Permit Information
Permit NumberBLD13-02706
StatusFinaled
Name AOI CORPORATION
Site Address 1001 E PARKCENTER BLVD
Project NameGORDMANS STORE #122
Customer Number 
ePlanReviewYes
Description
(GORDMANS STORE #122) The fire sprinkler system is used for unlimited area of the building and for fire area. To prepare an existing 49,861 square foot tenant space for a new retail sales tenant. Permit BLD13-02316 was issued earlier to allow interior non-structural demolition and to allow the construction of an interior tenant demising wall to create this tenant space from a larger space. Work is to include 2 upgraded restrooms to be accessible to the disabled, interior nonbearing walls, 2 new double leaf exit doors including headers and landings, alterations to the roof to support roof top HVAC units, a loading dock, a ramp at the loading dock, guards on both sides of the loading ramp, added roof insulation for a total of R-20, mechanically fastened membrane roof covering, new exterior walls and parapets at the entry, interior finishes, wall furring and cavity insulation at some exterior walls, and interior display shelves. An elevated floor level (about 49 inches above the main level) having a floor area of about 176 square feet and a stairway to serve it will be constructed. Special Inspection is required for steel (including welding), concrete, masonry, soils, epoxy anchors, expansion anchors, and EIFS. A separate permit is required for free-standing display racks and shelving units exceeding 8 feet in height. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  1/6/2016 DONE
First Notice 3/24/20143/31/2014 DONE
DetailsChristina Prado
mailed 4-1-14
BLD-Final3/12/20143/14/20143/14/2014APASS
DetailsJim Storey
Bob Phone #: ###-####
Permanent Occupancy  3/14/2014 DONE
FIRE-Final Inspection3/4/20143/4/20143/4/2014PPASS
DetailsForrest France
Fire life safety inspection completed. Previous correction items finished.
FIRE-Final Inspection2/21/20142/24/20142/27/2014PPASS
DetailsCraig D. Hanson
no corrections
BLD-Framing/Rough-in1/21/20141/22/20141/22/2014PPASS
DetailsTony Young
Kyle Phone #: ###-####,, front stair area
BLD-Framing/Rough-in1/13/20141/14/20141/14/2014PPASS
DetailsJim Storey
Kyle Phone #: ###-#### exterior front ok to sheet/ rfi for paripet pending/ hard lid ok to cover storage rm.
BLD-Footing12/18/201312/19/201312/19/2013APART
DetailsMike Jordan
kyle Phone #: ###-####. Loading dock footing and grade beam footing at main entry. Pending special inspection. Also went over cold weather conc. with contractor.
BLD-Framing/Rough-in12/18/201312/19/201312/19/2013APASS
DetailsMike Jordan
kyle Phone #: ###-####. Interior steel stud framed walls (I walls) non moveable ok.
BLD-Framing/Rough-in12/5/201312/6/201312/6/2013APART
DetailsJim Storey
kyle Phone #: ###-#### exterior wall insulation ok/ pending movable wall engineering submital to planreview.
BLD-Framing/Rough-in11/21/201311/22/201311/22/2013PPASS
DetailsJim Storey
Kyle Phone #: ###-#### back and west walls ok/ dressing rms and office and storage areas ok.
Permit Ready to Issue  11/15/2013 DONE
DetailsTisha Gallop
Issue PAID IN FULL permit  11/15/2013 DONE
DetailsChristina Prado
Print Occupancy Form  11/15/2013 DONE
DetailsChristina Prado
Plan assigned to (CJW)10/7/201310/7/201311/14/2013 PASS
DetailsCarl Westfall
GORDMANS ePlanReview - Level 3 TI - (20 days - Nov 1)
Routing - Erosion and Sediment11/8/2013 11/14/2013 PASS
DetailsEvan Jenkins
Recently add-on of full ESC Narrative and Site Map Approved
PLANS/APPL TAKEN TO FRONT DESK  11/14/2013 DONE
Routing - FIRE11/8/2013 11/12/2013 PASS
DetailsCraig D. Hanson
See report
Routing - PLAN CHECK11/7/2013 11/8/2013 PASS
DetailsCarl Westfall
Drawings approved after resubmittal review
Plan resubmittals received  11/7/2013 DONE
Plan resubmittals requested  11/2/2013 DONE
1st review completed  11/1/2013 DONE
Routing - PLAN CHECK10/7/2013 11/1/2013 FAIL
DetailsCarl Westfall
Plan review delayed because of multiple resubmitals for other projects and because of office being tore up for furniture replacement.
Routing - FIRE10/7/201310/7/201310/14/2013 FAIL
DetailsCraig D. Hanson
Preliminary review done, no report until building plan check complete.
Routing - Erosion and Sediment10/7/2013 10/8/2013 FAIL
DetailsEvan Jenkins
ESC Waiver Denied:
Submit Full ESC Plan and Narrative
Routing - PLUMBING10/7/2013 10/8/2013 PASS
DetailsBill VanDegrift
per plans and ISPC
Routing PW Sewer Rating10/7/2013 10/8/2013 PASS
DetailsConnie Baumgartner
Payment Received  10/7/2013 DONE
Payment received via Govolutions
Pending Assignment by JCB10/7/2013 10/7/2013 DONE
DetailsJason Blais
Routing - Addressing10/7/2013 10/7/2013 PASS
DetailsEmily Dixon
Routing - PUBLIC WORKS10/7/2013 10/7/2013 PASS
DetailsBeverly Mountain
Intake Approval  10/7/2013 PASS
DetailsJohn Menard
Prescreen passed on 10/3/13 by John Menard. Plan Review Fees paid on 10/7/13.
Intake Approval  10/3/2013 FAIL
DetailsJohn Menard
1. The energy ComCheck compliance sheete are required to be submitted on plan sheets. Please copy the Comcheck compliance sheets to plan sheets.

2. Please revise the door and window schedule to include the U-Factors and SHGC for any proposed new exterior windows or doors.
Application received  10/2/2013 DONE
Application submitted via PDS Online on Oct 2 2013 8:45AM