Permanent Occupancy | | | 12/4/2017 | | DONE |
Christina Prado
|
|
|
|
BLD-Final | 11/30/2017 | 12/1/2017 | 12/1/2017 | A | PASS |
Tony Young
|
|
|
Ed Phone #: ###-####
|
PubWorks Occupancy Approval | 11/30/2017 | 11/30/2017 | 11/30/2017 | | DONE |
Tiffany Lowery
|
|
|
|
Zoning Approval | 11/21/2017 | 11/21/2017 | 11/21/2017 | | DONE |
Andrea Tuning
|
|
|
|
BLD-Aging Inspection | 9/8/2017 | 9/8/2017 | 9/15/2017 | | PASS |
Tony Young
|
|
|
|
BLD-Aging Inspection | 9/7/2017 | 9/7/2017 | 9/8/2017 | | PASS |
Tony Young
|
|
|
|
BLD-Final | 4/26/2017 | 4/26/2017 | 4/26/2017 | P | PASS |
Tony Young
|
|
|
Ed Phone #: ###-####,, 2nd hand rails going in
|
BLD-Conference | 4/25/2017 | 4/26/2017 | 4/26/2017 | A | PEND |
Tony Young
|
|
|
Ed Phone #: ###-####,, hand rail conf.
|
BLD-Final | 4/24/2017 | 4/25/2017 | 4/25/2017 | P | PART |
Tony Young
|
|
|
Ed Phone #: ###-####,, ok,, needs a 2nd hand rail in stairs serving 2 units
|
FIRE-Final Inspection | 4/24/2017 | 4/25/2017 | 4/25/2017 | A | PASS |
Jim Page
|
|
|
Fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers will be mounted in discussed locations, knox box is in place, thumbturn deadbolts in common area doorways will be changed to double-keyed deadbolts. Final life fire safety inspection passed/complete.
|
BLD-Final | 4/25/2017 | 4/25/2017 | 4/25/2017 | A | PART |
Tony Young
|
|
|
Ed Phone #: ###-####,, walk through only,, note.. need to see why alarm permit is tied to this permit?? need trades
|
Print Occupancy Form | | | 4/17/2017 | | DONE |
|
|
|
|
BLD-Energy code compliance | 2/28/2017 | 3/1/2017 | 3/1/2017 | A | PASS |
Tony Young
|
|
|
Ed-lower levels Phone #: ###-####
|
BLD-Framing/Rough-in | 2/22/2017 | 2/23/2017 | 2/23/2017 | A | PASS |
Tony Young
|
|
|
First level // Ed Phone #: ###-####,, ok to insulate
|
BLD-Energy code compliance | 2/21/2017 | 2/21/2017 | 2/21/2017 | P | PASS |
Tony Young
|
|
|
2nd Floor Insulation Inspection Phone #: ###-#### Inspection requested via web by Barry Willoughby
|
BLD-Wall cover | 2/20/2017 | 2/21/2017 | 2/21/2017 | A | PART |
Tony Young
|
|
|
2nd Floor Insulation Inspection Phone #: ###-#### Inspection requested via web by Barry Willoughby,, 2nd floor ok
|
BLD-Aging Inspection | 2/16/2017 | 2/16/2017 | 2/17/2017 | | PASS |
Tony Young
|
|
|
|
BLD-Framing/Rough-in | 2/15/2017 | 2/16/2017 | 2/16/2017 | A | PART |
Tony Young
|
|
|
Ed Phone #: ###-####,, up stairs only,, ok to insulate,, need to fire stop chases
|
BLD-Aging Inspection | 2/15/2017 | 2/15/2017 | 2/15/2017 | | PEND |
Tony Young
|
|
|
|
BLD-Framing/Rough-in | 2/3/2017 | 2/6/2017 | 2/6/2017 | A | NR |
Tony Young
|
|
|
Ed Phone #: ###-####,, walk through only,, need seal package,, hangers, straps,, temp glass, truss nailing,, bearing, etc
|
BLD-Wall Bracing | 10/3/2016 | 10/4/2016 | 10/4/2016 | A | PASS |
Tony Young
|
|
|
ED Phone #: ###-####,, exterior ok
|
BLD-Footing | 6/21/2016 | 6/22/2016 | 6/22/2016 | A | PART |
Tony Young
|
|
|
Ed Phone #: ###-####,, ok pending special inspection report
|
BLD-Foundation | 5/16/2016 | 5/17/2016 | 5/17/2016 | A | PART |
Jim Sly
|
|
|
stem wall; Ed Phone #: ###-####
|
BLD-Footing | 5/6/2016 | 5/9/2016 | 5/9/2016 | A | PEND |
Tony Young
|
|
|
Ed Phone #: ###-####,, pending special inspection
|
Issue PAID IN FULL permit | | | 4/13/2016 | | DONE |
|
|
|
|
Telephone call | | | 4/11/2016 | | DONE |
|
|
|
Left a message for James, with Bach Homes, informing him that the Kensington Apartment permits are 8 days past their expiration date and recommended he request another extension for 180 days. Also informed him that if he does request the extension it will be the final one that can be given.
|
Permit Ready to Issue | | | 4/8/2016 | | DONE |
|
|
|
All requirements met
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/7/2016 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 3/31/2016 | | 4/7/2016 | | PASS |
Carl Westfall
|
|
|
|
Routing Off Site - STRUCTURAL | 4/1/2016 | | 4/7/2016 | | PASS |
Carl Westfall
|
|
|
Dave Haugland
|
Plan assigned to (CJW) | 7/20/2015 | | 4/7/2016 | | PASS |
Carl Westfall
|
|
|
Building S - Phase 2
|
Routing PW Drainage | 4/1/2016 | | 4/5/2016 | | PASS |
Jason C. Taylor
|
|
|
|
Routing - FIRE | 4/1/2016 | | 4/5/2016 | | PASS |
Katie Marron
|
|
|
No change to previous approval
|
Routing PW Sewer Design | 4/1/2016 | | 4/5/2016 | | PASS |
Kyle S. Rosenmeyer
|
|
|
|
Routing PW Street Lights | 4/1/2016 | | 4/5/2016 | | PASS |
Tom Marshall
|
|
|
|
Routing PW Solid Waste | 4/1/2016 | | 4/4/2016 | | PASS |
Megan Durrell
|
|
|
|
Routing - PUBLIC WORKS | 4/1/2016 | | 4/1/2016 | | PASS |
Rachael Beierle
|
|
|
|
Routing PW Sewer Rating | 4/1/2016 | | 4/1/2016 | | PASS |
Rachael Beierle
|
|
|
|
Routing - Addressing | 4/1/2016 | | 4/1/2016 | | PASS |
Laura Hunter
|
|
|
|
Plan resubmittals received | | | 3/31/2016 | | DONE |
|
|
|
|
Plan resubmittals requested | | | 3/9/2016 | | DONE |
|
|
|
|
Routing Off Site - STRUCTURAL | 2/22/2016 | | 3/8/2016 | | FAIL |
Carl Westfall
|
|
|
Dave Haugland
|
Routing - PLANNING Land Div | 2/22/2016 | | 3/1/2016 | | PASS |
Todd Tucker
|
|
|
|
Routing - PLUMBING | 2/22/2016 | | 3/1/2016 | | PASS |
Bill VanDegrift
|
|
|
|
Routing PW Solid Waste | 2/22/2016 | | 2/29/2016 | | PASS |
Megan Durrell
|
|
|
|
Routing PW Drainage | 2/22/2016 | | 2/26/2016 | | FAIL |
Jason C. Taylor
|
|
|
|
Routing - PLAN CHECK | 2/17/2016 | | 2/25/2016 | | FAIL |
Carl Westfall
|
|
|
|
Routing - MECHANICAL | 2/22/2016 | | 2/25/2016 | | PASS |
Troy James
|
|
|
|
Routing PW Sewer Design | 2/22/2016 | | 2/25/2016 | | PASS |
Kyle S. Rosenmeyer
|
|
|
|
Routing - PUBLIC WORKS | 2/22/2016 | | 2/24/2016 | | PASS |
Jennifer Bruner
|
|
|
|
Routing - FIRE | 2/22/2016 | | 2/24/2016 | | PASS |
Katie Marron
|
|
|
No change from previous approval.
|
Routing - Addressing | 2/22/2016 | | 2/24/2016 | | PASS |
Laura Hunter
|
|
|
|
Routing - Design Review | 2/22/2016 | | 2/24/2016 | | PASS |
Josh Wilson
|
|
|
OK PER MODIFICATION DRH15-00313 JGW 2-24-16
|
Routing PW Sewer Rating | 2/22/2016 | | 2/24/2016 | | PASS |
Jennifer Bruner
|
|
|
|
Plan resubmittals received | | | 2/17/2016 | | DONE |
|
|
|
|
Extend Review Timeline | | | 12/17/2015 | | DONE |
Carl Westfall
|
|
|
Request approved by Jason Blais, Building Official. See attached document under BLD15-01118.
|
Routing PW Drainage | 9/21/2015 | | 9/21/2015 | | PASS |
Jason C. Taylor
|
|
|
|
Route to Impact Fee Review | 8/27/2015 | 8/30/2015 | 8/28/2015 | | PASS |
Cindy M. Gould
|
|
|
|
1st review completed | | | 8/27/2015 | | DONE |
|
|
|
|
Plan resubmittals requested | | | 8/27/2015 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 7/22/2015 | | 8/26/2015 | | FAIL |
Carl Westfall
|
|
|
Revised drawings required
|
Routing Off Site - STRUCTURAL | 7/22/2015 | | 8/19/2015 | | FAIL |
Carl Westfall
|
|
|
Dave Haugland
|
Routing PW Drainage | 7/23/2015 | | 8/6/2015 | | FAIL |
Jason C. Taylor
|
|
|
|
Routing PW Sewer Design | 7/23/2015 | | 8/6/2015 | | PASS |
Kyle S. Rosenmeyer
|
|
|
Sewer approved under separate Public Works project.
|
Routing - PLUMBING | 7/22/2015 | | 8/5/2015 | | FAIL |
Daryl Spivey
|
|
|
|
Routing PW Sewer Rating | 7/23/2015 | | 7/27/2015 | | PASS |
Jennifer Bruner
|
|
|
|
Routing - FIRE | 7/22/2015 | 7/22/2015 | 7/24/2015 | | PASS |
Katie Marron
|
|
|
Comments attached to case.
|
Routing - Addressing | 7/22/2015 | | 7/24/2015 | | PASS |
Emily Dixon
|
|
|
|
Routing - PUBLIC WORKS | 7/22/2015 | | 7/23/2015 | | PASS |
Jennifer Bruner
|
|
|
|
Routing - Design Review | 7/22/2015 | | 7/23/2015 | | PASS |
Josh Wilson
|
|
|
|
Routing PW Solid Waste | 7/23/2015 | | 7/23/2015 | | PASS |
Megan Durrell
|
|
|
|
Routing - PLANNING Land Div | 7/22/2015 | | 7/23/2015 | | PASS |
Dave Abo
|
|
|
|
Routing - MECHANICAL | 7/22/2015 | | 7/23/2015 | | PASS |
Troy James
|
|
|
|
Pending Assignment by TLW | 7/22/2015 | | 7/22/2015 | | DONE |
Tim L. Woodard
|
|
|
|
Routing - Erosion and Sediment | 7/22/2015 | | 7/22/2015 | | PASS |
Andy J. Long
|
|
|
|
Intake Approval | | | 7/20/2015 | | PASS |
|
|
|
|
Intake Approval | | | 6/25/2015 | | FAIL |
Carl Westfall
|
|
|
(6-23-15) Drawings submitted in ePlanReview.
(6-25-15) Please refer to the circled items on the plan intake checklist and resolve them as noted.
|
Application received | | | 4/9/2015 | | DONE |
|
|
|
Application submitted via PDS Online on Apr 9 2015 3:20PM
|
First Notice | | 12/14/2017 | | | |
|
|
|
|