Permit Information
Permit NumberBLD15-00229
StatusFinaled
Name BRUNO BUILT INC
Site Address 2620 E WINDSONG DR
Project NameKuhlmeier Residence
Customer Number 
ePlanReviewYes
Description
WUI Zone A, class A roof, Permit for the construction of a new 5035 sq. ft., two story (upper level 2931 sq. ft., lower level 2104 sq. ft.) single family dwelling with 4 bedrooms, 2 bathrooms, 2 half bathrooms , approximately 862 sq. ft. of covered patio/porch and a 1066 sq. ft. attached garage per the approved plans, plan review report and any notations. R-1A/DA zoning and setbacks per planning. A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at 384-3946

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at 384-3946.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
PubWorks Occupancy Approval4/8/20164/8/20164/8/2016 DONE
DetailsJason C. Taylor
A letter from the applicant’s civil engineer indicating that the final grading and drainage is acceptable has been received by Public Works. Final occupancy may be approved by the building department. Jason Taylor ###-####.
BLD-Final12/10/201512/14/201512/14/2015APASS
DetailsPhil Shearer
Change day and time per Robert Phone #: ###-#### (bond posted for site stabilization)
DOC - Permit Finaled12/14/201512/14/201512/14/2015PPASS
DetailsPhil Shearer
PubWorks Occupancy Approval12/11/201512/11/201512/11/2015 DONE
DetailsJason C. Taylor
A bond for the sites final grading and re-vegetation has been received by Public Works. Occupancy may be approved by the building department. Jason Taylor ###-####.
BLD-Other9/14/20159/14/20159/14/2015PPASS
DetailsPhil Shearer
Drywall/soffit/firewall inspection please Phone #: ###-#### Inspection requested via web by Janene Dodds
BLD-Framing/Rough-in8/25/20158/26/20158/26/2015PCANC
DetailsJim Storey
Re-inspection for Framing Phone #: ###-#### Inspection requested via web by Janene Dodds passed previously
BLD-Energy code compliance8/24/20158/25/20158/26/2015PPASS
DetailsDave Hannah
Insulation Inspection please Phone #: ###-#### Inspection requested via web by Janene Dodds
BLD-Framing/Rough-in8/24/20158/25/20158/26/2015PPASS
DetailsDave Hannah
Framing Re-Inspection please Phone #: ###-#### Inspection requested via web by Janene Dodds
BLD-Framing/Rough-in8/20/20158/24/20158/24/2015APART
DetailsPhil Shearer
CN posted Fire blocking upstairs and down stairs, truss bracing and girder nailing, truss hanger nailing, Engineering for headers in the bacement.
Plan Modification Accepted  8/21/2015 DONE
new manual j report
Routing - MECHANICAL8/21/2015 8/21/2015 PASS
DetailsTroy James
resubmitted manual j report
BLD-Wall Bracing8/5/20158/6/20158/6/2015PPASS
DetailsDave Hannah
Re-inspection plus inspection for fire soffits Phone #: ###-#### Inspection requested via web by Janene Dodds
BLD-Wall Bracing8/4/20158/5/20158/6/2015APASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Janene Dodds ok to cover ext
BLD-Wall Bracing8/5/20158/6/20158/5/2015ACANC
DetailsDave Hannah
Reinspection
Plus Fire Soffit Phone #: ###-#### >> Inspection requested via web by Janene Dodds Inspection cancelled from web by: Janene Dodds
BLD-Foundation4/13/20154/13/20154/13/2015PPASS
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by Ben Sears
BLD-Foundation4/13/20154/13/20154/13/2015ANR
DetailsPhil Shearer
ready at 11:00
Phone #: ###-#### Inspection requested via web by Jay Jones
BLD-Footing4/2/20154/2/20154/2/2015APASS
DetailsPhil Shearer
Will be ready around 10 Phone #: ###-#### Inspection requested via web by Ben Sears
PubWorks Subgrade Approval3/30/20153/30/20153/30/2015 DONE
DetailsJason C. Taylor
Crawl Space & Basement Footings Only****A letter from the applicant’s geotechnical engineer indicating that the footing subgrade is acceptable has been received by Public Works. Footing inspection may be scheduled with the Building Department. Jason Taylor ###-####.
Issue PAID IN FULL permit  3/19/2015 DONE
Inspection Record Card- Bld  3/19/2015 DONE
OVERRIDE  3/18/2015  
Permit Ready to Issue  3/18/2015 DONE
DetailsCandy A. Nichols
requirements met
Plan assigned to (JG)2/23/20152/23/20153/17/2015 PASS
DetailsJavier Guzman
1st review completed, 3/11 W L2 Hillside ePlan**
PLANS/APPL TAKEN TO FRONT DESK  3/17/2015 DONE
Routing - PLAN CHECK2/27/2015 3/17/2015 PASS
DetailsJavier Guzman
Routing - MECHANICAL3/13/2015 3/13/2015 PASS
DetailsTroy James
1st review completed  2/27/2015 FAIL
DetailsJavier Guzman
Routing - PLAN CHECK2/23/2015 2/27/2015 FAIL
DetailsJavier Guzman
ePlan
Routing - FIRE2/23/20152/23/20152/26/2015 PASS
DetailsScott Arellano
This structure has been evaluated for Fire Department vehicle access.
Routing - MECHANICAL2/23/2015 2/25/2015 FAIL
DetailsTroy James
emailed a1 heating
Routing - PLANNING2/23/2015 2/23/2015 PASS
DetailsLeon Letson
Routing - Addressing2/23/2015 2/23/2015 PASS
DetailsEmily Dixon
Routing - PUBLIC WORKS2/23/2015 2/23/2015 PASS
DetailsJennifer Bruner
Routing - Erosion and Sediment2/23/2015 2/23/2015 PASS
DetailsEvan Jenkins
(SITE PREP INSPECTION REQUIRED)
Permit for the construction of a new 5035 sq. ft., two story (upper level 2931 sq. ft., lower level 2104 sq. ft.) single family dwelling with 4 bedrooms, 2 bathrooms, 2 half bathrooms , approximately 330 sq. ft. of covered patio/porch and a 1066 sq. ft. attached garage per the approved plans,
Plans ACCEPTED BY PLAN TECH  2/23/2015 DONE
DetailsChristina Prado
Override - Parcel Holds  2/23/2015  
Recd Pcfee & Taken To Pln CK  2/23/2015 DONE
DetailsChristina Prado
Intake Approval  2/23/2015 PASS
DetailsChristina Prado
Routing PW Grading-Hillside2/23/2015 2/23/2015 PASS
DetailsJason C. Taylor
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at ###-####

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at ###-####.
Application received  1/29/2015 DONE
Application submitted via PDS Online on Jan 29 2015 4:16PM