BLD-Final | 1/9/2015 | 1/12/2015 | 1/12/2015 | A | PASS |
Phil Shearer
|
|
|
Mike Phone #: ###-####
|
Permanent Occupancy | | | 1/12/2015 | | DONE |
|
|
|
|
Print Occupancy Form | | | 1/12/2015 | | DONE |
Candy A. Nichols
|
|
|
|
Print Occupancy Form | | | 1/12/2015 | | DONE |
Candy A. Nichols
|
|
|
|
BLD-Foundation | 6/16/2014 | 6/17/2014 | 6/17/2014 | A | PASS |
Tom Arcoraci
|
|
|
Christian Phone #: ###-####
|
Issue PAID IN FULL permit | | | 5/16/2014 | | DONE |
Christina Prado
|
|
|
|
Plan assigned to (CJW) | 4/21/2014 | 4/21/2014 | 5/14/2014 | | PASS |
Carl Westfall
|
|
|
WINGS CENTER POOL - Level 3 TI (15 days - May 8)
|
Routing - PLAN CHECK | 5/12/2014 | | 5/14/2014 | | DONE |
Carl Westfall
|
|
|
Routing completed
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/14/2014 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 5/14/2014 | | DONE |
Barbara Stitt
|
|
|
|
Inspection Record Card- Bld | | | 5/14/2014 | | DONE |
Barbara Stitt
|
|
|
|
Telephone call | | | 5/14/2014 | | DONE |
Christina Prado
|
|
|
called jamie to advise permit is ready for pick and gave fees due
|
Routing - PLUMBING | 5/7/2014 | | 5/12/2014 | | PASS |
Daryl Spivey
|
|
|
Per plan and ISPC>
|
Routing - PLAN CHECK | 5/6/2014 | | 5/7/2014 | | DONE |
Carl Westfall
|
|
|
(5-6-14) Waiting for Plumbing to call the plans back.
(5-7-14) Resubmittals received. Routed back to plumbing.
|
Plan resubmittals received | | | 5/7/2014 | | DONE |
Christina Prado
|
|
|
Received two revised sets of plans marked P-1 & P-2; plans inserted by rep and taken back to Carl Westfall for review
|
Routing - FIRE | 5/5/2014 | | 5/6/2014 | | PASS |
Craig D. Hanson
|
|
|
No Report
|
1st review completed | | | 5/6/2014 | | DONE |
|
|
|
Failed plumbing
|
Routing - PLAN CHECK | 4/24/2014 | | 5/6/2014 | | PASS |
Carl Westfall
|
|
|
Drawings approved with "red lines".
|
Routing - Design Review | 4/23/2014 | | 4/24/2014 | | PASS |
Josh Wilson
|
|
|
Josh Wilson - DRH14-00133
|
Routing - PLUMBING | 4/22/2014 | | 4/23/2014 | | FAIL |
Bill VanDegrift
|
|
|
1. Page A 2.1 does not match P-1.
2. RPBP required on pool equipment makeup water.
3. Deck drain cannot directly drain to sanitary sewer. Pool drains to be indirectly wasted only.
|
Routing - Erosion and Sediment | 4/21/2014 | | 4/22/2014 | | PASS |
Andy J. Long
|
|
|
Reference ESC14-00093. Previously issued for pool excavation/shell by TK Construction. Fees added to transfer permit and RP for Pristine Pools and allow plan waiver so the $78.75 waiver and modification fee was added to permit fees of ESC14-00093. AJL
|
Routing - Addressing | 4/21/2014 | | 4/21/2014 | | PASS |
Jason C. Taylor
|
|
|
|
Routing - PUBLIC WORKS | 4/21/2014 | | 4/21/2014 | | PASS |
|
|
|
|
Pending Assignment by JCB | 4/18/2014 | | 4/21/2014 | | DONE |
Jason Blais
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 4/18/2014 | | |
|
|
|
|
Intake Approval | | | 4/18/2014 | | PASS |
Jason Blais
|
|
|
Prescreen passed by plans examiner and plan review fees paid.
|
Application received | | 3/28/2014 | 3/28/2014 | | DONE |
Tisha Gallop
|
|
|
|
Plan Reviewer's activity | | | 3/28/2014 | | DONE |
Adele J Schaffeld-Griffin
|
|
|
email sent to Jamie 3/28/14
Jamie,
I have attached the check list that was scanned in from the pool intake, sorry the items that I highlighted for you are dark in the scan. I have discovered that you will need to provide some additional information than noted on this check list. The only permits that are submitted are the grading, demo and a shell only.
We have not received a tenant improvement permit and plan set. In addition to the highlighted items all of the information on the check list that you have indicated “by GC” will need to be provided with your submittal in order for us to accept it, or you have the option of submitting after the architect has submitted the tenant improvement to address the code required information.
Sorry for the confusion but the information needed to make a complete submittal has not been received as you indicated.
Adele Schaffeld-Griffin
Plans Examiner II
City of Boise PDS
###-####
|
Intake Approval | | | 3/28/2014 | | FAIL |
Adele J Schaffeld-Griffin
|
|
|
see check list and email in plan reviewer activity for items needed
|
First Notice | | 1/22/2015 | | | |
|
|
|
|