First Notice | | 4/19/2015 | 7/2/2015 | | DONE |
|
|
|
This permit finaled on the web by Jeremy Amar
|
BLD-Final | 4/8/2015 | 4/9/2015 | 4/9/2015 | A | PASS |
Mike Jordan
|
|
|
Jeremy Phone #: ###-####. Ok for perm occ.
|
Permanent Occupancy | | | 4/9/2015 | | DONE |
|
|
|
|
Zoning Approval | 4/8/2015 | 4/8/2015 | 4/8/2015 | | PASS |
Josh Wilson
|
|
|
|
BLD-Footing | 2/11/2015 | 2/12/2015 | 2/12/2015 | A | CANC |
Mike Jordan
|
|
|
Pat Phone #: ###-####
|
Temporary Occupancy | 1/30/2015 | 4/30/2015 | 1/30/2015 | | DONE |
Kristal Soland
|
|
|
|
Temporary Occupancy | 1/29/2015 | 4/29/2015 | 1/29/2015 | | DONE |
Christina Prado
|
|
|
|
BLD-Final | 1/28/2015 | 1/28/2015 | 1/28/2015 | P | PART |
Mike Jordan
|
|
|
Pat Phone #: ###-####. ok for temp. occ. Will be ok for perm. occ. once zoning signs perm.
|
FIRE-Final Inspection | 1/23/2015 | 1/27/2015 | 1/27/2015 | A | PASS |
Troy Cobbley
|
|
|
life safety passed
|
FIRE-Final Inspection | 1/22/2015 | 1/23/2015 | 1/23/2015 | P | CANC |
Troy Cobbley
|
|
|
Cancelle per Pat Phone. have a frozen pipe #: ###-####
|
Zoning Approval Temp | 1/9/2015 | 1/9/2015 | 1/9/2015 | | PASS |
Josh Wilson
|
|
|
Bond in place for landscaping.
|
BLD-Ceiling Grid Inspection | 12/31/2014 | 1/2/2015 | 1/2/2015 | A | PASS |
Mike Jordan
|
|
|
Contact Pat Palmer - RC Channel Inspection Phone #: ###-#### Inspection requested via web by Jeremy Amar
|
BLD-Framing/Rough-in | 12/22/2014 | 12/23/2014 | 12/23/2014 | A | PASS |
Mike Jordan
|
|
|
energy and reinspections // pat Phone #: ###-####
|
BLD-Framing/Rough-in | 12/17/2014 | 12/18/2014 | 12/18/2014 | A | FAIL |
Mike Jordan
|
|
|
and sheer //Pat Phone #: ###-####. fireblock up stairs at dryer vents through top plates, lateral brace vtop chords at overbuild, box out bathroom vent fan at 1st floor floor ceiling. nail off all simpson hangars. ok to insulate.
|
BLD-Wall Bracing | 12/17/2014 | 12/18/2014 | 12/18/2014 | A | PASS |
Mike Jordan
|
|
|
sheer //Pat Phone #: ###-####
|
BLD-Foundation | 9/9/2014 | 9/10/2014 | 9/10/2014 | P | PASS |
Mike Jordan
|
|
|
John Phone #: ###-####
|
BLD-Footing | 9/8/2014 | 9/9/2014 | 9/9/2014 | P | PASS |
Mike Jordan
|
|
|
John Phone #: ###-####
|
BLD-Footing | 9/5/2014 | 9/8/2014 | 9/8/2014 | P | NR |
Mike Jordan
|
|
|
john Phone #: ###-####
|
Issue PAID IN FULL permit | | | 9/3/2014 | | DONE |
Tisha Gallop
|
|
|
|
Print Occupancy Form | | | 9/3/2014 | | DONE |
Tisha Gallop
|
|
|
|
OVERRIDE | | | 9/2/2014 | | |
|
|
|
|
1st review completed | | | 9/2/2014 | | DONE |
Sam Zahorka
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/2/2014 | | DONE |
Sam Zahorka
|
|
|
|
Permit Ready to Issue | | | 9/2/2014 | | DONE |
Christina Prado
|
|
|
|
Routing PW Drainage | 8/6/2014 | | 9/2/2014 | | PASS |
Brian Murphy
|
|
|
Signed off in ePlanReview
|
Plan assigned to (SRZ) | 8/4/2014 | | 9/2/2014 | | PASS |
Sam Zahorka
|
|
|
|
Routing - PLAN CHECK | 8/4/2014 | | 9/2/2014 | | PASS |
Sam Zahorka
|
|
|
|
Routing - PLANNING Land Div | 8/4/2014 | | 9/2/2014 | | PASS |
Dave Abo
|
|
|
Signed off by Todd Tucker in ePlanReview
|
Route to Impact Fee Review | 8/4/2014 | 8/7/2014 | 8/26/2014 | | PASS |
Cindy M. Gould
|
|
|
Impact fees assessed manually.
|
Routing - Design Review | 8/4/2014 | | 8/12/2014 | | PASS |
Josh Wilson
|
|
|
|
Routing - MECHANICAL | 8/4/2014 | | 8/8/2014 | | PASS |
Troy James
|
|
|
|
Routing PW Street Lights | 8/6/2014 | | 8/6/2014 | | PASS |
Mike D Hedge
|
|
|
Street lights already installed.
|
Routing - PUBLIC WORKS | 8/4/2014 | | 8/6/2014 | | PASS |
Beverly Mountain
|
|
|
|
Routing - Erosion and Sediment | 8/4/2014 | | 8/5/2014 | | PASS |
Evan Jenkins
|
|
|
Site Prep Inspection and Approval Required Prior to Earth Disturbance Activities
|
Routing - FIRE | 8/4/2014 | | 8/5/2014 | | PASS |
|
|
|
See Fire Plan Review 08-05-14
|
Routing - PLUMBING | 8/4/2014 | | 8/5/2014 | | PASS |
Daryl Spivey
|
|
|
Per plan and ISPC
|
Routing - Addressing | 8/4/2014 | | 8/4/2014 | | PASS |
Emily Dixon
|
|
|
|
Pending Assignment by JCM | 8/4/2014 | | 8/4/2014 | | DONE |
John Menard
|
|
|
|
Application received | | | 7/30/2014 | | DONE |
|
|
|
Application submitted via PDS Online on Jul 30 2014 10:51AM
|