Third Notice | | 6/14/2015 | 6/24/2015 | | DONE |
|
|
|
This permit finaled on the web by Karen Trusty
|
Second Notice | | 5/16/2015 | 6/9/2015 | | DONE |
|
|
|
sent in mail
|
First Notice | 3/24/2015 | 3/24/2015 | 5/6/2015 | | DONE |
Mike Jordan
|
|
|
|
BLD-Final | 3/24/2015 | 3/24/2015 | 3/24/2015 | P | PASS |
Mike Jordan
|
|
|
|
DOC - Permit Finaled | 3/24/2015 | 3/24/2015 | 3/24/2015 | P | PASS |
Mike Jordan
|
|
|
|
FIRE-Final Inspection | 3/23/2015 | 3/24/2015 | 3/24/2015 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed
|
Issue PAID IN FULL permit | | | 3/23/2015 | | DONE |
Christina Prado
|
|
|
|
Inspection Record Card- Bld | | | 3/23/2015 | | DONE |
Christina Prado
|
|
|
|
Permit Ready to Issue | | | 3/20/2015 | | DONE |
|
|
|
NEED GC form and Certificate of Value
|
Plan assigned to (CDM) | 3/18/2015 | 3/18/2015 | 3/19/2015 | | PASS |
Carl D Madsen
|
|
|
Level 2 TI - ePlanReview - Racking
|
Routing - FIRE | 3/18/2015 | 3/18/2015 | 3/19/2015 | | PASS |
Scott Arellano
|
|
|
No comments attached.
|
1st review completed | | | 3/19/2015 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/19/2015 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 3/18/2015 | | 3/19/2015 | | PASS |
Carl D Madsen
|
|
|
|
Intake Approval | | | 3/18/2015 | | PASS |
Jason Blais
|
|
|
|
Pending Assignment by JCB | 3/18/2015 | | 3/18/2015 | | DONE |
Jason Blais
|
|
|
|
Plan Reviewer's activity | | | 3/11/2015 | | FAIL |
|
|
|
I sent the following email. The application failed prescreen
In performing the prescreen racking review I have noted the following omission or errors:
Omission – Form #516 – Commercial Racking/Shelving Submittal Checklist
Omission - Form #302 – Contractors Registration Declaration
Omission – Form #306 – Certificate of Value
Omission – ICC Evaluation Service Report
Error - Form #310 – Is present but has not been completed. Please, do not forget the stamp for the Design Engineer or Architect
Error – Reflected Ceiling Plan A200 – Has a symbol for emergency lights however, none are shown on the plan view. Please, show location of emergency lights.
Error – Fixture Plan – The fixture plan does not show the location of the fire extinguishers. Please, show the location of the fire extinguishers.
Error – Provide the note indicated on the check list (second item from the bottom on page 3) on the drawing.
The omissions and errors are required to be corrected before the racking permit can be reviewed.
Please, feel free to contact me with any questions.
Cordially,
Tim Frost, S.E.T.
Fire Sprinkler Plans Examiner
Fire Code Plans Examiner
Fire Inspector
City of Boise
tfrost@cityofboise.org
###-####
|
Application received | | | 3/4/2015 | | DONE |
|
|
|
Application submitted via PDS Online on Mar 4 2015 6:43PM
|