Second Notice | | 10/16/2014 | 10/12/2014 | | DONE |
|
|
|
This permit finaled on the web by Justin Dauby
|
First Notice | | 9/7/2014 | 10/6/2014 | | DONE |
Candy A. Nichols
|
|
|
sent in mail 10-6-14
|
Case Summary (BLD) | | | 9/23/2014 | | DONE |
|
|
|
|
FIRE-Final Inspection | 8/27/2014 | 8/27/2014 | 8/28/2014 | P | PASS |
Forrest France
|
|
|
Fire life safety inspection completed and passed.
|
BLD-Final | 8/27/2014 | 8/28/2014 | 8/28/2014 | A | PASS |
Jim Storey
|
|
|
Please call ahead for meet/access - Mark Phone #: ###-####
|
Permanent Occupancy | | | 8/28/2014 | | DONE |
|
|
|
|
BLD-Ceiling Grid Inspection | 8/26/2014 | 8/26/2014 | 8/26/2014 | P | PASS |
Jim Storey
|
|
|
Mark Phone #: ###-####
|
BLD-Framing/Rough-in | 8/13/2014 | 8/14/2014 | 8/14/2014 | A | PASS |
Dave Hannah
|
|
|
Mark Phone #: ###-####
|
BLD-Framing/Rough-in | 8/12/2014 | 8/13/2014 | 8/13/2014 | P | DEFR |
Jim Storey
|
|
|
Mark Phone #: ###-#### out of time
|
FIRE-Conference | 8/13/2014 | 8/13/2014 | 8/13/2014 | P | DONE |
Forrest France
|
|
|
On site conference regarding fire code review note items including door hardware, smoke detection, existing fire alarm system and modifications to be included, IFC and BMC conditions.
|
OVERRIDE | | | 8/11/2014 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 8/11/2014 | | DONE |
Candy A. Nichols
|
|
|
|
Plan assigned to (TLW) | 7/25/2014 | | 8/11/2014 | | PASS |
Tim L. Woodard
|
|
|
Level 3 TI - Paper - Bluebird Preschool
|
Routing - FIRE | 8/8/2014 | | 8/11/2014 | | PASS |
|
|
|
See Fire Plan Review 08-11-14
|
1st review completed | | | 8/11/2014 | | DONE |
|
|
|
Failed: Design Review
|
Routing - PLAN CHECK | 8/11/2014 | | 8/11/2014 | | PASS |
Tim L. Woodard
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/11/2014 | | DONE |
Tim L. Woodard
|
|
|
|
Case Summary (BLD) | | | 8/11/2014 | | DONE |
Tim L. Woodard
|
|
|
|
Print Occupancy Form | | | 8/11/2014 | | DONE |
Candy A. Nichols
|
|
|
|
Permit Ready to Issue | | | 8/11/2014 | | DONE |
Candy A. Nichols
|
|
|
|
Routing - PLAN CHECK | 8/1/2014 | | 8/8/2014 | | PASS |
Tim L. Woodard
|
|
|
Approved with Plan Review Report. TLW
|
Routing - Design Review | 8/6/2014 | | 8/6/2014 | | PASS |
Josh Wilson
|
|
|
Ok per CZC14-00236
|
Routing - PLANNING | | | 8/1/2014 | | PASS |
Susan Riggs
|
|
|
Susan Riggs - CUP14-00028
|
Routing - Design Review | 7/31/2014 | | 8/1/2014 | | FAIL |
Sarah Schafer
|
|
|
Sarah Schafer - Left Message with Steve Kamm at ZGA that a Zoning Certificate is needed for the exterior changes including the ramp, handrail, relocation of accessible parking. He needs to submit app, Sheet A-102, photographs and fee.
|
Routing - Erosion and Sediment | 7/29/2014 | | 7/31/2014 | | PASS |
Andy J. Long
|
|
|
ESC plan waiver approved. Need to designate an RP
|
Routing - PUBLIC WORKS | 7/28/2014 | | 7/29/2014 | | PASS |
Jennifer Bruner
|
|
|
|
Routing PW Drainage | 7/29/2014 | | 7/29/2014 | | PASS |
Brian Murphy
|
|
|
approved per Brian Murphy
|
Plan resubmittals received | | | 7/28/2014 | | DONE |
Candy A. Nichols
|
|
|
received 2 each: sheets A-101 & A-102 and letter from ACHD-took to Jason Taylor
|
Routing - Addressing | 7/25/2014 | | 7/28/2014 | | PASS |
Jason C. Taylor
|
|
|
|
Intake Approval | | | 7/25/2014 | | PASS |
Jason Blais
|
|
|
|
Pending Assignment by JCB | 7/25/2014 | | 7/25/2014 | | DONE |
Jason Blais
|
|
|
|
Plan Reviewer's activity | | | 7/25/2014 | | DONE |
Jason Blais
|
|
|
Emailed architect representative to contact CDHD and ACHD for approval and verification documents to be provided prior to the building permit being issued.
|
Application received | | 7/24/2014 | | | |
|
|
|
|