Information based on query as of Wednesday, August 14, 2024.
Permit Information
Permit NumberBLD14-00342
StatusFinaled
Name CSDI CONSTRUCTION INC
Site Address 4720 N 36TH ST
Project NameQuail Hollow Clubhouse Remodel
Customer Number 
ePlanReviewYes
Description
(QUAIL HOLLOW CLUBHOUSE)This property was annexed in to the City of Boise in 1982. The building was built in 1988. This permit is to remodel the upper level to relocate the pro-shop from the main level to the upper lever. The lower level will be left as is shown on the demo permit for future work to be permitted separately. The upper lever will include minor demo per plans. The existing windows and doors will have structural modifications; the 2 restrooms will be remolded. The kitchen, seating area, food service area will be renovated per approved plans. A new hi/low drinking fountain will be installed. All interior finish material shall meet the requirements of chapter 8 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **ajs**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice 9/5/20149/23/2014 DONE
DetailsChristina Prado
completed 9-23-14
Print Statement  9/23/2014 DONE
DetailsChristina Prado
First Notice 8/16/20148/26/2014 DONE
BLD-Conference8/5/20148/6/20148/6/2014ADEFR
DetailsTony Young
Jeffrey Phone #: ###-####,, address issue,, verify correct ,,, office to handle internally
BLD-Final8/5/20148/6/20148/6/2014ADONE
DetailsTony Young
Jeffrey Phone #: ###-####,, office to handle address issue
Permanent Occupancy  8/6/2014 DONE
DetailsChristina Prado
BLD-Final8/4/20148/5/20148/5/2014PPASS
DetailsTony Young
Jeffrey Phone #: ###-####
FIRE-Final Inspection8/4/20148/5/20148/5/2014APASS
DetailsTroy Cobbley
Life safety passed per Craig Hansen
BLD-Conference7/24/20147/24/20147/24/2014PPEND
DetailsTony Young
Mike Phone #: ###-####,, walk through for final,, need proper address,, f/l/s
BLD-Final7/18/20147/22/20147/22/2014ACANC
DetailsTony Young
Mike Phone #: ###-####
FIRE-Final Inspection7/18/20147/21/20147/21/2014PFAIL
DetailsCraig D. Hanson
No fire plan review done. Work on hood suppression system done without permit. Hood system not tied into Fire Alarm sytem, permit needed. No Fire Life Safety inspection can be preformed until a hood suppresion permit and fire alarm permit has been issued and finaled. CDH 07/21/14
BLD-Framing/Rough-in6/11/20146/13/20146/13/2014PPASS
DetailsTony Young
mike Phone #: ###-####
FIRE-Conference5/29/20145/29/20145/29/2014PDONE
DetailsForrest France
Discussion with contractor regarding fire sprinkler work, existing cooking hood, scope of remodel, etc.
BLD-Framing/Rough-in5/27/20145/27/20145/27/2014PNR
DetailsJim Storey
Mike Phone #: ###-####
Permit Ready to Issue  4/22/2014 DONE
DetailsBarbara Stitt
Issue PAID IN FULL permit  4/22/2014 DONE
DetailsBarbara Stitt
Print Occupancy Form  4/22/2014 DONE
DetailsBarbara Stitt
Plan assigned to (AJS)3/3/20143/3/20143/27/2014 PASS
DetailsAdele J Schaffeld-Griffin
1st review completed Due 3/14 Quale Hollow Clubhouse remodel
Routing - PLAN CHECK3/27/2014 3/27/2014 PASS
DetailsAdele J Schaffeld-Griffin
PLANS/APPL TAKEN TO FRONT DESK  3/27/2014 DONE
Routing - PLAN CHECK3/26/2014 3/26/2014 FAIL
DetailsAdele J Schaffeld-Griffin
see change marks in e plan
Routing - PLAN CHECK3/3/2014 3/14/2014 FAIL
DetailsAdele J Schaffeld-Griffin
see change marks in e plan.
Routing - PUBLIC WORKS3/3/2014 3/14/2014 PASS
DetailsConnie Baumgartner
approved in e plan
Routing - Design Review3/3/2014 3/14/2014 PASS
DetailsSarah Schafer
approved in e plan
Routing - PLUMBING3/14/2014 3/14/2014 PASS
DetailsBill VanDegrift
1)kitchen prep sink changed and relocated to hand sink see A2.22) 120 deg. max hot water to lavs and hand sinks
Routing - MECHANICAL3/14/2014 3/14/2014 PASS
DetailsTroy James
1st review completed  3/14/2014 FAIL
DetailsAdele J Schaffeld-Griffin
Routing PW Environmental3/3/2014 3/3/2014 PASS
DetailsWalt Baumgartner
existing grease trap located lowest level golf cart storage area
Routing - Addressing3/3/2014 3/3/2014 PASS
DetailsEmily Dixon
Intake Approval  3/3/2014 PASS
DetailsAdele J Schaffeld-Griffin
Application received  2/18/2014 DONE
Application submitted via PDS Online on Feb 18 2014 12:05PM