Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberBLD14-02560
StatusIssued
Name STRIDE ERIC P
Site Address 437 E CAVE CT
Project NameSuzy & Eric Stride Residence
Customer Number 
ePlanReviewYes
Description
WUI Zone A, Class A Roof, Permit for the construction of a new 2892 sq. ft., two story (first story 1833 sq. ft., basement is 1059 sq. ft.) single family dwelling with 4 bedrooms, 3 bathrooms, approximately 158 sq. ft. of covered patio’s/porches and 805 sq. ft. attached garage per the approved plans, plan review report and any notations. R-1A zoning and setbacks per planning. A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at 384-3946

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at 384-3946.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/29/20155/29/20155/29/2015PPART
DetailsTony Young
Eric Phone #: ###-####,, ok to move items in,, need to make hand rail meet code
BLD-Final5/28/20155/29/20155/29/2015APEND
DetailsTony Young
Eric Phone #: ###-####
BLD-Final5/28/20155/28/20155/28/2015PPART
DetailsTony Young
Eric Phone #: ###-####,, all ok except the upper exterior guard/hand rail
FIRE-Final Inspection5/27/20155/28/20155/28/2015PCANC
DetailsTroy Cobbley
No life safety sign off required. I left message on contacts voice mail
PubWorks Occupancy Approval5/28/20155/28/20155/28/2015 DONE
DetailsJason C. Taylor
A bond for the sites final grading, retaining walls, and revegetation has been received by Public Works. Occupancy may be approved by the building department. Jason Taylor ###-####.

BLD-Framing/Rough-in3/5/20153/6/20153/6/2015PPART
DetailsTony Young
change day per Eric Phone #: ###-####,, c/n posted on front stairs to meet code by final,, ok to cover interior
BLD-Energy code compliance3/5/20153/6/20153/6/2015APASS
DetailsTony Young
Eric Phone #: ###-####
BLD-Conference3/5/20153/5/20153/5/2015PFAIL
DetailsTony Young
Stair consult - Eric Phone #: ###-####,, exterior stairs not per code at this point
BLD-Framing/Rough-in3/3/20153/4/20153/4/2015APASS
DetailsTony Young
Eric Phone #: ###-#### please call 1/2 hr prior,, ok to insulate
BLD-Framing/Rough-in3/2/20153/3/20153/3/2015APEND
DetailsTony Young
Eric Phone #: ###-#### please call 1/2 hr prior
BLD-Framing/Rough-in3/2/20153/2/20153/2/2015PPART
DetailsTony Young
Eric Phone #: ###-#### please call 1/2 hr prior,, ok to start insulation,, verify elec pass,, redo some shear by front door,, nail girders off,,, strap plates,, add nails in hangers,, add hangers as needed
Plan Modification Accepted  2/11/2015 DONE
new manual j report
Routing - MECHANICAL2/11/2015 2/11/2015 PASS
DetailsTroy James
resubmitted manual j report
BLD-Wall Bracing1/29/20151/30/20151/30/2015APART
DetailsTony Young
Shear // Eric Phone #: ###-####,, ok to build double wall on exterior,, need engineer to ok other shear as built or provide fixes due to changes with hold downs and openings
BLD-Foundation11/21/201411/21/201411/21/2014APART
DetailsJim Sly
Pat-WALL Phone #: ###-####
Walls at Stairway and 10' South retaining wall.
BLD-Foundation11/12/201411/13/201411/13/2014APEND
DetailsJim Sly
Pat Phone #: ###-####
Told Contractor they cannot pour per cold weather concrete provisions.
BLD-Footing11/10/201411/10/201411/10/2014PPART
DetailsJim Sly
Pat Phone #: ###-####
80 percent complete WIP appears OK.
PubWorks Subgrade Approval11/10/201411/10/201411/10/2014 DONE
DetailsJason C. Taylor
*FOOTINGS & PADS ONLY*A letter from the applicant’s geotechnical engineer indicating that the footing subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
OVERRIDE  10/28/2014  
Issue PAID IN FULL permit  10/28/2014 DONE
Inspection Record Card- Bld  10/28/2014 DONE
Permit Ready to Issue  10/28/2014 DONE
Plan assigned to (JG)9/30/20149/30/201410/27/2014 PASS
DetailsJavier Guzman
1st review completed, Pending Hillside, 10/16 TH L2 hillside ePlan**
Routing PW Grading-Hillside10/27/2014 10/27/2014 PASS
DetailsJason C. Taylor
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at ###-####

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at ###-####.
PLANS/APPL TAKEN TO FRONT DESK  10/27/2014 DONE
Telephone call  10/27/2014 DONE
called Mark Wagner and left vm need GC, RP and verification of value on application.
Routing - PLAN CHECK10/17/2014 10/24/2014 PASS
DetailsJavier Guzman
1st review completed  10/17/2014 DONE
DetailsJavier Guzman
Routing - PLAN CHECK9/30/2014 10/17/2014 FAIL
DetailsJavier Guzman
ePlan review
Routing - FIRE9/30/20149/30/201410/1/2014 PASS
DetailsScott Arellano
This structure has been evaluated for Fire Department Vehicle access. Additionally, this structure is required to comply with the 30 foot Defensible Space provisions of the Boise Municipal Code 7-01-69 section 4920.
Routing PW Grading-Hillside9/30/2014 9/30/2014 FAIL
DetailsJason C. Taylor
See changemarks in ePlan. JCT ###-####
Routing - MECHANICAL9/30/2014 9/30/2014 PASS
DetailsTroy James
Routing - PLANNING9/30/2014 9/30/2014 PASS
DetailsSue Cummings
Routing - Addressing9/30/2014 9/30/2014 PASS
DetailsEmily Dixon
Routing - PUBLIC WORKS9/30/2014 9/30/2014 PASS
DetailsJennifer Bruner
Routing - Erosion and Sediment9/30/2014 9/30/2014 PASS
DetailsEvan Jenkins
Site Prep Inspection and Approval Required Prior to Earth Disturbance
Plans ACCEPTED BY PLAN TECH  9/30/2014 DONE
DetailsChristina Prado
Intake Approval  9/30/2014 PASS
DetailsChristina Prado
Recd Pcfee & Taken To Pln CK  9/30/2014 DONE
DetailsChristina Prado
Intake Approval  9/23/2014 FAIL
DetailsCandy A. Nichols
need ACCA, res-check, attic access, and drawing uploaded individually not in packet
Application received  8/29/2014 DONE
Application submitted via PDS Online on Aug 29 2014 10:02AM