DOC - Permit Finaled | 4/5/2019 | 4/5/2019 | 4/5/2019 | P | PASS |
Jim Storey
|
|
|
|
BLD-Final | 4/14/2014 | 4/15/2014 | 4/15/2014 | P | PASS |
Tom Arcoraci
|
|
|
Dean Phone #: ###-####
|
FIRE-Final Inspection | 4/10/2014 | 4/11/2014 | 4/11/2014 | A | PASS |
Forrest France
|
|
|
Verified noted items completed. Life safety inspection passed.
|
FIRE-Conference | 4/7/2014 | 4/8/2014 | 4/8/2014 | A | DONE |
Forrest France
|
|
|
On site conference regarding smoke alarm locations, portable fire extinguishers, premise identification, automatic door closures, and project schedule. Discussed approved plan and fire code review notes.
|
BLD-Framing/Rough-in | 4/7/2014 | 4/7/2014 | 4/7/2014 | P | PASS |
Tom Arcoraci
|
|
|
Dean Phone #: ###-####
|
BLD-Footing | 3/14/2014 | 3/14/2014 | 3/14/2014 | P | PASS |
Tom Arcoraci
|
|
|
Dean Phone #: ###-####
|
BLD-Framing/Rough-in | 1/29/2014 | 1/29/2014 | 1/29/2014 | P | PASS |
Tom Arcoraci
|
|
|
dean Phone #: ###-####
|
BLD-Conference | 1/27/2014 | 1/27/2014 | 1/27/2014 | P | PASS |
Tom Arcoraci
|
|
|
dean Phone #: ###-#### 1 5/8 x on ceiling ok per plan review
|
Permit Ready to Issue | | | 12/20/2013 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 12/20/2013 | | DONE |
|
|
|
|
Print Occupancy Form | | | 12/20/2013 | | DONE |
|
|
|
|
Plan assigned to (SRZ) | 11/26/2013 | 11/26/2013 | 12/17/2013 | | PASS |
Sam Zahorka
|
|
|
1st Review completed - ePlanReview Level 3 TI Fire Repair 4-plex
|
Routing - PLAN CHECK | 12/13/2013 | | 12/17/2013 | | PASS |
Sam Zahorka
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/17/2013 | | DONE |
Sam Zahorka
|
|
|
|
1st review completed | | | 12/13/2013 | | DONE |
Sam Zahorka
|
|
|
|
Routing - FIRE | 11/26/2013 | 11/26/2013 | 12/12/2013 | | PASS |
Craig D. Hanson
|
|
|
|
Routing - PLAN CHECK | 11/26/2013 | | 12/10/2013 | | FAIL |
Sam Zahorka
|
|
|
|
Routing - PLANNING | 11/26/2013 | | 12/4/2013 | | PASS |
Leon Letson
|
|
|
New carport must be setback a minimum of 5' from the rear property line.
|
Routing - PLUMBING | 11/26/2013 | | 12/4/2013 | | PASS |
Bill VanDegrift
|
|
|
No review required.
|
Routing - MECHANICAL | 11/26/2013 | | 12/2/2013 | | PASS |
Troy James
|
|
|
Talked to Architect and he said no new mechanical equipment or ducts being installed.
|
Routing - Addressing | 11/26/2013 | | 12/2/2013 | | PASS |
Emily Dixon
|
|
|
Units need to be numbers, not letters:
Unit C needs to change to 101
Unit D needs to change to 102
Unit B needs to change to 103
Unit A needs to change to 104
|
Routing - PUBLIC WORKS | 11/26/2013 | | 11/27/2013 | | PASS |
Beverly Mountain
|
|
|
|
Routing - Erosion and Sediment | 11/26/2013 | | 11/27/2013 | | PASS |
Evan Jenkins
|
|
|
|
Intake Approval | | | 11/26/2013 | | PASS |
Jason Blais
|
|
|
Prescreen passed by Carl Westfall on 11/22/13. Plan Review Fees paid on 11/26/13.
|
Pending Assignment by JCB | 11/26/2013 | | 11/26/2013 | | DONE |
Jason Blais
|
|
|
|
Application received | | | 11/21/2013 | | DONE |
|
|
|
Application submitted via PDS Online on Nov 21 2013 3:08PM
|
First Notice | 4/5/2019 | 4/5/2019 | | | |
Jim Storey
|
|
|
|