Permit Information
Permit NumberBLD15-01601
StatusFinaled
Name PINNACLE BUILDERS INCORPORATED
Site Address 6887 W FAIRVIEW AVE
Project NameFairview Commercial Pad A
Customer Number 
ePlanReviewYes
Description
(FAIRVIEW COMMERCIAL PAD “A” - Shell and Core) Permit is to construct a 4,920 square foot Retail / Office Shell building. This building is constructed as a wood frame building and a concrete footing. Work includes: new foundation, new exterior walls, new mechanical, stubbing in plumbing into the building, site work, new wood frame exterior walls, new manufactured wood truss roof system, and new electrical (No lighting proposed). This building is not fire sprinklered. NOTE: additional energy code package of Lighting was selected; however, not installed at this time. The future tenants will have to meet the “Reduced Lighting Allowances”. **TLW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice5/17/20165/17/20166/10/2016 DONE
DetailsMike Jordan
Mailed 6-13-16
BLD-Final5/16/20165/17/20165/17/2016APASS
DetailsMike Jordan
call for access; Jason Phone #: ###-####
DOC - Permit Finaled5/17/20165/17/20165/17/2016PPASS
DetailsMike Jordan
Zoning Approval4/4/20164/4/20164/4/2016 PASS
DetailsJosh Wilson
FIRE-Final Inspection3/30/20163/31/20163/31/2016APASS
DetailsTroy Cobbley
Life safety passed. Address is on the free standing sign
BLD-Framing/Rough-in3/28/20163/29/20163/29/2016APASS
DetailsMike Jordan
Call for access - Jason Phone #: ###-####
Print Occupancy Form  3/18/2016 DONE
BLD-Framing/Rough-in3/15/20163/16/20163/16/2016APART
DetailsMike Jordan
Jason Phone #: ###-####. Framing ok. Needs to foam all penetrations in top plates. Correction notice posted.
BLD-Wall Bracing11/16/201511/17/201511/17/2015APASS
DetailsJim Sly
Travis Phone #: ###-####
OK to cover Ext.
BLD-Wall Bracing11/16/201511/16/201511/16/2015PNR
DetailsMike Jordan
Travis Phone #: ###-####. No one on site. called travis and left message noting that I was on my way. Waited at jobsite for approx. 45. min. No one on site except for stucco crew. Noted sheet rock cannot see the entirely assembly (WP 1330) I noted to travis that some sheetrock will need to removed to see aseembly. Will need to reschedule.
BLD-Wall Bracing11/13/201511/16/201511/16/2015ANH
DetailsMike Jordan
Travis Phone #: ###-####. No access to jobsite. No one here, gate locked. RESCHEDULED A PM INSPECTION.
BLD-Wall Bracing11/12/201511/13/201511/13/2015ANR
DetailsMike Jordan
Travis Phone #: ###-####. New details for exterior 1hr. walls not yet submitted and approved. Called to advise travis on what he needs to do.
BLD-Wall Bracing11/5/201511/9/201511/9/2015AFAIL
DetailsMike Jordan
Travis Phone #: ###-####. Detail procided by architect only provides 1hr. from the exterior side, 1hr. is required from both sides of exterior wall. Plan design shows that the parapet is to be constructed 2x framing to provide the required 1hr. construction on either side. in place construction used jack truss to provide parapet construction. Called travis to advise him of non compliance. Also spoke with plan review (Tim W. ) to discuss the non compliance. Architect and contractor to resubmit to plan review to show design change and details of an approved assembly to show compliance with the approved plans.
BLD-Wall Bracing11/4/201511/5/201511/4/2015ACANC
DetailsMike Jordan
Travis Phone #: ###-#### **CANCELED by contractor***
BLD-Wall Bracing10/29/201511/2/201511/2/2015AFAIL
DetailsMike Jordan
Travis Phone #: ###-####.. North and south wall shaer walls ok. Did note however that east and west walls are one construction to to proximity to property lines. Contractor to provide 1hr. construction on east and west walls per approved plan. Provide approved detail from architect showing the paprpet rating as well as soffitt? A correction notice was issued
BLD-Energy code compliance10/1/201510/1/201510/2/2015PPART
DetailsJim Sly
Rob Phone #: ###-####
Foundation Insulation OK
BLD-Footing9/23/20159/23/20159/23/2015PCANC
DetailsMike Jordan
Travis Phone #: ###-####
BLD-Footing9/23/20159/23/20159/23/2015PPASS
DetailsMike Jordan
Travis Phone #: ###-####
Issue PAID IN FULL permit  9/1/2015 DONE
DetailsChristina Prado
Inspection Record Card- Bld  9/1/2015 DONE
DetailsChristina Prado
OVERRIDE  8/31/2015  
Permit Ready to Issue  8/31/2015 DONE
DetailsChristina Prado
Need GC, RP & Revised certificate of value for issuance
PLANS/APPL TAKEN TO FRONT DESK  8/30/2015 DONE
Routing - PLAN CHECK7/27/2015 8/30/2015 PASS
DetailsTim L. Woodard
Plan assigned to (TLW)6/4/2015 8/30/2015 PASS
DetailsTim L. Woodard
1st Review Complete. TLW
Routing - Erosion and Sediment8/28/2015 8/28/2015 PASS
DetailsAndy J. Long
Plan designer submitted interim PD and will take course in October. ESC site map and narrative approved. Need to designate valid Responsble Person.
Routing Off Site - STRUCTURAL8/21/2015 8/28/2015 PASS
DetailsTim L. Woodard
Routing - Erosion and Sediment8/24/2015 8/24/2015 FAIL
DetailsEvan Jenkins
Plan Designer certification Expired. Obtain Interim PD Certification by paying the $10 fee, plus bring in verification you are registered for the next PD Cert Course for 4th ESC Review and Approval per our conversations. Evan Jenkins 794.3958
Routing - Erosion and Sediment8/18/2015 8/18/2015 FAIL
DetailsEvan Jenkins
Plan Designer certification Expired. Obtain Interim PD Certification by paying the $10 fee, plus bring in verification you are registered for the next PD Cert Course for 3rd ESC Review and Approval per our conversations. Evan Jenkins 794.3958
Routing Off Site - STRUCTURAL7/27/2015 8/17/2015 FAIL
DetailsTim L. Woodard
Routing - FIRE7/27/20157/27/20158/4/2015 PASS
DetailsKatie Marron
Revised report attached to case.
Routing - Erosion and Sediment7/27/2015 7/28/2015 FAIL
DetailsEvan Jenkins
Due to size, exceeding 600 SF (4,920+)SF, Full Erosion Control Narrative is Required to be submitted with your Erosion Control Site Map Per BCC 8-17. Evan Jenkins 794.3958
Plan resubmittals received  7/27/2015 DONE
Route to Impact Fee Review7/1/20157/4/20157/2/2015 PASS
DetailsCindy M. Gould
1st review completed  7/1/2015 DONE
Routing - PLAN CHECK6/4/2015 7/1/2015 FAIL
DetailsTim L. Woodard
Routing PW Environmental6/4/2015 7/1/2015 PASS
DetailsRick Christenson
Routing Off Site - STRUCTURAL6/4/2015 6/30/2015 FAIL
DetailsTim L. Woodard
Refer to Changemarks in E-Plan Review. TLW
Routing - PLANNING Land Div6/4/2015 6/10/2015 PASS
DetailsDave Abo
Parcel B of ROS 6906.
Routing - PLUMBING6/4/2015 6/8/2015 PASS
DetailsDaryl Spivey
per pland and ISPC
Routing - Design Review6/4/2015 6/8/2015 PASS
Details
Ok per DRH15-00023
Routing - FIRE6/4/2015 6/8/2015 FAIL
DetailsScott Arellano
Comments attached to plans and emailed to architect.
Routing PW Drainage6/4/2015 6/5/2015 PASS
DetailsBrian Murphy
pad phase 2 prvious city approval
Routing PW Sewer Rating6/4/2015 6/4/2015 PASS
DetailsJennifer Bruner
Routing - Addressing6/4/2015 6/4/2015 PASS
DetailsEmily Dixon
Routing - PUBLIC WORKS6/4/2015 6/4/2015 PASS
DetailsJennifer Bruner
In West Boise Sewer District, call ###-####
Routing - Erosion and Sediment6/4/2015 6/4/2015 FAIL
DetailsEvan Jenkins
Full ESC Narrative Required For Approval per BCC 8-17. Site Map looks good, but require a Narrative. Evan Jenkins 794.3958
Intake Approval  6/4/2015 PASS
Pending Assignment by TLW6/4/2015 6/4/2015 DONE
DetailsTim L. Woodard
Intake Approval  5/18/2015 FAIL
Ward,

A complete prescreen wasn't able to be conducted because the checklist was not availible; however, here are some items that stood out without having the checklist as a guide: 1) #502 Checklist, 2) Envelope Compliance needs to be 2012 IECC, 3) Provide the additional Special Inspections forms not just the cover sheet, 4) Planning Approvals, 5) Verification of legal lot form, 6) Drainage Calculations, 7) Cival sheets(Grading and Drainage Plans), 8) Soils report, 9) ESC Narritive, 10) Rotate and reupload all verticle plan sheets, 11) Mechanical Compliance Report is illedgible (Fix sheet and reupload), 12) Slab edge insulation must extend to top of slab, 13) Roof insulation must extend to verticle edge of envelope, and anything else that is on the checklist.

Best regards,

Tim
Application received  5/13/2015 DONE
Application submitted via PDS Online on May 13 2015 4:31PM