Permit Information
Permit NumberBLD13-02969
StatusFinaled
Name RA SCHULTZ AND COMPANY
Site Address 7709 W OVERLAND RD Unit: 100
Project NameToni & Guy Hairdressing
Customer Number 
ePlanReviewYes
Description
(TONI & GUY HAIRDRESSING ACADEMY - BUILDING B - SUITE 110) Remodel changing occupancy from assembly use to a new professional hairdressing academy in a 9,489 square foot existing tenant suite. Work to include: Demolition works per plans; construct new interior walls with bracing and glass wall systems to create new offices, student lounge, staff break room, classrooms, open work station rooms, storage rooms, laundry room, janitor room, and waxing room; new structural steel ceiling in select locations per plans; new suspended acoustical tile ceiling system installed per CISCA guideline; related interior finishes in compliance with chapter 8 of the 2009 IBC; and plumbing, electrical work. All work per the approved plans, attached plan review report, and all other reviewing agencies approvals. A new Certificate of Occupancy with the new occupant load total is required to be obtained after all work has been inspected and approved and prior to tenant occupying this space. NOTE: This building is fully fire sprinklered for area increase and 1-hr substitution. Any alterations or modifications to the fire sprinkler system shall be per NFPA #13 as regulated by the fire department and will require a separate permit. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 5/17/20145/22/2014 DONE
This permit finaled on the web by Richard Schultz
First Notice 4/20/20145/7/2014 DONE
DetailsBarbara Stitt
Faxed 5-7-14
Permanent Occupancy  4/10/2014 DONE
DetailsChristina Prado
BLD-Final4/8/20144/8/20144/8/2014PPASS
DetailsMike Jordan
Thanks Matt, Phone #: ###-#### >> Inspection requested via web by Richard Schultz. All issues resolved. ok for perm occ.
BLD-Final4/7/20144/7/20144/7/2014PFAIL
DetailsMike Jordan
Thanks Matt, Phone #: ###-#### >> Inspection requested via web by Richard Schultz. The exterior emregency lightingg at main exit is non functional.
BLD-Final4/3/20144/4/20144/4/2014ANR
DetailsMike Jordan
Matt Phone #: ###-####. Needs electrical and mech. finals.
FIRE-Final Inspection3/27/20143/27/20143/27/2014PPASS
DetailsTroy Cobbley
life safety passed
BLD-Ceiling Grid Inspection2/7/20142/10/20142/10/2014PPASS
DetailsMike Jordan
Thanks Matt, Phone #: ###-#### >> Inspection requested via web by Richard Schultz
BLD-Framing/Rough-in1/10/20141/10/20141/10/2014PPASS
DetailsMike Jordan
Holddowns on interior steel framed walls ok.
BLD-Framing/Rough-in1/9/20141/10/20141/10/2014ANR
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Richard Schultz. Moved to pm.
BLD-Framing/Rough-in1/9/20141/9/20141/9/2014PPASS
DetailsMike Jordan
Thanks Matt, Phone #: ###-#### >> Inspection requested via web by Richard Schultz. INterior steel stud framed walls adn hardlids ok. No grid at this time.
Case Summary (BLD)  1/2/2014 DONE
Issue PAID IN FULL permit  11/26/2013 DONE
DetailsChristina Prado
Print Occupancy Form  11/26/2013 DONE
DetailsChristina Prado
OVERRIDE  11/21/2013  
Permit Ready to Issue  11/21/2013 DONE
DetailsChristina Prado
Plan assigned to (SRZ)11/1/201311/1/201311/20/2013 PASS
DetailsSam Zahorka
1st review completed. (Toni & Guy Hairdressing Academy) Pending Fire and Plumbing to PASS.
PLANS/APPL TAKEN TO FRONT DESK  11/20/2013 PASS
DetailsJason Blais
For Sam Zahorka.
Routing - PLAN CHECK11/15/2013 11/20/2013 PASS
DetailsJason Blais
For Sam Zahorka.
Routing - FIRE11/15/201311/15/201311/19/2013 PASS
DetailsScott Arellano
See Fire Report Rev 1
1st review completed  11/15/2013 DONE
DetailsSam Zahorka
Failed Fire and Plumbing
Routing - PLUMBING11/15/2013 11/15/2013 PASS
DetailsBill VanDegrift
Hair sinks vents must be ran seperately over to wall and up 6 inches above flood level before tying together.
Delete recirc line if RPBP's are used.
Routing - PLAN CHECK11/1/2013 11/15/2013 PASS
DetailsSam Zahorka
Plan resubmittals received  11/15/2013 DONE
DetailsSam Zahorka
Routing - FIRE11/1/201311/1/201311/6/2013 FAIL
DetailsCraig D. Hanson
Minor corrections required. See report
Telephone call  11/6/2013 DONE
Spoke with Matt regarding possible HazMat in storage area. He will ask the tenant for inventory if necissary.
Routing - PLUMBING11/1/2013 11/5/2013 FAIL
DetailsBill VanDegrift
1) Use Idaho State Plumbing Code fixture sixing.(fixture schedule)
2) Combination waste and vent systems are approved for low usage fixtures where structural conditions will not allow conventional venting of fixtures. Vent each floor sink.
Routing - Erosion and Sediment11/1/2013 11/4/2013 PASS
DetailsEvan Jenkins
Routing PW Sewer Rating11/1/2013 11/1/2013 PASS
DetailsConnie Baumgartner
Intake Approval  11/1/2013 PASS
DetailsJason Blais
Prescreen passed by Adele Schaffeld-Griffin and plan review fees paid.
Pending Assignment by JCB11/1/2013 11/1/2013 DONE
DetailsJason Blais
Routing - Addressing11/1/2013 11/1/2013 PASS
DetailsEmily Dixon
Routing - PUBLIC WORKS11/1/2013 11/1/2013 PASS
DetailsBeverly Mountain
Intake Approval  10/28/2013 FAIL
DetailsAdele J Schaffeld-Griffin
Jason, here is what I sent Matt. I did find the energy information. He did not provide a com check just a compliance box in the corner of the reflective ceiling plan.

Matt,
1 Please complete and upload the ESC waiver letter.
2 Please re upload the deign professional of record document to read left to right.
3 The floor plan layout is only shown on the electrical sheets for the open workstation areas. The floor plan appears to be for hair stations only. Please let me know if this is correct, that there will be no nail stations, as the architectural floor plan does not include the layout.
4 I have spoken with Bill this morning and the plumbing plans will need to be designed and stamped by an engineer.

When the prescreen for this change in occupancy project is approved it will be routed as a major TI.

Please let me know if you have any questions.

Adele
Intake Approval  10/28/2013 FAIL
DetailsAdele J Schaffeld-Griffin
Matt,
1 I have spoken with Bill the plumbing plans will need to be designed and stamped by an engineer prior to approving the prescreen.

When the prescreen for this change in occupancy project is approved it will be routed as a major TI.

Please let me know if you have any questions.

Adele
Payment Received  10/23/2013 DONE
Payment received via Govolutions
Application received  10/23/2013 DONE
Application submitted via PDS Online on Oct 23 2013 5:04PM