Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD13-02538
StatusFinaled
Name PRIMARY CONSTRUCTION INC
Site Address 601 W FRONT ST
Project NamePanda Express
Customer Number 
ePlanReviewYes
Description
(PANDA EXPRESS) - *** 11-27-13 PLAN MODIFICATION TO INCLUDE: EXTERIOR UMBRELLA, KITCHEN & RESTROOM LAYOUT CHANGES DUE TO NEW FIRE RISER LOCATION; ADDED ADDITIONAL LIGHTING FIXTURE IN EACH RESTROOM ** SRZ. To build-out for the first time a 2,002 square foot tenant space for use by a restaurant in an existing shell building constructed under BLD13-00730. Work to include: new concrete slab floor; construction of interior nonbearing walls to create: Dining room, kitchen, kitchen prep. room, serving area, and two fully accessible restrooms for men/women; install a gypsum ceiling; install a walk-in cooler and walk-in freezer; related interior finishes in compliance with chapter 8 of the 2009 IBC; new light fixtures and plumbing fixtures; install a new HVAC unit and duct work; intstall new Type I hoods; and relocate an existing door and modify an existing storefront at the South elevation. All work per the approved plans, red-lined comments, and conditions of all reviewing agencies for this project. Energy code compliance for the envelope was part of the SHELL permit. A Certificate of Occupancy with the occupant load total is required to be obtained after all work has been inspected and approved and prior to tenant occupying this space. NOTE: This building is fully fire sprinklered and has an approved alarm system. ANY ALTERATIONS TO THE SPRINKLER SYSTEM WILL REQUIRE A SEPARATE PERMIT, and shall be installed per NFPA #13 as regulated by the fire department. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 2/7/20142/19/2014 DONE
DetailsChristina Prado
completed 2-19-14
First Notice 1/5/20141/28/2014 DONE
Zoning Approval12/26/201312/26/201312/26/2013 PASS
DetailsSarah Schafer
Permanent Occupancy  12/26/2013 DONE
DetailsBarbara Stitt
FIRE-Final Inspection12/20/201312/20/201312/20/2013PPASS
DetailsForrest France
Fire life safety passed.
BLD-Final12/19/201312/20/201312/20/2013PPASS
DetailsDave Hannah
gary Phone #: ###-####
FIRE-Conference12/18/201312/18/201312/18/2013PDONE
DetailsForrest France
On site conference with contractor regarding project related fire sprinkler and hood suppression system work.
BLD-Ceiling Grid Inspection12/17/201312/17/201312/17/2013PPASS
DetailsDave Hannah
GARY Phone #: ###-####
Plan assigned to (SRZ)11/26/201311/26/201311/27/2013 PASS
DetailsSam Zahorka
Panda Express - Plan Modification ePlanReview
Print Occupancy Form  11/27/2013 DONE
DetailsChristina Prado
CHANGE STATUS TO (ISS)  11/27/2013 DONE
DetailsChristina Prado
Routing - PLAN CHECK11/26/2013 11/27/2013 PASS
DetailsSam Zahorka
Plan modification - umbrella structure at outdoor patio
Plan Modification Accepted  11/26/2013 DONE
DetailsTisha Gallop
plan modification started in ePlanReview for the structural engineering for the outdoor umbrella
CHANGE STATUS TO (ISS)  11/21/2013 DONE
DetailsChristina Prado
Print Occupancy Form  11/21/2013 DONE
DetailsChristina Prado
Plan assigned to (SRZ)11/12/201311/12/201311/20/2013 PASS
DetailsSam Zahorka
Pending Fire and Plumbing to PASS. (Panda Express) - Plan Modification
Routing - PLAN CHECK11/20/2013 11/20/2013 PASS
DetailsJason Blais
For Sam Zahorka. Plan Mod fees form uploaded into ePlanReview under Agency Comments.
Routing - FIRE11/14/201311/14/201311/19/2013 PASS
DetailsScott Arellano
See Fire Report Revision 1
Routing - PLUMBING11/14/2013 11/19/2013 PASS
DetailsBill VanDegrift
1. DCVA on water service not to be installed more than 5 feet above floor.
2. RPBP required for soda machine.
3. Ice maker may require an DCVA if not air gapped.
4. RPBP required on chemical feeder if not air gapped.
5. Tempered water required at public handwash sinks.
6. Additional backflow protection may be required on installed equipment.
Routing PW Environmental11/14/2013 11/15/2013 PASS
DetailsWalt Baumgartner
Routing - PUBLIC WORKS11/14/2013 11/14/2013 PASS
DetailsBeverly Mountain
Routing Off Site - C.D.H11/14/2013 11/14/2013 PASS
DetailsJason Blais
Approved by Brigitta Gruenberg of CDHD in ePlanReview.
Routing PW Sewer Rating11/14/2013 11/14/2013 PASS
DetailsConnie Baumgartner
Routing - Addressing11/14/2013 11/14/2013 PASS
DetailsEmily Dixon
Routing - PUBLIC WORKS11/14/2013 11/14/2013 PASS
DetailsBeverly Mountain
Routing - PLAN CHECK11/14/2013 11/14/2013 PASS
DetailsSam Zahorka
Plan Modification Accepted  11/12/2013 DONE
DetailsChristina Prado
request rec'd for plan mod per Angie B
Issue PAID IN FULL permit  11/8/2013 DONE
DetailsBarbara Stitt
Print Occupancy Form  11/8/2013 DONE
DetailsBarbara Stitt
Plan assigned to (SRZ)9/24/20139/24/201310/22/2013 PASS
DetailsSam Zahorka
2nd Review completed. 10/21/13 - 1st review completed. Level 3 TI - Panda Express
Permit Ready to Issue  10/22/2013 DONE
DetailsBarbara Stitt
Routing - PLAN CHECK10/21/2013 10/22/2013 PASS
DetailsSam Zahorka
PLANS/APPL TAKEN TO FRONT DESK  10/22/2013 DONE
DetailsSam Zahorka
Routing - PLAN CHECK10/21/2013 10/21/2013 FAIL
DetailsSam Zahorka
Called the architect and discussed the two last corrections.
1st review completed  10/10/2013 DONE
DetailsSam Zahorka
Routing - PLAN CHECK9/24/2013 10/10/2013 FAIL
DetailsSam Zahorka
Routing Off Site - C.D.H9/24/2013 10/10/2013 PASS
DetailsSam Zahorka
Routing - FIRE9/24/20139/24/20139/30/2013 PASS
DetailsCraig D. Hanson
Routing PW Solid Waste9/24/2013 9/26/2013 PASS
DetailsPeter J. McCullough
Routing PW Sewer Rating9/24/2013 9/25/2013 PASS
DetailsConnie Baumgartner
Routing PW Environmental9/24/2013 9/25/2013 PASS
DetailsWalt Baumgartner
GI in place as part of shell & core, OK
Routing - Design Review9/24/2013 9/25/2013 PASS
DetailsSarah Schafer
Sarah Schafer - DRH13-00284 Approved.
Routing - PLUMBING9/24/2013 9/25/2013 PASS
DetailsBill VanDegrift
1. Provide DCVA on water service to bld.
2. Require a RPBP on Kay chemical feed system.
3. Install per ISPC.
Routing - Addressing9/24/2013 9/24/2013 PASS
DetailsEmily Dixon
Routing - PUBLIC WORKS9/24/2013 9/24/2013 PASS
DetailsBeverly Mountain
Plan Reviewer's activity  9/24/2013 DONE
DetailsJason Blais
Emailed contact to have her contact ACHD for evaluation of any additional impact fees are due. Written verification from ACHD needs to be provided to our Permit Counter prior to the building permit being issued.
Intake Approval  9/24/2013 PASS
DetailsJohn Menard
Pending Assignment by JCB9/24/2013 9/24/2013 DONE
DetailsJason Blais
Intake Approval  9/18/2013 FAIL
DetailsJohn Menard
Plan sheeet M600 was submitted; however, the Heating and Cooling load calculations were not included on that sheet. Please submit the required Heating and Cooling load calculations for this project. JCM
Intake Approval  9/17/2013 FAIL
DetailsJohn Menard
The submittal checklist indicates that the required Mechanical Comcheck energy compliance and the Heating and Cooling load calculations were submitted on plan sheet M600; however, it does not appear that plan sheet M600 was uploaded. Please upload plan sheet M600 with the required mechanical energy and load calculations. JCM
Intake Approval  9/16/2013 FAIL
DetailsJohn Menard
The permit application is not complete. Please complete a plan intake checklist for a level 3, major tenant improvement project. Please upload the completed checklist along with all of the applicable items required on the checklist. JCM
Payment Received  9/14/2013 DONE
Payment received via Govolutions
Application received  9/14/2013 DONE
Application submitted via PDS Online on Sep 14 2013 6:32PM