Permit Information
Permit NumberBLD13-03370
StatusFinaled
Name ELITE RETAIL SERVICES INC
Site Address 350 N MILWAUKEE ST Unit: 1070
Project NameBTS - #1068, 1069, 1070, 1072
Customer Number 
ePlanReviewNo
Description
(VICTORIA'S SECRET - Boise Towne Square Mall - space 1070) Permit for tenant improvements to an existing 8,952 sq. ft. tenant space increasing it to 10,970 sq. ft. with work to include the removal of interior finishes, interior nonbearing partition walls, suspended ceiling, the north storefront, restrooms, HVAC systems and one 1 hour tenant demising wall. New construction will include new interior nonbearing partition walls, new HVAC systems, suspended ceilings, storefront, accessible restroom, lighting and a new tenant demising wall. The door to the mall service corridor is also being relocated and the service corridor wall is being alcoved at the new door location. This building is fully fire sprinklered and shall comply with NFPA 13 as regulated by the Fire Department. The smoke evacuation system is also required to be maintained. All work per the apporved plans. CDM
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 8/31/20149/19/2014 DONE
This permit finaled on the web by Stephanie Carroll
Second Notice 7/25/20148/26/2014 DONE
First Notice 7/7/20147/15/2014 DONE
Faxed 7-15-14
Permanent Occupancy  6/27/2014 DONE
DetailsTisha Gallop
BLD-Final6/26/20146/26/20146/26/2014PPASS
DetailsMike Jordan
All issues resolved. Ok for perm occ.
BLD-Final6/25/20146/26/20146/26/2014AFAIL
DetailsMike Jordan
TJ Phone #: ###-####. Needs to provide compliant door hardware for managers office and conferance rm.
FIRE-Final Inspection6/24/20146/25/20146/25/2014PPASS
DetailsForrest France
Noted corrections completed. Fire life safety finaled.
FIRE-Final Inspection6/23/20146/24/20146/24/2014PFAIL
DetailsTroy Cobbley
Provide additional smoke detector at the new exit into the mall corridor for the smoke evac system or have the mall engineer approve current setup. Need racking permit scheduled for inspection.
BLD-Framing/Rough-in4/28/20144/28/20144/28/2014PPART
DetailsMike Jordan
ceiling framing partial // CJ Phone #: ###-####. hardlids ok to cover pending ele. r.i. inspection.
BLD-Framing/Rough-in4/22/20144/22/20144/22/2014PPASS
DetailsMike Jordan
TJ Phone #: ###-####. Interior steel stud walls and soffit at front of store an store fronts.
BLD-Framing/Rough-in4/10/20144/11/20144/11/2014APASS
DetailsMike Jordan
c.j. - wall framing Phone #: ###-####. Irior steel stud walls, furred walls and pass throughs from back of house to 2nd column line ok. Hardlids at back house ok pending other trades.
BLD-Framing/Rough-in4/4/20144/7/20144/7/2014APART
DetailsMike Jordan
TJ Phone #: ###-####. Interior steel stud framed walls at back of house only, non sales area or fitting rooms.
Plan assigned to (CDM)12/5/201312/5/20132/21/2014 PASS
DetailsCarl D Madsen
Routing - PLAN CHECK2/21/2014 2/21/2014 PASS
DetailsCarl D Madsen
PLANS/APPL TAKEN TO FRONT DESK  2/21/2014 DONE
Case Summary (BLD)  2/21/2014 DONE
Print Occupancy Form  2/21/2014 DONE
DetailsChristina Prado
Permit Ready to Issue  2/21/2014 DONE
Telephone call  2/21/2014 DONE
spoke with Tim, need GC fees due
Issue PAID IN FULL permit  2/21/2014 DONE
Plan resubmittals received  2/19/2014 DONE
DetailsChristina Prado
received one transmittal letter as well as two sets revised plan sheets marked A00.00, A00.02, A08.01, A08.02, A08.03, A08.05, A08.07, A08.10A, A08.10B, A08.11B, A08.15, A08.20, S02.01 & S02.02;Plans taken to carl Madsen for further review
Routing - PLAN CHECK12/26/2013 1/28/2014 FAIL
DetailsCarl D Madsen
Sent second plan review report and called Francis at McCall design 1-28-14 CDM
Plan resubmittals received  1/17/2014 DONE
DetailsChristina Prado
received one copy of response letter, two copies of mall approval, one transmittal sheet and two sets of revised plans marked A00.00, A00.02, A08-01, A08.02, A08.03, A08.05, A08.07, A08.10A, A08.10B, A08.11A, A08.11B, A08.15, A08.20 and 4 copies of revised plan sheets marked EN01.01; Plans taken to Carl Madsen for further review
Routing - FIRE12/24/201312/24/201312/26/2013 PASS
DetailsCraig D. Hanson
1st review completed  12/26/2013 FAIL
Failed Plan Check
Routing - PLAN CHECK12/5/2013 12/24/2013 FAIL
DetailsCarl D Madsen
E-mailed plan review repot to the architect.
Routing - PUBLIC WORKS12/5/2013 12/6/2013 PASS
DetailsConnie Baumgartner
Routing - Addressing12/6/2013 12/6/2013 PASS
DetailsJason C. Taylor
Routing PW Sewer Rating12/6/2013 12/6/2013 PASS
DetailsConnie Baumgartner
Application received 12/5/201312/5/2013 DONE
Plans ACCEPTED BY PLAN TECH  12/5/2013 DONE
DetailsTisha Gallop
Recd Pcfee & Taken To Pln CK  12/5/2013 DONE
DetailsTisha Gallop