Permit Information
Permit NumberBLD15-01111
StatusFinaled
Name BACH LAND AND DEVELOPMENT LLC
Site Address 7466 W SAXTON DR
Project NameThe Kensington Apartments P
Customer NumberBLD15-01107 IN EPLAN
ePlanReview 
Description
(THE KENSINGTON APARTMENTS - BUILDING P) The drawings are filed under BLD15-01107 in ePlanReview. The NFPA 13-R fire sprinkler system is used for occupancy and for story increase. To construct a 42,002 square foot four story apartment building (10,836 sq. ft. 1st story with two 2.e units, five 2.a units, and one 2.g unit, 10,815 sq. ft. 2nd story with seven 2.a units and one 2.g unit, 10,815 sq. ft. 3rd story with seven 2.a units and one 2.g unit, and 9,536 sq. ft. 4th story with four 1.b units, three 2.a units, and one 2.g unit). An elevator is provided in this building that serves all stories. All units in this building are required to comply as Type B dwelling units. Of those Type B dwelling units, 2 will also comply as Type A units. Work is to include concrete footings, concrete foundations, concrete slabs on grade, wood stud bearing walls, wood stud shear walls, fiberglass shingles, fiber-cement board siding, manufactured stone veneer, a 2-hr elevator shaft, 1-hr dwelling unit separations, .5-hr minimum fire-resistance-rated corridors with 20 minute smoke- and draft-control doors, exterior exit stairways fire rated like the corridors, steel stairways with concrete treads, interior nonbearing walls, millwork, and finishes. Special Inspection is required for soils and for concrete. The roof truss design is a deferred submittal item. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13-R and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permanent Occupancy  3/28/2017 DONE
DetailsChristina Prado
PubWorks Occupancy Approval3/27/20173/27/20173/27/2017 DONE
DetailsTiffany Lowery
BLD-Final3/22/20173/23/20173/24/2017PPASS
DetailsTony Young
Ed Phone #: ###-####
FIRE-Final Inspection3/22/20173/23/20173/23/2017ACANC
DetailsJim Page
Life fire safety inspection was completed on 2/16/2017 per notes in activities.
FIRE-Final Inspection2/15/20172/16/20172/16/2017APASS
DetailsJim Page
Previously noted items have been completed. Final fire sprinkler inspection complete, final fire alarm inspection is complete, fire extinguishers are in place with curent inspection tags, knox box is in place, knox caps are in place on FDC/standpipe. Final life fire safety inspection passed/complete.
BLD-Aging Inspection2/13/20172/13/20172/14/2017 PEND
DetailsTony Young
Temporary Occupancy1/30/20174/30/20171/30/2017 DONE
DetailsChristina Prado
Zoning Approval1/30/20171/30/20171/30/2017 DONE
DetailsAndrea Tuning
Print Occupancy Form  1/30/2017 DONE
BLD-Framing/Rough-in12/14/201612/14/201612/14/2016PCANC
DetailsTony Young
ed Phone #: ###-####
BLD-Final12/13/201612/14/201612/14/2016APART
DetailsTony Young
Ed Phone #: ###-####,, temp occ ok,, see Hillary for the notes for each unit,, then ok after min. fixes and after Fire final
FIRE-Final Inspection12/14/201612/14/201612/14/2016PCANC
DetailsJim Page
Inspection request cancelled.
FIRE-Final Inspection12/13/201612/13/201612/13/2016PPART
DetailsJim Page
Partial life fire safety inspection complete, final fire sprinkler inspection complete, final fire alarm inspection partially complete (refer to activities under FIR16-00749 for alarm notes), knox box is in place, FDC knox caps are in place, fire extinguishers are in place with current inspection tags. Life fire safety can be signed of as finaled when the elevator recall function and elevator smoke detectors are tested and complete.
FIRE-Final Inspection12/9/201612/12/201612/12/2016PCANC
DetailsJim Page
Inspection request will need to be rescheduled, FIR permits for both fire sprinkler and fire alarm are still in issued status, partial final inspection has been completed on fire sprinklers, remaining items that need to be inspected for fire sprinkler are associated with the fire alarms (this has been noted under FIR16-00266 activities), no inspection request for FIR16-00749 has been made from the fire alarm contractor for the final fire alarm system inspection (fire alarm contractor needs to request final fire alarm inspection). Final life fire safety inspection will not happen until FIR permits are in finaled status as mentioned before. This inspection request is cancelled.
FIRE-Final Inspection12/2/201612/5/201612/5/2016ACANC
DetailsJim Page
Inspection request will need to be rescheduled, FIR permits for both fire sprinkler and fire alarm are still in issued status and no final has been completed for FIR permits. This inspection request is cancelled.
Print Occupancy Form  11/29/2016 DONE
BLD-Energy code compliance9/23/20169/26/20169/26/2016APART
DetailsTony Young
prerock areas ok
BLD-Energy code compliance9/23/20169/23/20169/23/2016PNR
DetailsDave Hannah
insulation // Ed Phone #: ###-####
BLD-Energy code compliance9/8/20169/9/20169/9/2016APART
DetailsTony Young
1st floor; Ed Phone #: ###-####,, ok pending trades
BLD-Framing/Rough-in9/8/20169/8/20169/8/2016PPASS
DetailsTony Young
1st floor; Ed Phone #: ###-####
BLD-Wall Bracing9/8/20169/8/20169/8/2016PPASS
DetailsTony Young
1st floor; Ed Phone #: ###-####
BLD-Framing/Rough-in9/6/20169/7/20169/8/2016APART
DetailsTony Young
1st floor; Ed Phone #: ###-####,, ok to insulate,,
BLD-Framing/Rough-in9/6/20169/6/20169/6/2016PDEFR
DetailsTony Young
1st floor; Ed Phone #: ###-####
BLD-Energy code compliance8/25/20168/26/20168/26/2016APART
DetailsTony Young
Ed// 3rd floor Phone #: ###-####,, 2nd and 3rd floor ok
BLD-Framing/Rough-in8/24/20168/25/20168/25/2016APART
DetailsTony Young
2nd & 3rd floor; Ed Phone #: ###-####,, fur downs ok,, fire treated / lumber drops ok
BLD-Framing/Rough-in8/22/20168/23/20168/23/2016APART
DetailsTony Young
Ed// 1st floor Phone #: ###-####,, prerock ok
BLD-Framing/Rough-in8/17/20168/17/20168/17/2016PPART
DetailsJim Sly
1st floor; Doug Phone #: ###-####
OK to pre-rock.
BLD-Energy code compliance8/1/20168/1/20168/1/2016PPART
DetailsTony Young
4th floor - Ed Phone #: ###-####,, ceilings in 4th floor units ok,, not exterior hallway until fire passes
FIRE-Conference8/1/20168/1/20168/1/2016PCANC
DetailsJim Page
Tenting inspection needs to be under FIR16-00266, this inspection request cancelled and a new inspection request for the correct permit will be generated.
BLD-Energy code compliance7/28/20168/1/20168/1/2016ANR
DetailsTony Young
4th floor - Ed Phone #: ###-####,, need fire sprinkler sign off
BLD-Energy code compliance7/27/20167/28/20167/28/2016ANR
DetailsTony Young
4th floor - Ed Phone #: ###-####
BLD-Framing/Rough-in7/26/20167/27/20167/27/2016ANR
DetailsTony Young
4th floor - Ed Phone #: ###-####,, need the same
BLD-Energy code compliance7/25/20167/26/20167/26/2016APEND
DetailsTony Young
4th floor - Ed Phone #: ###-####,, same condition
BLD-Energy code compliance7/22/20167/25/20167/25/2016APEND
DetailsTony Young
4th floor - Ed Phone #: ###-####,, ok pending sprinkler tenting and resolve of the ceiling r valule under overbuild
BLD-Framing/Rough-in7/21/20167/22/20167/22/2016APART
DetailsTony Young
Ed-2nd and 3rd floor Bldg P Phone #: ###-####,, 2nd and 3rd floor ok to insulate and cover drops areas for trade chases,, 4th floor corrections made ok
BLD-Framing/Rough-in7/20/20167/21/20167/21/2016APART
DetailsPhil Shearer
4th floor; Ed Phone #: ###-####. Point load girders, Hangers in halls missing nails, truss clips over deck. Ok to insulate
BLD-Wall Bracing6/1/20166/1/20166/1/2016PPASS
DetailsTony Young
Ed// exterior Phone #: ###-####,, exterior ok to cover
BLD-Wall Bracing5/20/20165/23/20165/23/2016APART
DetailsTony Young
Ed Phone #: ###-####,, interior shear ok after minor fixes
BLD-Wall Bracing5/16/20165/16/20165/16/2016PPART
DetailsTony Young
Ed-roof nailing Phone #: ###-####8,, contractor to verify nailing on roof area,, roof nailing of 4 story
BLD-Footing3/14/20163/15/20163/15/2016APEND
DetailsTony Young
Ed Phone #: ###-####,, pend S. I. report
BLD-Footing2/19/20162/24/20162/24/2016APART
DetailsTony Young
Ed Phone #: ###-####,, spec. inp on site
BLD-Other2/18/20162/19/20162/19/2016APART
DetailsJim Sly
Elevator // Ed Phone #: ###-####
OK pending Geotec special inspection, tests and approvals.
BLD-Foundation2/18/20162/19/20162/19/2016APART
DetailsJim Sly
Rebar // Ed Phone #: ###-####
OK pending Geotec special inspection, tests and approvals.
BLD-Footing1/19/20161/19/20161/19/2016PPART
DetailsTony Young
Barry Phone #: ###-####
BLD-Footing1/19/20161/19/20161/19/2016PPART
DetailsTony Young
Phone #: ###-####,, special insp on site
Issue PAID IN FULL permit  11/24/2015 DONE
Inspection Record Card- Bld  11/24/2015 DONE
OVERRIDE  11/20/2015  
Routing - PLAN CHECK11/11/2015 11/20/2015 PASS
DetailsCarl Westfall
Routing Off Site - STRUCTURAL11/12/2015 11/20/2015 PASS
DetailsCarl Westfall
Jan Welch
Plan Reviewer's activity  11/20/2015 DONE
Routing completed
PLANS/APPL TAKEN TO FRONT DESK  11/20/2015 DONE
Permit Ready to Issue  11/20/2015 DONE
all requirments met
Plan assigned to (CJW)5/21/2015 11/20/2015 PASS
DetailsCarl Westfall
Building P (1st review done)
Routing - PLUMBING11/12/2015 11/19/2015 PASS
DetailsBill VanDegrift
Routing - MECHANICAL11/12/2015 11/17/2015 PASS
DetailsTroy James
Plan resubmittals received  11/11/2015 DONE
Plan resubmittals requested  10/28/2015 DONE
Routing Off Site - STRUCTURAL10/10/2015 10/27/2015 FAIL
DetailsCarl Westfall
Jan Welch
Routing - MECHANICAL10/10/2015 10/23/2015 PASS
DetailsTroy James
Routing - PLUMBING10/10/2015 10/22/2015 FAIL
DetailsDaryl Spivey
see bld15-01107
Routing PW Drainage10/10/2015 10/20/2015 PASS
DetailsJason C. Taylor
Project approved under GRD15-00018 ODI 3398. JCT
Routing - PLANNING10/10/2015 10/20/2015 PASS
DetailsDavid Moser
Routing - PLAN CHECK10/8/2015 10/16/2015 PASS
DetailsCarl Westfall
Drawings approved with redlines after the 2nd IBC review
Routing - Design Review10/10/2015 10/13/2015 PASS
DetailsJosh Wilson
Routing - FIRE10/10/2015 10/12/2015 FAIL
DetailsKatie Marron
Comments not adequately addressed. Report attached to case and emailed to architect.
Routing PW Sewer Rating10/10/2015 10/12/2015 PASS
DetailsJennifer Bruner
Routing PW Sewer Design10/10/2015 10/12/2015 PASS
DetailsKyle S. Rosenmeyer
Routing - PUBLIC WORKS10/10/2015 10/12/2015 PASS
DetailsJennifer Bruner
The 1st work flow broke. Please route this to all those in Public works who need to see it.
Plan resubmittals received  10/8/2015 DONE
Routing PW Drainage9/21/2015 9/21/2015 PASS
DetailsJason C. Taylor
Plan resubmittals requested  8/5/2015 DONE
Workflow in ePlanReview completed
Routing PW Drainage6/1/2015 8/5/2015 FAIL
DetailsJason C. Taylor
Route to Impact Fee Review6/27/20156/30/20156/29/2015 PASS
DetailsCindy M. Gould
Routing - PLAN CHECK5/21/2015 6/27/2015 FAIL
DetailsCarl Westfall
1st review completed  6/27/2015 DONE
Routing Off Site - STRUCTURAL5/21/2015 6/8/2015 FAIL
DetailsCarl Westfall
Jan Welch
Routing PW Sewer Design5/21/2015 6/4/2015 FAIL
DetailsKyle S. Rosenmeyer
Separate sewer review underway in Public Works.
Routing - FIRE5/21/2015 6/3/2015 FAIL
DetailsScott Arellano
Routing - MECHANICAL5/21/2015 6/1/2015 FAIL
DetailsTroy James
Routing PW Drainage5/21/2015 6/1/2015  
DetailsBrian Murphy
Re-assigned to Jason Taylor
Routing PW Sewer Rating5/21/2015 5/28/2015 PASS
DetailsBeverly Mountain
Routing PW Solid Waste5/21/2015 5/28/2015 PASS
DetailsMegan Durrell
Routing - PLANNING Land Div5/28/2015 5/28/2015 PASS
DetailsDave Abo
Routing - Design Review5/21/2015 5/27/2015 PASS
DetailsJosh Wilson
Routing - PLUMBING5/21/2015 5/27/2015 FAIL
DetailsDaryl Spivey
Routing PW Street Lights5/21/2015 5/26/2015 PASS
DetailsMike D Hedge
Street lights to be addressed in submittal #2
Routing - Erosion and Sediment5/26/2015 5/26/2015 PASS
DetailsEvan Jenkins
(APARTMENT BUILDING P)
Routing - PUBLIC WORKS5/21/2015 5/21/2015 PASS
DetailsBeverly Mountain
Intake Approval  5/21/2015 PASS
Pending Assignment by TLW5/21/2015 5/21/2015 DONE
DetailsTim L. Woodard
Routing - Addressing5/21/2015 5/21/2015 PASS
DetailsEmily Dixon
Address corrected to 7466 W Saxton Dr.
Plan Reviewer's activity  5/20/2015 PASS
Plan intake approved
Intake Approval  5/15/2015 FAIL
Intake Approval  5/6/2015 FAIL
Application received  4/9/2015 DONE
Application submitted via PDS Online on Apr 9 2015 3:20PM
First Notice 4/7/2017