Permit Information
Permit NumberBLD14-02038
StatusFinaled
Name BRUNO BUILT INC
Site Address 5947 E MILLET DR
Project NameHinman Residence
Customer Number 
ePlanReviewYes
Description
***Modification to Portal Frames see engineering in documents***WUI Zone B, Class A Roof, Permit for the construction of a new 4698 sq. ft., single story with unfinished basement (below grade unfinished basement 2453 sq. ft., grade level 2453 sq. ft.) single family dwelling with 3 bedrooms, 2complete bathrooms, 1 unfinished bathroom, approximately 740 sq. ft. of covered patio/porch and a 777 sq. ft. attached garage per the approved plans, plan review report and any notations. A-1 zoning and setbacks per planning. JG A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at 384-3946

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at 384-3946.

Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/27/20154/28/20154/28/2015PPASS
DetailsPhil Shearer
Jeremy Phone #: ###-####// please call 45min prior
DOC - Permit Finaled4/28/20154/28/20154/28/2015PPASS
DetailsPhil Shearer
PubWorks Occupancy Approval4/22/20154/22/20154/22/2015 DONE
DetailsJason C. Taylor
A letter from the applicant’s civil engineer indicating that the final grading and drainage is acceptable has been received by Public Works. Final occupancy may be approved by the building department. Jason Taylor ###-####.
BLD-Energy code compliance2/13/20152/17/20152/17/2015APASS
DetailsMike Jordan
Jeremy Phone #: ###-####
BLD-Framing/Rough-in2/12/20152/13/20152/13/2015APASS
DetailsPhil Shearer
Call 30 min before // Jeremy Phone #: ###-####
BLD-Framing/Rough-in2/10/20152/11/20152/11/2015PFAIL
DetailsPhil Shearer
Jeremy Phone #: ###-####. Headers not installed as per aproved pans, missing bracing on truss c-4, need fire blocking at froint entery.
BLD-Wall Bracing1/28/20151/29/20151/29/2015APASS
DetailsJim Storey
Jeremy-please call 45 min prior Phone #: ###-####
BLD-Wall Bracing1/27/20151/28/20151/28/2015AFAIL
DetailsDave Hannah
Jeremy Phone #: ###-#### needs to block and nail horz seams
Plan Modification Accepted  1/23/2015 DONE
new manual j report
Routing - MECHANICAL1/23/2015 1/23/2015 PASS
DetailsTroy James
resubmitted manual j report
BLD-Foundation10/30/201410/31/201410/31/2014APASS
DetailsPhil Shearer
Request inspection about 9:00. We are scheduled to pour at 11 am Phone #: ###-#### Inspection requested via web by Ben Sears
BLD-Foundation10/30/201410/31/201410/31/2014APASS
DetailsPhil Shearer
Request inspection about 9:00. We are scheduled to pour at 11 am Phone #: ###-#### Inspection requested via web by Ben Sears
BLD-Footing10/14/201410/14/201410/14/2014PPASS
DetailsPhil Shearer
Request early afternoon inspection Phone #: ###-#### Inspection requested via web by Ben Sears
OVERRIDE  10/7/2014  
PubWorks Subgrade Approval10/7/201410/7/201410/7/2014 DONE
DetailsJason C. Taylor
A letter from the applicant’s geotechnical engineer indicating that the footing subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
Permit Ready to Issue  10/7/2014 DONE
Issue PAID IN FULL permit  10/7/2014 DONE
Inspection Record Card- Bld  10/7/2014 DONE
Plan assigned to (JG)9/5/20149/5/20149/29/2014 PASS
DetailsJavier Guzman
1st review completed, 9/23 T L2 Hillside ePlan*
Routing - PLAN CHECK9/19/2014 9/29/2014 PASS
DetailsJavier Guzman
PLANS/APPL TAKEN TO FRONT DESK  9/29/2014 DONE
Routing - PLANNING9/26/2014 9/26/2014 PASS
DetailsDavid Moser
The retaining wall in side yard setback is only 5 feet high and driveway has been reduced to about 33 feet wide in the front yard setback
Routing PW Grading-Hillside9/26/2014 9/26/2014 PASS
DetailsJason C. Taylor
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at ###-####

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at ###-####.

1st review completed  9/19/2014 FAIL
DetailsJavier Guzman
ePlan
Routing - PLAN CHECK9/5/2014 9/19/2014 FAIL
DetailsJavier Guzman
Routing - MECHANICAL9/16/2014 9/16/2014 PASS
DetailsTroy James
Routing - FIRE9/5/20149/5/20149/11/2014 PASS
DetailsScott Arellano
This plan has been evaluated for Fire Department Vehicle Access.
Routing - MECHANICAL9/5/2014 9/9/2014 FAIL
DetailsTroy James
emailed corrections to air energy of idaho
Routing PW Grading-Hillside9/5/2014 9/9/2014 FAIL
DetailsJason C. Taylor
Grading plna needs revised to match Planning & Zoning notes. Grading plan is not signed by the design engineer.
Routing - PLANNING9/5/2014 9/8/2014 FAIL
DetailsDavid Moser
The driveway exceeds 33 feet in width in front yard setback and the screen fence and retaining wall exceeds 6 feet in height in side yard
Routing - PUBLIC WORKS9/5/2014 9/8/2014 PASS
DetailsJennifer Bruner
Routing - Addressing9/5/2014 9/8/2014 PASS
DetailsEmily Dixon
Routing - Erosion and Sediment9/5/2014 9/8/2014 PASS
DetailsEvan Jenkins
Site Prep Inspection and Approval Required Prior to any Earth Disturbance
Recd Pcfee & Taken To Pln CK  9/5/2014 DONE
DetailsCandy A. Nichols
Intake Approval  9/5/2014 PASS
DetailsChristina Prado
Intake Approval  8/26/2014 FAIL
DetailsChristina Prado
Needs stamped foundation plans, structural calcs and rescheck
Application received  7/17/2014 DONE
Application submitted via PDS Online on Jul 17 2014 2:25PM