
|
Failed plan check and structural reviews.
|
Route to Impact Fee Review | 8/15/2013 | 8/20/2013 | 8/16/2013 | | PASS |
Cindy M. Gould
|
|
|
|
Plan resubmittals requested | | | 8/15/2013 | | DONE |
John Menard
|
|
|
E-mailed the architect a copy of plan review requesting revisions. JCM
|
Routing - PLAN CHECK | 8/2/2013 | | 8/15/2013 | | FAIL |
John Menard
|
|
|
|
Route to Impact Fee Review | 7/23/2013 | 7/26/2013 | 8/14/2013 | | PASS |
Cindy M. Gould
|
|
|
|
Routing Off Site - STRUCTURAL | 7/25/2013 | | 8/5/2013 | | FAIL |
John Menard
|
|
|
|
Plan resubmittals requested | | | 8/5/2013 | | DONE |
John Menard
|
|
|
E-mailed the architect a copy of the structural review requesting revisions. JCM
|
Routing - PLANNING | 8/1/2013 | | 8/2/2013 | | PASS |
Sarah Schafer
|
|
|
Approved per DRH13-00201.
|
Routing - PLUMBING | 7/26/2013 | | 8/1/2013 | | PASS |
Daryl Spivey
|
|
|
Provide tempered water to public lavs.
Per plan and 2009 ISPC.
|
Routing - PUBLIC WORKS | 7/24/2013 | | 7/26/2013 | | PASS |
John Menard
|
|
|
|
Routing - Erosion and Sediment | 7/25/2013 | | 7/26/2013 | | PASS |
Kimberly M. Johnson
|
|
|
|
Routing PW Sewer Rating | | | 7/25/2013 | | PASS |
Connie Baumgartner
|
|
|
|
Routing PW Solid Waste | 7/24/2013 | | 7/25/2013 | | PASS |
Peter J. McCullough
|
|
|
|
Routing PW Drainage | 7/24/2013 | | 7/24/2013 | | PASS |
Brian Murphy
|
|
|
|
Routing - Addressing | 7/23/2013 | | 7/24/2013 | | PASS |
Jason C. Taylor
|
|
|
|
Application received | | 7/22/2013 | 7/23/2013 | | DONE |
|
|
|
|
Routing - PLANNING Land Div | 7/23/2013 | | 7/23/2013 | | PASS |
Dave Abo
|
|
|
Lot 7, Block 1 of Greenfield Park Subdivision.
|
Pending Assignment by JCM | 7/23/2013 | | 7/23/2013 | | DONE |
John Menard
|
|
|
|
Intake Approval | | | 7/22/2013 | | PASS |
Sam Zahorka
|
|
|
Intake approved under PRE13-00154
|
Plans ACCEPTED BY PLAN TECH | | | 7/22/2013 | | DONE |
Tisha Gallop
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 7/22/2013 | | DONE |
Tisha Gallop
|
|
|
|